PURPOSE: To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms across multi-centers and propose a diagnostic reference level (DRL). MATERIALS AND METHODS: We studied a sample of 490 diagnostic and 371 therapeutic procedures for intracranial aneurysm...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Interventional Neuroradiology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5018552/ https://www.ncbi.nlm.nih.gov/pubmed/27621943 http://dx.doi.org/10.5469/neuroint.2016.11.2.78 |
_version_ | 1782452929835302912 |
---|---|
author | Ihn, Yon Kwon Kim, Bum-Soo Byun, Jun Soo Suh, Sang Hyun Won, Yoo Dong Lee, Deok Hee Kim, Byung Moon Kim, Young Soo Jeon, Pyong Ryu, Chang-Woo Suh, Sang-il Choi, Dae Seob Choi, See Sung Choi, Jin Wook Chang, Hyuk Won Lee, Jae-Wook Kim, Sang Heum Lee, Young Jun Shin, Shang Hun Lim, Soo Mee Yoon, Woong Jeong, Hae Woong Han, Moon Hee |
author_facet | Ihn, Yon Kwon Kim, Bum-Soo Byun, Jun Soo Suh, Sang Hyun Won, Yoo Dong Lee, Deok Hee Kim, Byung Moon Kim, Young Soo Jeon, Pyong Ryu, Chang-Woo Suh, Sang-il Choi, Dae Seob Choi, See Sung Choi, Jin Wook Chang, Hyuk Won Lee, Jae-Wook Kim, Sang Heum Lee, Young Jun Shin, Shang Hun Lim, Soo Mee Yoon, Woong Jeong, Hae Woong Han, Moon Hee |
author_sort | Ihn, Yon Kwon |
collection | PubMed |
description | PURPOSE: To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms across multi-centers and propose a diagnostic reference level (DRL). MATERIALS AND METHODS: We studied a sample of 490 diagnostic and 371 therapeutic procedures for intracranial aneurysms, which were performed at 23 hospitals in Korea in 2015. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time and total angiographic image frames were obtained and analyzed. RESULTS: Total mean DAP, CAK, fluoroscopy time, and total angiographic image frames were 106.2 ± 66.4 Gy-cm(2), 697.1 ± 473.7 mGy, 9.7 ± 6.5 minutes, 241.5 ± 116.6 frames for diagnostic procedures, 218.8 ± 164.3 Gy-cm(2), 3365.7 ± 2205.8 mGy, 51.5 ± 31.1 minutes, 443.5 ± 270.7 frames for therapeutic procedures, respectively. For diagnostic procedure, the third quartiles for DRLs were 144.2 Gy-cm(2) for DAP, 921.1 mGy for CAK, 12.2 minutes for fluoroscopy times and 286.5 for number of image frames, respectively. For therapeutic procedures, the third quartiles for DRLs were 271.0 Gy-cm(2) for DAP, 4471.3 mGy for CAK, 64.7 minutes for fluoroscopy times and 567.3 for number of image frames, respectively. On average, rotational angiography was used 1.5 ± 0.7 times/session (range, 0-4; n=490) for diagnostic procedures and 1.6 ± 1.2 times/session (range, 0-4; n=368) for therapeutic procedures, respectively. CONCLUSION: Radiation dose as measured by DAP, fluoroscopy time and image frames were lower in our patients compared to another study regarding cerebral angiography, and DAP was lower with fewer angiographic image frames for therapeutic procedures. Proposed DRLs can be used for quality assurance and patient safety in diagnostic and therapeutic procedures. |
format | Online Article Text |
id | pubmed-5018552 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Korean Society of Interventional Neuroradiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-50185522016-09-12 Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study Ihn, Yon Kwon Kim, Bum-Soo Byun, Jun Soo Suh, Sang Hyun Won, Yoo Dong Lee, Deok Hee Kim, Byung Moon Kim, Young Soo Jeon, Pyong Ryu, Chang-Woo Suh, Sang-il Choi, Dae Seob Choi, See Sung Choi, Jin Wook Chang, Hyuk Won Lee, Jae-Wook Kim, Sang Heum Lee, Young Jun Shin, Shang Hun Lim, Soo Mee Yoon, Woong Jeong, Hae Woong Han, Moon Hee Neurointervention Original Paper PURPOSE: To assess patient radiation doses during cerebral angiography and embolization of intracranial aneurysms across multi-centers and propose a diagnostic reference level (DRL). MATERIALS AND METHODS: We studied a sample of 490 diagnostic and 371 therapeutic procedures for intracranial aneurysms, which were performed at 23 hospitals in Korea in 2015. