Cargando…

Improved method for measurement of multi-walled carbon nanotubes in rat lung

BACKGROUND: Previously, we have developed and reported the method of measuring multi-walled carbon nanotube (MWCNT) in the lung from rats exposed to MWCNT intratracheally. The present research was performed to improve the analytical method of MWCNT to measure multiple samples in a short period of ti...

Descripción completa

Detalles Bibliográficos
Autores principales: Ohnishi, Makoto, Suzuki, Masaaki, Yamamoto, Masahiro, Kasai, Tatsuya, Kano, Hirokazu, Senoh, Hideki, Higashikubo, Ichiro, Araki, Akihiro, Fukushima, Shoji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5024449/
https://www.ncbi.nlm.nih.gov/pubmed/27651824
http://dx.doi.org/10.1186/s12995-016-0132-7
_version_ 1782453801804890112
author Ohnishi, Makoto
Suzuki, Masaaki
Yamamoto, Masahiro
Kasai, Tatsuya
Kano, Hirokazu
Senoh, Hideki
Higashikubo, Ichiro
Araki, Akihiro
Fukushima, Shoji
author_facet Ohnishi, Makoto
Suzuki, Masaaki
Yamamoto, Masahiro
Kasai, Tatsuya
Kano, Hirokazu
Senoh, Hideki
Higashikubo, Ichiro
Araki, Akihiro
Fukushima, Shoji
author_sort Ohnishi, Makoto
collection PubMed
description BACKGROUND: Previously, we have developed and reported the method of measuring multi-walled carbon nanotube (MWCNT) in the lung from rats exposed to MWCNT intratracheally. The present research was performed to improve the analytical method of MWCNT to measure multiple samples in a short period of time. For the xanalysis of MWCNTs from tissues, the existence of carbon black may interfere. Therefore, it was examined whether or not carbon black interfere the determination of MWCNT in the standard solutions. Then, MWCNTs were administered to rats and the MWCNTs were determined in the rats by the new method and the recovery rates and time for determination were calculated. The standard solutions for MWCNTs and carbon black were prepared, and the concentrations in the solutions were determined by HPLC with checking their linearity between the concentrations and signal intensities. The reproducibility of the determination was also checked. METHODS: The concentrations of MWCMTs in the standard solutions were determined by HPLC with a fluorescent detector. Those of carbon black were also determined using the same method. The MWCNTs were administered to rats intratracheally. The MWCNTs in the lung were determined in a newly modified method including digestion of lung tissues by strong alkali solution and marking MWCNTs by benzo[ghi]perylene. The time for the determinations was recorded and the recovery rate of MWVNTs was calculated. RESULTS: MWCNT showed linearity in a range of 0.2 to 1.0 μg/mL. In contrast, carbon black demonstrated a very low slope, showing flat pattern. Regarding the reproducibility of the analysis, the coefficient of variation was lower than 10 %. The analysis of 20 samples were completed in 1.5 h. The recovery rates of MWCNT from the lung of rats receiving intratracheal MWCNT administration were 101 to 102 %. CONCLUSIONS: The improved method for measuring MWCNT allows an efficient MWCNT quantitation in a short period of time. Also, a small amount of MWCNTs can be measured without influence of carbon black.
format Online
Article
Text
id pubmed-5024449
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-50244492016-09-20 Improved method for measurement of multi-walled carbon nanotubes in rat lung Ohnishi, Makoto Suzuki, Masaaki Yamamoto, Masahiro Kasai, Tatsuya Kano, Hirokazu Senoh, Hideki Higashikubo, Ichiro Araki, Akihiro Fukushima, Shoji J Occup Med Toxicol Short Report BACKGROUND: Previously, we have developed and reported the method of measuring multi-walled carbon nanotube (MWCNT) in the lung from rats exposed to MWCNT intratracheally. The present research was performed to improve the analytical method of MWCNT to measure multiple samples in a short period of time. For the xanalysis of MWCNTs from tissues, the existence of carbon black may interfere. Therefore, it was examined whether or not carbon black interfere the determination of MWCNT in the standard solutions. Then, MWCNTs were administered to rats and the MWCNTs were determined in the rats by the new method and the recovery rates and time for determination were calculated. The standard solutions for MWCNTs and carbon black were prepared, and the concentrations in the solutions were determined by HPLC with checking their linearity between the concentrations and signal intensities. The reproducibility of the determination was also checked. METHODS: The concentrations of MWCMTs in the standard solutions were determined by HPLC with a fluorescent detector. Those of carbon black were also determined using the same method. The MWCNTs were administered to rats intratracheally. The MWCNTs in the lung were determined in a newly modified method including digestion of lung tissues by strong alkali solution and marking MWCNTs by benzo[ghi]perylene. The time for the determinations was recorded and the recovery rate of MWVNTs was calculated. RESULTS: MWCNT showed linearity in a range of 0.2 to 1.0 μg/mL. In contrast, carbon black demonstrated a very low slope, showing flat pattern. Regarding the reproducibility of the analysis, the coefficient of variation was lower than 10 %. The analysis of 20 samples were completed in 1.5 h. The recovery rates of MWCNT from the lung of rats receiving intratracheal MWCNT administration were 101 to 102 %. CONCLUSIONS: The improved method for measuring MWCNT allows an efficient MWCNT quantitation in a short period of time. Also, a small amount of MWCNTs can be measured without influence of carbon black. BioMed Central 2016-09-15 /pmc/articles/PMC5024449/ /pubmed/27651824 http://dx.doi.org/10.1186/s12995-016-0132-7 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Short Report
Ohnishi, Makoto
Suzuki, Masaaki
Yamamoto, Masahiro
Kasai, Tatsuya
Kano, Hirokazu
Senoh, Hideki
Higashikubo, Ichiro
Araki, Akihiro
Fukushima, Shoji
Improved method for measurement of multi-walled carbon nanotubes in rat lung
title Improved method for measurement of multi-walled carbon nanotubes in rat lung
title_full Improved method for measurement of multi-walled carbon nanotubes in rat lung
title_fullStr Improved method for measurement of multi-walled carbon nanotubes in rat lung
title_full_unstemmed Improved method for measurement of multi-walled carbon nanotubes in rat lung
title_short Improved method for measurement of multi-walled carbon nanotubes in rat lung
title_sort improved method for measurement of multi-walled carbon nanotubes in rat lung
topic Short Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5024449/
https://www.ncbi.nlm.nih.gov/pubmed/27651824
http://dx.doi.org/10.1186/s12995-016-0132-7
work_keys_str_mv AT ohnishimakoto improvedmethodformeasurementofmultiwalledcarbonnanotubesinratlung
AT suzukimasaaki improvedmethodformeasurementofmultiwalledcarbonnanotubesinratlung
AT yamamotomasahiro improvedmethodformeasurementofmultiwalledcarbonnanotubesinratlung
AT kasaitatsuya improvedmethodformeasurementofmultiwalledcarbonnanotubesinratlung
AT kanohirokazu improvedmethodformeasurementofmultiwalledcarbonnanotubesinratlung
AT senohhideki improvedmethodformeasurementofmultiwalledcarbonnanotubesinratlung
AT higashikuboichiro improvedmethodformeasurementofmultiwalledcarbonnanotubesinratlung
AT arakiakihiro improvedmethodformeasurementofmultiwalledcarbonnanotubesinratlung
AT fukushimashoji improvedmethodformeasurementofmultiwalledcarbonnanotubesinratlung