Cargando…

Measurement of eye lens dose for Varian On-Board Imaging with different cone-beam computed tomography acquisition techniques

The objective of this work was to measure patient eye lens dose for different cone-beam computed tomography (CBCT) acquisition protocols of Varian's On-Board Imaging (OBI) system using optically stimulated luminescence dosimeter (OSLD) and to study the variation in eye lens dose with patient ge...

Descripción completa

Detalles Bibliográficos
Autores principales: Deshpande, Sudesh, Dhote, Deepak, Thakur, Kalpna, Pawar, Amol, Kumar, Rajesh, Kumar, Munish, Kulkarni, M. S., Sharma, S. D., Kannan, V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5019036/
https://www.ncbi.nlm.nih.gov/pubmed/27651564
http://dx.doi.org/10.4103/0971-6203.189481
_version_ 1782452998260129792
author Deshpande, Sudesh
Dhote, Deepak
Thakur, Kalpna
Pawar, Amol
Kumar, Rajesh
Kumar, Munish
Kulkarni, M. S.
Sharma, S. D.
Kannan, V.
author_facet Deshpande, Sudesh
Dhote, Deepak
Thakur, Kalpna
Pawar, Amol
Kumar, Rajesh
Kumar, Munish
Kulkarni, M. S.
Sharma, S. D.
Kannan, V.
author_sort Deshpande, Sudesh
collection PubMed
description The objective of this work was to measure patient eye lens dose for different cone-beam computed tomography (CBCT) acquisition protocols of Varian's On-Board Imaging (OBI) system using optically stimulated luminescence dosimeter (OSLD) and to study the variation in eye lens dose with patient geometry and distance of isocenter to the eye lens. During the experimental measurements, OSLD was placed on the patient between the eyebrows of both eyes in line of nose during CBCT image acquisition to measure eye lens doses. The eye lens dose measurements were carried out for three different cone-beam acquisition protocols (standard dose head, low-dose head [LDH], and high-quality head [HQH]) of Varian OBI. Measured doses were correlated with patient geometry and distance between isocenter and eye lens. Measured eye lens doses for standard head and HQH protocols were in the range of 1.8–3.2 mGy and 4.5–9.9 mGy, respectively. However, the measured eye lens dose for the LDH protocol was in the range of 0.3–0.7 mGy. The measured data indicate that eye lens dose to patient depends on the selected imaging protocol. It was also observed that eye lens dose does not depend on patient geometry but strongly depends on distance between eye lens and treatment field isocenter. However, undoubted advantages of imaging system should not be counterbalanced by inappropriate selection of imaging protocol, especially for very intense imaging protocol.
format Online
Article
Text
id pubmed-5019036
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-50190362016-09-20 Measurement of eye lens dose for Varian On-Board Imaging with different cone-beam computed tomography acquisition techniques Deshpande, Sudesh Dhote, Deepak Thakur, Kalpna Pawar, Amol Kumar, Rajesh Kumar, Munish Kulkarni, M. S. Sharma, S. D. Kannan, V. J Med Phys Original Article The objective of this work was to measure patient eye lens dose for different cone-beam computed tomography (CBCT) acquisition protocols of Varian's On-Board Imaging (OBI) system using optically stimulated luminescence dosimeter (OSLD) and to study the variation in eye lens dose with patient geometry and distance of isocenter to the eye lens. During the experimental measurements, OSLD was placed on the patient between the eyebrows of both eyes in line of nose during CBCT image acquisition to measure eye lens doses. The eye lens dose measurements were carried out for three different cone-beam acquisition protocols (standard dose head, low-dose head [LDH], and high-quality head [HQH]) of Varian OBI. Measured doses were correlated with patient geometry and distance between isocenter and eye lens. Measured eye lens doses for standard head and HQH protocols were in the range of 1.8–3.2 mGy and 4.5–9.9 mGy, respectively. However, the measured eye lens dose for the LDH protocol was in the range of 0.3–0.7 mGy. The measured data indicate that eye lens dose to patient depends on the selected imaging protocol. It was also observed that eye lens dose does not depend on patient geometry but strongly depends on distance between eye lens and treatment field isocenter. However, undoubted advantages of imaging system should not be counterbalanced by inappropriate selection of imaging protocol, especially for very intense imaging protocol. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC5019036/ /pubmed/27651564 http://dx.doi.org/10.4103/0971-6203.189481 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Deshpande, Sudesh
Dhote, Deepak
Thakur, Kalpna
Pawar, Amol
Kumar, Rajesh
Kumar, Munish
Kulkarni, M. S.
Sharma, S. D.
Kannan, V.
Measurement of eye lens dose for Varian On-Board Imaging with different cone-beam computed tomography acquisition techniques
title Measurement of eye lens dose for Varian On-Board Imaging with different cone-beam computed tomography acquisition techniques
title_full Measurement of eye lens dose for Varian On-Board Imaging with different cone-beam computed tomography acquisition techniques
title_fullStr Measurement of eye lens dose for Varian On-Board Imaging with different cone-beam computed tomography acquisition techniques
title_full_unstemmed Measurement of eye lens dose for Varian On-Board Imaging with different cone-beam computed tomography acquisition techniques
title_short Measurement of eye lens dose for Varian On-Board Imaging with different cone-beam computed tomography acquisition techniques
title_sort measurement of eye lens dose for varian on-board imaging with different cone-beam computed tomography acquisition techniques
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5019036/
https://www.ncbi.nlm.nih.gov/pubmed/27651564
http://dx.doi.org/10.4103/0971-6203.189481
work_keys_str_mv AT deshpandesudesh measurementofeyelensdoseforvarianonboardimagingwithdifferentconebeamcomputedtomographyacquisitiontechniques
AT dhotedeepak measurementofeyelensdoseforvarianonboardimagingwithdifferentconebeamcomputedtomographyacquisitiontechniques
AT thakurkalpna measurementofeyelensdoseforvarianonboardimagingwithdifferentconebeamcomputedtomographyacquisitiontechniques
AT pawaramol measurementofeyelensdoseforvarianonboardimagingwithdifferentconebeamcomputedtomographyacquisitiontechniques
AT kumarrajesh measurementofeyelensdoseforvarianonboardimagingwithdifferentconebeamcomputedtomographyacquisitiontechniques
AT kumarmunish measurementofeyelensdoseforvarianonboardimagingwithdifferentconebeamcomputedtomographyacquisitiontechniques
AT kulkarnims measurementofeyelensdoseforvarianonboardimagingwithdifferentconebeamcomputedtomographyacquisitiontechniques
AT sharmasd measurementofeyelensdoseforvarianonboardimagingwithdifferentconebeamcomputedtomographyacquisitiontechniques
AT kannanv measurementofeyelensdoseforvarianonboardimagingwithdifferentconebeamcomputedtomographyacquisitiontechniques