Cargando…

Echocardiographic Follow-up of Robotic Mitral Valve Repair for Mitral Regurgitation due to Degenerative Disease

BACKGROUND: Mitral valve (MV) repair can now be carried out through small incisions with the use of robotic assistance. Previous reports have demonstrated the excellent clinical result of robotic MV repair for degenerative mitral regurgitation (MR). However, there has been limited information regard...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yao, Gao, Chang-Qing, Shen, Yan-Song, Wang, Gang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5022341/
https://www.ncbi.nlm.nih.gov/pubmed/27625092
http://dx.doi.org/10.4103/0366-6999.189909
Descripción
Sumario:BACKGROUND: Mitral valve (MV) repair can now be carried out through small incisions with the use of robotic assistance. Previous reports have demonstrated the excellent clinical result of robotic MV repair for degenerative mitral regurgitation (MR). However, there has been limited information regarding the echocardiographic follow-up of these patients. The present study was therefore to evaluate the echocardiographic follow-up outcomes after robotic MV repair in patients with MR due to degenerative disease of the MV. METHODS: A retrospective analysis was undertaken using data from the echocardiographic database of our department. Between March 2007 and February 2015, 84 patients with degenerative MR underwent robotic MV repair. The repair techniques included leaflet resection in 67 patients (79.8%), artificial chordae in 20 (23.8%), and ring annuloplasty in 79 (94.1%). Eighty-one (96.4%) of the 84 patients were eligible for echocardiographic follow-up assessment, and no patients were lost to follow-up. RESULTS: At a median echocardiographic follow-up of 36.0 months (interquartile range 14.3–59.4 months), four patients (4.9%) developed recurrent mild MR, and no patients had more than mild MR. Mean MR grade, left atrial diameter (LAD), left ventricular end-diastolic diameter (LVEDD), and left ventricular ejection fraction (LVEF) were significantly decreased when compared with preoperative values. Mean MR grade decreased from 3.96 ± 0.13 to 0.17 ± 0.49 (Z = −8.456, P < 0.001), LAD from 43.8 ± 5.9 to 35.5 ± 3.8 mm (t = 15.131, P < 0.001), LVEDD from 51.0 ± 5.0 to 43.3 ± 2.2 mm (t = 14.481, P < 0.001), and LVEF from 67.3 ± 7.0% to 63.9 ± 5.1% (t = 4.585, P < 0.001). CONCLUSION: Robotic MV repair for MR due to degenerative disease is associated with a low rate of recurrent MR, and a significant improvement in MR grade, LAD, and LVEDD, but a significant decrease in LVEF at echocardiographic follow-up.