Cargando…
Y-configured metallic stent combined with (125)I seed strands cavity brachytherapy for a patient with type IV Klatskin tumor
We report a case in an inoperable patient with type IV Klatskin tumor treated by the use of a novel, two piece, Y-configured self-expandable metallic stent (SEMS) combined with two (125)I seed strands via bilateral approach. The placement of the Y-shaped SEMS was successful and resulted in adequate...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5018522/ https://www.ncbi.nlm.nih.gov/pubmed/27648091 http://dx.doi.org/10.5114/jcb.2016.61704 |
_version_ | 1782452922789920768 |
---|---|
author | Dechao, Jiao Han, Xinwei Yanli, Wang Zhen, Li |
author_facet | Dechao, Jiao Han, Xinwei Yanli, Wang Zhen, Li |
author_sort | Dechao, Jiao |
collection | PubMed |
description | We report a case in an inoperable patient with type IV Klatskin tumor treated by the use of a novel, two piece, Y-configured self-expandable metallic stent (SEMS) combined with two (125)I seed strands via bilateral approach. The placement of the Y-shaped SEMS was successful and resulted in adequate biliary drainage. After 2 months of intraluminal brachytherapy (ILBT), both (125)I seed strands and temporary drainage catheter were removed after patency of the expanded stents was confirmed by the cholangiogram. This technique was feasible and could be considered for the treatment of patients with Bismuth type IV Klatskin tumors. |
format | Online Article Text |
id | pubmed-5018522 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-50185222016-09-19 Y-configured metallic stent combined with (125)I seed strands cavity brachytherapy for a patient with type IV Klatskin tumor Dechao, Jiao Han, Xinwei Yanli, Wang Zhen, Li J Contemp Brachytherapy Case Report We report a case in an inoperable patient with type IV Klatskin tumor treated by the use of a novel, two piece, Y-configured self-expandable metallic stent (SEMS) combined with two (125)I seed strands via bilateral approach. The placement of the Y-shaped SEMS was successful and resulted in adequate biliary drainage. After 2 months of intraluminal brachytherapy (ILBT), both (125)I seed strands and temporary drainage catheter were removed after patency of the expanded stents was confirmed by the cholangiogram. This technique was feasible and could be considered for the treatment of patients with Bismuth type IV Klatskin tumors. Termedia Publishing House 2016-08-09 2016-08 /pmc/articles/PMC5018522/ /pubmed/27648091 http://dx.doi.org/10.5114/jcb.2016.61704 Text en Copyright: © 2016 Termedia Sp. z o. o. http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license. |
spellingShingle | Case Report Dechao, Jiao Han, Xinwei Yanli, Wang Zhen, Li Y-configured metallic stent combined with (125)I seed strands cavity brachytherapy for a patient with type IV Klatskin tumor |
title | Y-configured metallic stent combined with (125)I seed strands cavity brachytherapy for a patient with type IV Klatskin tumor |
title_full | Y-configured metallic stent combined with (125)I seed strands cavity brachytherapy for a patient with type IV Klatskin tumor |
title_fullStr | Y-configured metallic stent combined with (125)I seed strands cavity brachytherapy for a patient with type IV Klatskin tumor |
title_full_unstemmed | Y-configured metallic stent combined with (125)I seed strands cavity brachytherapy for a patient with type IV Klatskin tumor |
title_short | Y-configured metallic stent combined with (125)I seed strands cavity brachytherapy for a patient with type IV Klatskin tumor |
title_sort | y-configured metallic stent combined with (125)i seed strands cavity brachytherapy for a patient with type iv klatskin tumor |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5018522/ https://www.ncbi.nlm.nih.gov/pubmed/27648091 http://dx.doi.org/10.5114/jcb.2016.61704 |
work_keys_str_mv | AT dechaojiao yconfiguredmetallicstentcombinedwith125iseedstrandscavitybrachytherapyforapatientwithtypeivklatskintumor AT hanxinwei yconfiguredmetallicstentcombinedwith125iseedstrandscavitybrachytherapyforapatientwithtypeivklatskintumor AT yanliwang yconfiguredmetallicstentcombinedwith125iseedstrandscavitybrachytherapyforapatientwithtypeivklatskintumor AT zhenli yconfiguredmetallicstentcombinedwith125iseedstrandscavitybrachytherapyforapatientwithtypeivklatskintumor |