Cargando…

Development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis

BACKGROUND: Cystic echinococcosis (CE) or hydatidosis, caused by the larval stage of Echinococcus granulosus (EG)-complex, is a neglected parasitic disease of public health importance. The disease is endemic in many African and Mediterranean countries including the Sudan. The objective of the presen...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahmed, Mohamed E., Eldigail, Mawahib H., Elamin, Fatima M., Ali, Ibtisam A., Grobusch, Martin P., Aradaib, Imadeldin E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5020552/
https://www.ncbi.nlm.nih.gov/pubmed/27619674
http://dx.doi.org/10.1186/s12917-016-0809-2
_version_ 1782453226081091584
author Ahmed, Mohamed E.
Eldigail, Mawahib H.
Elamin, Fatima M.
Ali, Ibtisam A.
Grobusch, Martin P.
Aradaib, Imadeldin E.
author_facet Ahmed, Mohamed E.
Eldigail, Mawahib H.
Elamin, Fatima M.
Ali, Ibtisam A.
Grobusch, Martin P.
Aradaib, Imadeldin E.
author_sort Ahmed, Mohamed E.
collection PubMed
description BACKGROUND: Cystic echinococcosis (CE) or hydatidosis, caused by the larval stage of Echinococcus granulosus (EG)-complex, is a neglected parasitic disease of public health importance. The disease is endemic in many African and Mediterranean countries including the Sudan. The objective of the present study was to develop and evaluate a real-time loop-mediated isothermal amplification (LAMP) assay for simple and rapid detection of CE in humans and domestic live stock in Sudan. METHODS: A set of six LAMP primers, designed from the mitochondrial NADH-1 gene of EG cattle strain of genotype 5 (G5), was used as a target for LAMP assay. The assay was performed at a constant temperature (63 °C), with a real-time follow-up using a LightCycler and fluorochrome dye. Following amplification cycles in a simple water bath, LAMP products were observed for color change by naked eye and were visualized under UV light source using agarose gel electrophoresis. RESULTS: The real-time LAMP assay identified a variety of hydatid cysts strains recovered in the Sudan, including Echinococcus canadenses (G6) and Echinococcus ortleppi (G5). Real-time LAMP positive results were detected by the presence of an amplification curve, whereas negative results were indicated by absence of fluorescence detection. Positive LAMP results appeared as a bluish-colored reaction as observed by naked eye, whereas negative LAMP results were observed as purple-colored reaction. The sensitivity studies indicated that the LAMP assay detected as little as a 10 fg of parasite DNA. There was 100 % agreement between results of the LAMP assay and our previously described nested PCR when testing 10-fold serial dilution of DNA extracted from EG-complex hydatid cyst. However, there was no cross-reactivity with other parasites including cysticercus bovis, Fasciola gigantica, and Schistosoma bovis and nucleic acid free samples. CONCLUSION: The developed LAMP assay would be expected to prove highly significant in epidemiological surveys of CE in developing countries or areas of resource-poor settings for both ease of use and cost.
format Online
Article
Text
id pubmed-5020552
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-50205522016-09-14 Development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis Ahmed, Mohamed E. Eldigail, Mawahib H. Elamin, Fatima M. Ali, Ibtisam A. Grobusch, Martin P. Aradaib, Imadeldin E. BMC Vet Res Methodology Article BACKGROUND: Cystic echinococcosis (CE) or hydatidosis, caused by the larval stage of Echinococcus granulosus (EG)-complex, is a neglected parasitic disease of public health importance. The disease is endemic in many African and Mediterranean countries including the Sudan. The objective of the present study was to develop and evaluate a real-time loop-mediated isothermal amplification (LAMP) assay for simple and rapid detection of CE in humans and domestic live stock in Sudan. METHODS: A set of six LAMP primers, designed from the mitochondrial NADH-1 gene of EG cattle strain of genotype 5 (G5), was used as a target for LAMP assay. The assay was performed at a constant temperature (63 °C), with a real-time follow-up using a LightCycler and fluorochrome dye. Following amplification cycles in a simple water bath, LAMP products were observed for color change by naked eye and were visualized under UV light source using agarose gel electrophoresis. RESULTS: The real-time LAMP assay identified a variety of hydatid cysts strains recovered in the Sudan, including Echinococcus canadenses (G6) and Echinococcus ortleppi (G5). Real-time LAMP positive results were detected by the presence of an amplification curve, whereas negative results were indicated by absence of fluorescence detection. Positive LAMP results appeared as a bluish-colored reaction as observed by naked eye, whereas negative LAMP results were observed as purple-colored reaction. The sensitivity studies indicated that the LAMP assay detected as little as a 10 fg of parasite DNA. There was 100 % agreement between results of the LAMP assay and our previously described nested PCR when testing 10-fold serial dilution of DNA extracted from EG-complex hydatid cyst. However, there was no cross-reactivity with other parasites including cysticercus bovis, Fasciola gigantica, and Schistosoma bovis and nucleic acid free samples. CONCLUSION: The developed LAMP assay would be expected to prove highly significant in epidemiological surveys of CE in developing countries or areas of resource-poor settings for both ease of use and cost. BioMed Central 2016-09-13 /pmc/articles/PMC5020552/ /pubmed/27619674 http://dx.doi.org/10.1186/s12917-016-0809-2 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Methodology Article
Ahmed, Mohamed E.
Eldigail, Mawahib H.
Elamin, Fatima M.
Ali, Ibtisam A.
Grobusch, Martin P.
Aradaib, Imadeldin E.
Development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis
title Development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis
title_full Development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis
title_fullStr Development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis
title_full_unstemmed Development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis
title_short Development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis
title_sort development and evaluation of real-time loop-mediated isothermal amplification assay for rapid detection of cystic echinococcosis
topic Methodology Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5020552/
https://www.ncbi.nlm.nih.gov/pubmed/27619674
http://dx.doi.org/10.1186/s12917-016-0809-2
work_keys_str_mv AT ahmedmohamede developmentandevaluationofrealtimeloopmediatedisothermalamplificationassayforrapiddetectionofcysticechinococcosis
AT eldigailmawahibh developmentandevaluationofrealtimeloopmediatedisothermalamplificationassayforrapiddetectionofcysticechinococcosis
AT elaminfatimam developmentandevaluationofrealtimeloopmediatedisothermalamplificationassayforrapiddetectionofcysticechinococcosis
AT aliibtisama developmentandevaluationofrealtimeloopmediatedisothermalamplificationassayforrapiddetectionofcysticechinococcosis
AT grobuschmartinp developmentandevaluationofrealtimeloopmediatedisothermalamplificationassayforrapiddetectionofcysticechinococcosis
AT aradaibimadeldine developmentandevaluationofrealtimeloopmediatedisothermalamplificationassayforrapiddetectionofcysticechinococcosis