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time and total angiographic image frames were obtained and analyzed. RESULTS: Total mean DAP, CAK, fluoroscopy time, and total angiographic image frames were 106.2 ± 66.4 Gy-cm(2), 697.1 ± 473.7 mGy, 9.7 ± 6.5 minutes, 241.5 ± 116.6 frames for diagnostic procedures, 218.8 ± 164.3 Gy-cm(2), 3365.7 ± 2205.8 mGy, 51.5 ± 31.1 minutes, 443.5 ± 270.7 frames for therapeutic procedures, respectively. For diagnostic procedure, the third quartiles for DRLs were 144.2 Gy-cm(2) for DAP, 921.1 mGy for CAK, 12.2 minutes for fluoroscopy times and 286.5 for number of image frames, respectively. For therapeutic procedures, the third quartiles for DRLs were 271.0 Gy-cm(2) for DAP, 4471.3 mGy for CAK, 64.7 minutes for fluoroscopy times and 567.3 for number of image frames, respectively. On average, rotational angiography was used 1.5 ± 0.7 times/session (range, 0-4; n=490) for diagnostic procedures and 1.6 ± 1.2 times/session (range, 0-4; n=368) for therapeutic procedures, respectively. CONCLUSION: Radiation dose as measured by DAP, fluoroscopy time and image frames were lower in our patients compared to another study regarding cerebral angiography, and DAP was lower with fewer angiographic image frames for therapeutic procedures. Proposed DRLs can be used for quality assurance and patient safety in diagnostic and therapeutic procedures. Korean Society of Interventional Neuroradiology 2016-09 2016-09-03 /pmc/articles/PMC5018552/ /pubmed/27621943 http://dx.doi.org/10.5469/neuroint.2016.11.2.78 Text en Copyright © 2016 Korean Society of Interventional Neuroradiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Paper Ihn, Yon Kwon Kim, Bum-Soo Byun, Jun Soo Suh, Sang Hyun Won, Yoo Dong Lee, Deok Hee Kim, Byung Moon Kim, Young Soo Jeon, Pyong Ryu, Chang-Woo Suh, Sang-il Choi, Dae Seob Choi, See Sung Choi, Jin Wook Chang, Hyuk Won Lee, Jae-Wook Kim, Sang Heum Lee, Young Jun Shin, Shang Hun Lim, Soo Mee Yoon, Woong Jeong, Hae Woong Han, Moon Hee Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study |
title | Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study |
title_full | Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study |
title_fullStr | Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study |
title_full_unstemmed | Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study |
title_short | Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study |
title_sort | patient radiation exposure during diagnostic and therapeutic procedures for intracranial aneurysms: a multicenter study |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5018552/ https://www.ncbi.nlm.nih.gov/pubmed/27621943 http://dx.doi.org/10.5469/neuroint.2016.11.2.78 |
work_keys_str_mv | AT ihnyonkwon patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT kimbumsoo patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT byunjunsoo patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT suhsanghyun patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT wonyoodong patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT leedeokhee patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT kimbyungmoon patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT kimyoungsoo patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT jeonpyong patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT ryuchangwoo patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT suhsangil patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT choidaeseob patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT choiseesung patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT choijinwook patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT changhyukwon patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT leejaewook patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT kimsangheum patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT leeyoungjun patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT shinshanghun patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT limsoomee patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT yoonwoong patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT jeonghaewoong patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy AT hanmoonhee patientradiationexposureduringdiagnosticandtherapeuticproceduresforintracranialaneurysmsamulticenterstudy |