Cargando…

‘Pre-endoscopy point of care test (Simtomax- IgA/IgG-Deamidated Gliadin Peptide) for coeliac disease in iron deficiency anaemia: diagnostic accuracy and a cost saving economic model’

BACKGROUND: International guidelines recommend coeliac serology in iron deficiency anaemia, and duodenal biopsy for those tested positive to detect coeliac disease. However, pre-endoscopy serology is often unavailable, thus committing endoscopists to take routine duodenal biopsies. Some endoscopists...

Descripción completa

Detalles Bibliográficos
Autores principales: Lau, Michelle Shui Yee, Mooney, Peter, White, William, Appleby, Victoria, Moreea, Sulleman, Haythem, Ismail, Elias, Joshua, Bundhoo, Kiran, Corbett, Gareth, Wong, Liam, Tsai, Her Hsin, Cross, Simon, Hebden, John, Hoque, Sami, Sanders, David
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5024457/
https://www.ncbi.nlm.nih.gov/pubmed/27628523
http://dx.doi.org/10.1186/s12876-016-0521-5
_version_ 1782453803668209664
author Lau, Michelle Shui Yee
Mooney, Peter
White, William
Appleby, Victoria
Moreea, Sulleman
Haythem, Ismail
Elias, Joshua
Bundhoo, Kiran
Corbett, Gareth
Wong, Liam
Tsai, Her Hsin
Cross, Simon
Hebden, John
Hoque, Sami
Sanders, David
author_facet Lau, Michelle Shui Yee
Mooney, Peter
White, William
Appleby, Victoria
Moreea, Sulleman
Haythem, Ismail
Elias, Joshua
Bundhoo, Kiran
Corbett, Gareth
Wong, Liam
Tsai, Her Hsin
Cross, Simon
Hebden, John
Hoque, Sami
Sanders, David
author_sort Lau, Michelle Shui Yee
collection PubMed
description BACKGROUND: International guidelines recommend coeliac serology in iron deficiency anaemia, and duodenal biopsy for those tested positive to detect coeliac disease. However, pre-endoscopy serology is often unavailable, thus committing endoscopists to take routine duodenal biopsies. Some endoscopists consider duodenal biopsy mandatory in anaemia to exclude other pathologies. We hypothesise that using a point of care test at endoscopy could fill this gap, by providing rapid results to target anaemic patients who require biopsies, and save costs by biopsy avoidance. We therefore assessed three key aspects to this hypothesis: 1) the availability of pre-endoscopy serology in anaemia; 2) the sensitivities and cost effectiveness of pre-endoscopy coeliac screening with Simtomax in anaemia; 3) whether other anaemia-related pathologies could be missed by this targeted-biopsy approach. METHODS: Group 1: pre-endoscopy serology availability was retrospectively analysed in a multicentre cohort of 934 anaemic patients at 4 UK hospitals. Group 2: the sensitivities of Simtomax, endomysial and tissue-transglutaminase antibodies were compared in 133 prospectively recruited patients with iron deficiency anaemia attending for a gastroscopy. The sensitivities were measured against duodenal histology as the reference standard in all patients. The cost effectiveness of Simtomax was calculated based on the number of biopsies that could have been avoided compared to an all-biopsy approach. Group 3: the duodenal histology of 153 patients presenting to a separate iron deficiency anaemia clinic were retrospectively reviewed. RESULTS: In group 1, serology was available in 361 (33.8 %) patients. In group 2, the sensitivity and negative predictive value (NPV) were 100 % and 100 % for Simtomax, 96.2 % and 98.9 % for IgA-TTG, and 84.6 % and 96.4 % for EMA respectively. In group 3, the duodenal histology found no causes for anaemia other than coeliac disease. CONCLUSION: Simtomax had excellent diagnostic accuracy in iron deficiency anaemia and was comparable to conventional serology. Duodenal biopsy did not identify any causes other than coeliac disease for iron deficiency anaemia, suggesting that biopsy avoidance in Simtomax negative anaemic patients is unlikely to miss other anaemia-related pathologies. Due to its 100 % NPV, Simtomax could reduce unnecessary biopsies by 66 % if only those with a positive Simtomax were biopsied, potentially saving £3690/100 gastroscopies. TRIAL REGISTRATION: The group 2 study was retrospectively registered with clinicaltrials.gov. Trial registration date: 13(th) July 2016; Trial registration number: NCT02834429.
format Online
Article
Text
id pubmed-5024457
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-50244572016-09-20 ‘Pre-endoscopy point of care test (Simtomax- IgA/IgG-Deamidated Gliadin Peptide) for coeliac disease in iron deficiency anaemia: diagnostic accuracy and a cost saving economic model’ Lau, Michelle Shui Yee Mooney, Peter White, William Appleby, Victoria Moreea, Sulleman Haythem, Ismail Elias, Joshua Bundhoo, Kiran Corbett, Gareth Wong, Liam Tsai, Her Hsin Cross, Simon Hebden, John Hoque, Sami Sanders, David BMC Gastroenterol Research Article BACKGROUND: International guidelines recommend coeliac serology in iron deficiency anaemia, and duodenal biopsy for those tested positive to detect coeliac disease. However, pre-endoscopy serology is often unavailable, thus committing endoscopists to take routine duodenal biopsies. Some endoscopists consider duodenal biopsy mandatory in anaemia to exclude other pathologies. We hypothesise that using a point of care test at endoscopy could fill this gap, by providing rapid results to target