Small punch tensile/fracture test data and 3D specimen surface data on Grade 91 ferritic/martensitic steel from cryogenic to room temperature

Raw data from small punch tensile/fracture tests at two displacement rates in the temperature range from −196 °C to room temperature on Grade 91 ferritic/martensitic steel are presented. A number of specimens were analyzed after testing by means of X-ray computed tomography (CT). Based on the CT vol...

Descripción completa

Detalles Bibliográficos
Autores principales: Bruchhausen, Matthias, Lapetite, Jean-Marc, Ripplinger, Stefan, Austin, Tim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5021917/
https://www.ncbi.nlm.nih.gov/pubmed/27660812
http://dx.doi.org/10.1016/j.dib.2016.08.061
Descripción
Sumario:Raw data from small punch tensile/fracture tests at two displacement rates in the temperature range from −196 °C to room temperature on Grade 91 ferritic/martensitic steel are presented. A number of specimens were analyzed after testing by means of X-ray computed tomography (CT). Based on the CT volume data detailed 3D surface maps of the specimens were established. All data are open access and available from Online Data Information Network (ODIN)https://odin.jrc.ec.europa.eu. The data presented in the current work has been analyzed in the research article “On the determination of the ductile to brittle transition temperature from small punch tests on Grade 91 ferritic-martensitic steel” (M. Bruchhausen, S. Holmström, J.-M. Lapetite, S. Ripplinger, 2015) [1].