Cargando…
A novel artificial tissue simulator for endoscopic submucosal resection training – a pilot study
BACKGROUND: We developed a novel artificial simulator for endoscopic submucosal dissection (ESD) as a bridge between instructional videos and animal tissue training and aimed to evaluate the feasibility of using an artificial tissue model in ESD training. METHODS: Eight gastroenterology fellows from...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5018178/ https://www.ncbi.nlm.nih.gov/pubmed/27612455 http://dx.doi.org/10.1186/s12876-016-0529-x |
_version_ | 1782452872045133824 |
---|---|
author | Chen, Ming-Jen Wang, Horng-Yuan Chang, Chen-Wang Lin, Ching-Chung Chen, Chih-Jen Chu, Cheng-Hsin Wang, Tsang-En Shih, Shou-Chuan |
author_facet | Chen, Ming-Jen Wang, Horng-Yuan Chang, Chen-Wang Lin, Ching-Chung Chen, Chih-Jen Chu, Cheng-Hsin Wang, Tsang-En Shih, Shou-Chuan |
author_sort | Chen, Ming-Jen |
collection | PubMed |
description | BACKGROUND: We developed a novel artificial simulator for endoscopic submucosal dissection (ESD) as a bridge between instructional videos and animal tissue training and aimed to evaluate the feasibility of using an artificial tissue model in ESD training. METHODS: Eight gastroenterology fellows from one medical center were enrolled in this ESD training program. Before and after the simulator training, attendees indicated on a 5-point scale the degree of difficulty in performing the following procedures: lesion marking, mucosal pre-cutting, circumferential incision, submucosal dissection, and hemostasis. After the simulator training, the participants completed a questionnaire regarding their opinions on the degree of realism and the feasibility of using this model for training. RESULTS: After watching an instructional video, attendees felt that the most difficult techniques were submucosal dissection and hemostasis. After using the artificial tissue simulator model, the attendees felt more confident in performing performing lesion marking (p = 0.026) and submucosal dissection (p = 0.037). However, they still felt that hemostasis was the most difficult techniques to master. Overall, the attendees thought the simulator was realistic in simulated lesion marking and its use was feasible for simulated lesion marking and submucosal dissection. CONCLUSION: Our pilot study shows the feasibility of using a novel artificial tissue in performing ESD and we believe that the artificial tissue simulator acts well as a bridge between instructional videos and animal model training. The model is reusable and inexpensive, and could disseminate the techniques of the ESD more easily and quickly. |
format | Online Article Text |
id | pubmed-5018178 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-50181782016-09-11 A novel artificial tissue simulator for endoscopic submucosal resection training – a pilot study Chen, Ming-Jen Wang, Horng-Yuan Chang, Chen-Wang Lin, Ching-Chung Chen, Chih-Jen Chu, Cheng-Hsin Wang, Tsang-En Shih, Shou-Chuan BMC Gastroenterol Research Article BACKGROUND: We developed a novel artificial simulator for endoscopic submucosal dissection (ESD) as a bridge between instructional videos and animal tissue training and aimed to evaluate the feasibility of using an artificial tissue model in ESD training. METHODS: Eight gastroenterology fellows from one medical center were enrolled in this ESD training program. Before and after the simulator training, attendees indicated on a 5-point scale the degree of difficulty in performing the following procedures: lesion marking, mucosal pre-cutting, circumferential incision, submucosal dissection, and hemostasis. After the simulator training, the participants completed a questionnaire regarding their opinions on the degree of realism and the feasibility of using this model for training. RESULTS: After watching an instructional video, attendees felt that the most difficult techniques were submucosal dissection and hemostasis. After using the artificial tissue simulator model, the attendees felt more confident in performing performing lesion marking (p = 0.026) and submucosal dissection (p = 0.037). However, they still felt that hemostasis was the most difficult techniques to master. Overall, the attendees thought the simulator was realistic in simulated lesion marking and its use was feasible for simulated lesion marking and submucosal dissection. CONCLUSION: Our pilot study shows the feasibility of using a novel artificial tissue in performing ESD and we believe that the artificial tissue simulator acts well as a bridge between instructional videos and animal model training. The model is reusable and inexpensive, and could disseminate the techniques of the ESD more easily and quickly. BioMed Central 2016-09-10 /pmc/articles/PMC5018178/ /pubmed/27612455 http://dx.doi.org/10.1186/s12876-016-0529-x Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Chen, Ming-Jen Wang, Horng-Yuan Chang, Chen-Wang Lin, Ching-Chung Chen, Chih-Jen Chu, Cheng-Hsin Wang, Tsang-En Shih, Shou-Chuan A novel artificial tissue simulator for endoscopic submucosal resection training – a pilot study |
title | A novel artificial tissue simulator for endoscopic submucosal resection training – a pilot study |
title_full | A novel artificial tissue simulator for endoscopic submucosal resection training – a pilot study |
title_fullStr | A novel artificial tissue simulator for endoscopic submucosal resection training – a pilot study |
title_full_unstemmed | A novel artificial tissue simulator for endoscopic submucosal resection training – a pilot study |
title_short | A novel artificial tissue simulator for endoscopic submucosal resection training – a pilot study |
title_sort | novel artificial tissue simulator for endoscopic submucosal resection training – a pilot study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5018178/ https://www.ncbi.nlm.nih.gov/pubmed/27612455 http://dx.doi.org/10.1186/s12876-016-0529-x |
work_keys_str_mv | AT chenmingjen anovelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT wanghorngyuan anovelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT changchenwang anovelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT linchingchung anovelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT chenchihjen anovelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT chuchenghsin anovelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT wangtsangen anovelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT shihshouchuan anovelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT chenmingjen novelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT wanghorngyuan novelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT changchenwang novelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT linchingchung novelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT chenchihjen novelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT chuchenghsin novelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT wangtsangen novelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy AT shihshouchuan novelartificialtissuesimulatorforendoscopicsubmucosalresectiontrainingapilotstudy |