anaemic patients who require biopsies, and save costs by biopsy avoidance. We therefore assessed three key aspects to this hypothesis: 1) the availability of pre-endoscopy serology in anaemia; 2) the sensitivities and cost effectiveness of pre-endoscopy coeliac screening with Simtomax in anaemia; 3) whether other anaemia-related pathologies could be missed by this targeted-biopsy approach. METHODS: Group 1: pre-endoscopy serology availability was retrospectively analysed in a multicentre cohort of 934 anaemic patients at 4 UK hospitals. Group 2: the sensitivities of Simtomax, endomysial and tissue-transglutaminase antibodies were compared in 133 prospectively recruited patients with iron deficiency anaemia attending for a gastroscopy. The sensitivities were measured against duodenal histology as the reference standard in all patients. The cost effectiveness of Simtomax was calculated based on the number of biopsies that could have been avoided compared to an all-biopsy approach. Group 3: the duodenal histology of 153 patients presenting to a separate iron deficiency anaemia clinic were retrospectively reviewed. RESULTS: In group 1, serology was available in 361 (33.8 %) patients. In group 2, the sensitivity and negative predictive value (NPV) were 100 % and 100 % for Simtomax, 96.2 % and 98.9 % for IgA-TTG, and 84.6 % and 96.4 % for EMA respectively. In group 3, the duodenal histology found no causes for anaemia other than coeliac disease. CONCLUSION: Simtomax had excellent diagnostic accuracy in iron deficiency anaemia and was comparable to conventional serology. Duodenal biopsy did not identify any causes other than coeliac disease for iron deficiency anaemia, suggesting that biopsy avoidance in Simtomax negative anaemic patients is unlikely to miss other anaemia-related pathologies. Due to its 100 % NPV, Simtomax could reduce unnecessary biopsies by 66 % if only those with a positive Simtomax were biopsied, potentially saving £3690/100 gastroscopies. TRIAL REGISTRATION: The group 2 study was retrospectively registered with clinicaltrials.gov. Trial registration date: 13(th) July 2016; Trial registration number: NCT02834429. BioMed Central 2016-09-15 /pmc/articles/PMC5024457/ /pubmed/27628523 http://dx.doi.org/10.1186/s12876-016-0521-5 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Lau, Michelle Shui Yee
Mooney, Peter
White, William
Appleby, Victoria
Moreea, Sulleman
Haythem, Ismail
Elias, Joshua
Bundhoo, Kiran
Corbett, Gareth
Wong, Liam
Tsai, Her Hsin
Cross, Simon
Hebden, John
Hoque, Sami
Sanders, David
‘Pre-endoscopy point of care test (Simtomax- IgA/IgG-Deamidated Gliadin Peptide) for coeliac disease in iron deficiency anaemia: diagnostic accuracy and a cost saving economic model’
title ‘Pre-endoscopy point of care test (Simtomax- IgA/IgG-Deamidated Gliadin Peptide) for coeliac disease in iron deficiency anaemia: diagnostic accuracy and a cost saving economic model’
title_full ‘Pre-endoscopy point of care test (Simtomax- IgA/IgG-Deamidated Gliadin Peptide) for coeliac disease in iron deficiency anaemia: diagnostic accuracy and a cost saving economic model’
title_fullStr ‘Pre-endoscopy point of care test (Simtomax- IgA/IgG-Deamidated Gliadin Peptide) for coeliac disease in iron deficiency anaemia: diagnostic accuracy and a cost saving economic model’
title_full_unstemmed ‘Pre-endoscopy point of care test (Simtomax- IgA/IgG-Deamidated Gliadin Peptide) for coeliac disease in iron deficiency anaemia: diagnostic accuracy and a cost saving economic model’
title_short ‘Pre-endoscopy point of care test (Simtomax- IgA/IgG-Deamidated Gliadin Peptide) for coeliac disease in iron deficiency anaemia: diagnostic accuracy and a cost saving economic model’
title_sort ‘pre-endoscopy point of care test (simtomax- iga/igg-deamidated gliadin peptide) for coeliac disease in iron deficiency anaemia: diagnostic accuracy and a cost saving economic model’
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5024457/
https://www.ncbi.nlm.nih.gov/pubmed/27628523
http://dx.doi.org/10.1186/s12876-016-0521-5
work_keys_str_mv AT laumichelleshuiyee preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT mooneypeter preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT whitewilliam preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT applebyvictoria preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT moreeasulleman preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT haythemismail preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT eliasjoshua preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT bundhookiran preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT corbettgareth preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT wongliam preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT tsaiherhsin preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT crosssimon preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT hebdenjohn preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT hoquesami preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel
AT sandersdavid preendoscopypointofcaretestsimtomaxigaiggdeamidatedgliadinpeptideforcoeliacdiseaseinirondeficiencyanaemiadiagnosticaccuracyandacostsavingeconomicmodel