Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion

BACKGROUND: The aim of this study was to provide valid data for a plate-screw fixation model for fractured posterior-anterior columns of the acetabulum. MATERIAL/METHODS: Nineteen cadaveric bony hemi-pelvis specimens were obtained and 50 healthy adults were enrolled. The modified Stoppa approach and...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Yongqiang, Lin, Chuangxin, Zhang, Lifeng, Lin, Miaoxiong, Lai, Jianqiang, Cao, Shenglu, Peng, Geng, Feng, Kai, Yan, Ge, Cai, Daozhang, Wang, Gang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017690/
https://www.ncbi.nlm.nih.gov/pubmed/27584820
http://dx.doi.org/10.12659/MSM.896313
_version_ 1782452797983162368
author Xu, Yongqiang
Lin, Chuangxin
Zhang, Lifeng
Lin, Miaoxiong
Lai, Jianqiang
Cao, Shenglu
Peng, Geng
Feng, Kai
Yan, Ge
Cai, Daozhang
Wang, Gang
author_facet Xu, Yongqiang
Lin, Chuangxin
Zhang, Lifeng
Lin, Miaoxiong
Lai, Jianqiang
Cao, Shenglu
Peng, Geng
Feng, Kai
Yan, Ge
Cai, Daozhang
Wang, Gang
author_sort Xu, Yongqiang
collection PubMed
description BACKGROUND: The aim of this study was to provide valid data for a plate-screw fixation model for fractured posterior-anterior columns of the acetabulum. MATERIAL/METHODS: Nineteen cadaveric bony hemi-pelvis specimens were obtained and 50 healthy adults were enrolled. The modified Stoppa approach and computed tomography (CT) imaging were used to collect the measured parameter data of the module. RESULTS: The measured parameter data were as follows: OP, 0.96±0.32 cm in females and 0.92±0.16 cm in males (P>0.05); PI, 0.98±0.28 cm in females, and 0.75±0.23 cm in males (P>0.05); ∠θ, 59.68°±6.28° in females and 56.75°±3.22° in males (P>0.05); and ∠ϕ, 41.27°±2.76° in females and 34.31°±2.78° in males (P<0.05). The corresponding CT image data were as follows: PI, 1.08±0.22 cm in females and 0.85±0.27 cm in males (P>0.05); OP, 1.06±0.29 cm in females and 1.12±0.24 cm in males (P>0.05); ∠θ, 55.33°±4.00° in females and 55. 50°±3.43° in males (P>0.05); and ∠ϕ was 39.21°±2.45°in females and 35.58°±2.31°in males (P<0.05). No significant difference with respect to sex and side existed between specimens and healthy adults (P>0.05). CONCLUSIONS: The measured parameter data obtained in healthy adults and cadaveric specimens provided an anatomic basis for the designation of the guide module, and thus confirmed the accuracy and safety of screw placement in fractured columns of the acetabulum.
format Online
Article
Text
id pubmed-5017690
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-50176902016-09-20 Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion Xu, Yongqiang Lin, Chuangxin Zhang, Lifeng Lin, Miaoxiong Lai, Jianqiang Cao, Shenglu Peng, Geng Feng, Kai Yan, Ge Cai, Daozhang Wang, Gang Med Sci Monit Clinical Research BACKGROUND: The aim of this study was to provide valid data for a plate-screw fixation model for fractured posterior-anterior columns of the acetabulum. MATERIAL/METHODS: Nineteen cadaveric bony hemi-pelvis specimens were obtained and 50 healthy adults were enrolled. The modified Stoppa approach and computed tomography (CT) imaging were used to collect the measured parameter data of the module. RESULTS: The measured parameter data were as follows: OP, 0.96±0.32 cm in females and 0.92±0.16 cm in males (P>0.05); PI, 0.98±0.28 cm in females, and 0.75±0.23 cm in males (P>0.05); ∠θ, 59.68°±6.28° in females and 56.75°±3.22° in males (P>0.05); and ∠ϕ, 41.27°±2.76° in females and 34.31°±2.78° in males (P<0.05). The corresponding CT image data were as follows: PI, 1.08±0.22 cm in females and 0.85±0.27 cm in males (P>0.05); OP, 1.06±0.29 cm in females and 1.12±0.24 cm in males (P>0.05); ∠θ, 55.33°±4.00° in females and 55. 50°±3.43° in males (P>0.05); and ∠ϕ was 39.21°±2.45°in females and 35.58°±2.31°in males (P<0.05). No significant difference with respect to sex and side existed between specimens and healthy adults (P>0.05). CONCLUSIONS: The measured parameter data obtained in healthy adults and cadaveric specimens provided an anatomic basis for the designation of the guide module, and thus confirmed the accuracy and safety of screw placement in fractured columns of the acetabulum. International Scientific Literature, Inc. 2016-09-01 /pmc/articles/PMC5017690/ /pubmed/27584820 http://dx.doi.org/10.12659/MSM.896313 Text en © Med Sci Monit, 2016 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
spellingShingle Clinical Research
Xu, Yongqiang
Lin, Chuangxin
Zhang, Lifeng
Lin, Miaoxiong
Lai, Jianqiang
Cao, Shenglu
Peng, Geng
Feng, Kai
Yan, Ge
Cai, Daozhang
Wang, Gang
Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion
title Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion
title_full Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion
title_fullStr Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion
title_full_unstemmed Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion
title_short Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion
title_sort anterograde fixation module for posterior acetabular column fracture: computer-assisted determination of optimal entry point, angle, and length for screw insertion
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5017690/
https://www.ncbi.nlm.nih.gov/pubmed/27584820
http://dx.doi.org/10.12659/MSM.896313
work_keys_str_mv AT xuyongqiang anterogradefixationmoduleforposterioracetabularcolumnfracturecomputerassisteddeterminationofoptimalentrypointangleandlengthforscrewinsertion
AT linchuangxin anterogradefixationmoduleforposterioracetabularcolumnfracturecomputerassisteddeterminationofoptimalentrypointangleandlengthforscrewinsertion
AT zhanglifeng anterogradefixationmoduleforposterioracetabularcolumnfracturecomputerassisteddeterminationofoptimalentrypointangleandlengthforscrewinsertion
AT linmiaoxiong anterogradefixationmoduleforposterioracetabularcolumnfracturecomputerassisteddeterminationofoptimalentrypointangleandlengthforscrewinsertion
AT laijianqiang anterogradefixationmoduleforposterioracetabularcolumnfracturecomputerassisteddeterminationofoptimalentrypointangleandlengthforscrewinsertion
AT caoshenglu anterogradefixationmoduleforposterioracetabularcolumnfracturecomputerassisteddeterminationofoptimalentrypointangleandlengthforscrewinsertion
AT penggeng anterogradefixationmoduleforposterioracetabularcolumnfracturecomputerassisteddeterminationofoptimalentrypointangleandlengthforscrewinsertion
AT fengkai anterogradefixationmoduleforposterioracetabularcolumnfracturecomputerassisteddeterminationofoptimalentrypointangleandlengthforscrewinsertion
AT yange anterogradefixationmoduleforposterioracetabularcolumnfracturecomputerassisteddeterminationofoptimalentrypointangleandlengthforscrewinsertion
AT caidaozhang anterogradefixationmoduleforposterioracetabularcolumnfracturecomputerassisteddeterminationofoptimalentrypointangleandlengthforscrewinsertion
AT wanggang anterogradefixationmoduleforposterioracetabularcolumnfracturecomputerassisteddeterminationofoptimalentrypointangleandlengthforscrewinsertion