Cargando…

Lens density measurements by two independent psychophysical techniques

BACKGROUND: Cataract, a leading cause of vision impairment, is due to the lens becoming excessively optically dense. Change in the lens optical density (LOD) could be a useful indicator of incipient nuclear cataract and would necessitate the development of accurate measurement techniques. Mapcat sf™...

Descripción completa

Detalles Bibliográficos
Autores principales: Mukherjee, Anirbaan, Bone, Richard A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5018944/
https://www.ncbi.nlm.nih.gov/pubmed/27622189
http://dx.doi.org/10.1186/s40662-016-0054-6
_version_ 1782452985813532672
author Mukherjee, Anirbaan
Bone, Richard A.
author_facet Mukherjee, Anirbaan
Bone, Richard A.
author_sort Mukherjee, Anirbaan
collection PubMed
description BACKGROUND: Cataract, a leading cause of vision impairment, is due to the lens becoming excessively optically dense. Change in the lens optical density (LOD) could be a useful indicator of incipient nuclear cataract and would necessitate the development of accurate measurement techniques. Mapcat sf™ is a heterochromatic flicker photometer for measuring macular pigment optical density (MPOD) under photopic conditions. In the process, it also measures LOD that is needed in the calculation of MPOD. LOD is then converted by the instrument to “lens equivalent age” (LEA). However, varying cone photoreceptor ratios among individuals could affect the LEA measurement. Scotopic vision is mediated by rod photoreceptors; therefore, LEA measurement under scotopic conditions potentially provides a reliable standard for assessing other methods. The study was conducted to test the level of agreement between the LEA data obtained under photopic and scotopic conditions for a sample population. We also comment on factors that might contribute to any disagreement. METHODS: LEAs were obtained by Mapcat sf for 25 subjects and compared with those obtained under absolute scotopic threshold conditions. RESULTS: The mean scotopic LEA for the subjects was 2.7 years higher than the mean photopic LEA, but this difference was not statistically significant. Measurements by the two methods were reasonably correlated (r(2) = 0.59, p < 0.0001). Significant individual differences in LEA by the two methods were found for six of the 25 subjects. Although our calculations included a standard long- to medium-wavelength-sensitive cone ratio, we found that different ratios could be found that rendered the differences in LEA insignificant for two of these six subjects. Variability in pupil diameter during scotopic measurements was considered another potential source of discrepancy between LEAs by the two methods. CONCLUSION: The absolute threshold technique, with long adaptation times, is probably impractical for routine lens density measurement, whereas Mapcat sf provided a rapid, straightforward test that may find its application in optometric/ophthalmic practice.
format Online
Article
Text
id pubmed-5018944
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-50189442016-09-13 Lens density measurements by two independent psychophysical techniques Mukherjee, Anirbaan Bone, Richard A. Eye Vis (Lond) Research BACKGROUND: Cataract, a leading cause of vision impairment, is due to the lens becoming excessively optically dense. Change in the lens optical density (LOD) could be a useful indicator of incipient nuclear cataract and would necessitate the development of accurate measurement techniques. Mapcat sf™ is a heterochromatic flicker photometer for measuring macular pigment optical density (MPOD) under photopic conditions. In the process, it also measures LOD that is needed in the calculation of MPOD. LOD is then converted by the instrument to “lens equivalent age” (LEA). However, varying cone photoreceptor ratios among individuals could affect the LEA measurement. Scotopic vision is mediated by rod photoreceptors; therefore, LEA measurement under scotopic conditions potentially provides a reliable standard for assessing other methods. The study was conducted to test the level of agreement between the LEA data obtained under photopic and scotopic conditions for a sample population. We also comment on factors that might contribute to any disagreement. METHODS: LEAs were obtained by Mapcat sf for 25 subjects and compared with those obtained under absolute scotopic threshold conditions. RESULTS: The mean scotopic LEA for the subjects was 2.7 years higher than the mean photopic LEA, but this difference was not statistically significant. Measurements by the two methods were reasonably correlated (r(2) = 0.59, p < 0.0001). Significant individual differences in LEA by the two methods were found for six of the 25 subjects. Although our calculations included a standard long- to medium-wavelength-sensitive cone ratio, we found that different ratios could be found that rendered the differences in LEA insignificant for two of these six subjects. Variability in pupil diameter during scotopic measurements was considered another potential source of discrepancy between LEAs by the two methods. CONCLUSION: The absolute threshold technique, with long adaptation times, is probably impractical for routine lens density measurement, whereas Mapcat sf provided a rapid, straightforward test that may find its application in optometric/ophthalmic practice. BioMed Central 2016-09-12 /pmc/articles/PMC5018944/ /pubmed/27622189 http://dx.doi.org/10.1186/s40662-016-0054-6 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Mukherjee, Anirbaan
Bone, Richard A.
Lens density measurements by two independent psychophysical techniques
title Lens density measurements by two independent psychophysical techniques
title_full Lens density measurements by two independent psychophysical techniques
title_fullStr Lens density measurements by two independent psychophysical techniques
title_full_unstemmed Lens density measurements by two independent psychophysical techniques
title_short Lens density measurements by two independent psychophysical techniques
title_sort lens density measurements by two independent psychophysical techniques
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5018944/
https://www.ncbi.nlm.nih.gov/pubmed/27622189
http://dx.doi.org/10.1186/s40662-016-0054-6
work_keys_str_mv AT mukherjeeanirbaan lensdensitymeasurementsbytwoindependentpsychophysicaltechniques
AT bonericharda lensdensitymeasurementsbytwoindependentpsychophysicaltechniques