Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor
Nexfin beat-to-beat arterial blood pressure monitoring enables continuous assessment of hemodynamic indices like cardiac index (CI), pulse pressure variation (PPV) and stroke volume variation (SVV) in the perioperative setting. In this study we investigated whether Nexfin adequately reflects alterat...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5023739/ https://www.ncbi.nlm.nih.gov/pubmed/26318314 http://dx.doi.org/10.1007/s10877-015-9759-7 |
_version_ | 1782453677142835200 |
---|---|
author | Stens, Jurre Oeben, Jeroen Van Dusseldorp, Ab A. Boer, Christa |
author_facet | Stens, Jurre Oeben, Jeroen Van Dusseldorp, Ab A. Boer, Christa |
author_sort | Stens, Jurre |
collection | PubMed |
description | Nexfin beat-to-beat arterial blood pressure monitoring enables continuous assessment of hemodynamic indices like cardiac index (CI), pulse pressure variation (PPV) and stroke volume variation (SVV) in the perioperative setting. In this study we investigated whether Nexfin adequately reflects alterations in these hemodynamic parameters during a provoked fluid shift in anesthetized and mechanically ventilated patients. The study included 54 patients undergoing non-thoracic surgery with positive pressure mechanical ventilation. The provoked fluid shift comprised 15° Trendelenburg positioning, and fluid responsiveness was defined as a concomitant increase in stroke volume (SV) >10 %. Nexfin blood pressure measurements were performed during supine steady state, Trendelenburg and supine repositioning. Hemodynamic parameters included arterial blood pressure (MAP), CI, PPV and SVV. Trendelenburg positioning did not affect MAP or CI, but induced a decrease in PPV and SVV by 3.3 ± 2.8 and 3.4 ± 2.7 %, respectively. PPV and SVV returned back to baseline values after repositioning of the patient to baseline. Bland–Altman analysis of SVV and PPV showed a bias of −0.3 ± 3.0 % with limits of agreement ranging from −5.6 to 6.2 %. The SVV was more superior in predicting fluid responsiveness (AUC 0.728) than the PVV (AUC 0.636), respectively. The median bias between PPV and SVV was different for patients younger [−1.5 % (−3 to 0)] or older [+2 % (0–4.75)] than 55 years (P < 0.001), while there were no gender differences in the bias between PPV and SVV. The Nexfin monitor adequately reflects alterations in PPV and SVV during a provoked fluid shift, but the level of agreement between PPV and SVV was low. The SVV tended to be superior over PPV or Ea(dyn) in predicting fluid responsiveness in our population. |
format | Online Article Text |
id | pubmed-5023739 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-50237392016-09-27 Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor Stens, Jurre Oeben, Jeroen Van Dusseldorp, Ab A. Boer, Christa J Clin Monit Comput Original Research Nexfin beat-to-beat arterial blood pressure monitoring enables continuous assessment of hemodynamic indices like cardiac index (CI), pulse pressure variation (PPV) and stroke volume variation (SVV) in the perioperative setting. In this study we investigated whether Nexfin adequately reflects alterations in these hemodynamic parameters during a provoked fluid shift in anesthetized and mechanically ventilated patients. The study included 54 patients undergoing non-thoracic surgery with positive pressure mechanical ventilation. The provoked fluid shift comprised 15° Trendelenburg positioning, and fluid responsiveness was defined as a concomitant increase in stroke volume (SV) >10 %. Nexfin blood pressure measurements were performed during supine steady state, Trendelenburg and supine repositioning. Hemodynamic parameters included arterial blood pressure (MAP), CI, PPV and SVV. Trendelenburg positioning did not affect MAP or CI, but induced a decrease in PPV and SVV by 3.3 ± 2.8 and 3.4 ± 2.7 %, respectively. PPV and SVV returned back to baseline values after repositioning of the patient to baseline. Bland–Altman analysis of SVV and PPV showed a bias of −0.3 ± 3.0 % with limits of agreement ranging from −5.6 to 6.2 %. The SVV was more superior in predicting fluid responsiveness (AUC 0.728) than the PVV (AUC 0.636), respectively. The median bias between PPV and SVV was different for patients younger [−1.5 % (−3 to 0)] or older [+2 % (0–4.75)] than 55 years (P < 0.001), while there were no gender differences in the bias between PPV and SVV. The Nexfin monitor adequately reflects alterations in PPV and SVV during a provoked fluid shift, but the level of agreement between PPV and SVV was low. The SVV tended to be superior over PPV or Ea(dyn) in predicting fluid responsiveness in our population. Springer Netherlands 2015-08-29 2016 /pmc/articles/PMC5023739/ /pubmed/26318314 http://dx.doi.org/10.1007/s10877-015-9759-7 Text en © The Author(s) 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Research Stens, Jurre Oeben, Jeroen Van Dusseldorp, Ab A. Boer, Christa Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor |
title | Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor |
title_full | Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor |
title_fullStr | Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor |
title_full_unstemmed | Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor |
title_short | Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor |
title_sort | non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the nexfin blood pressure monitor |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5023739/ https://www.ncbi.nlm.nih.gov/pubmed/26318314 http://dx.doi.org/10.1007/s10877-015-9759-7 |
work_keys_str_mv | AT stensjurre noninvasivemeasurementsofpulsepressurevariationandstrokevolumevariationinanesthetizedpatientsusingthenexfinbloodpressuremonitor AT oebenjeroen noninvasivemeasurementsofpulsepressurevariationandstrokevolumevariationinanesthetizedpatientsusingthenexfinbloodpressuremonitor AT vandusseldorpaba noninvasivemeasurementsofpulsepressurevariationandstrokevolumevariationinanesthetizedpatientsusingthenexfinbloodpressuremonitor AT boerchrista noninvasivemeasurementsofpulsepressurevariationandstrokevolumevariationinanesthetizedpatientsusingthenexfinbloodpressuremonitor |