Halo and spillover effect illustrations for selected beneficial medical devices and drugs

BACKGROUND: Negative news media reports regarding potential health hazards of implanted medical devices and pharmaceuticals can lead to a ‘negative halo effect,’ a phenomenon whereby judgments about a product or product type can be unconsciously altered even though the scientific support is tenuous....

Descripción completa

Detalles Bibliográficos
Autores principales: Kerger, Brent D., Bernal, Autumn, Paustenbach, Dennis J., Huntley-Fenner, Gavin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5024505/
https://www.ncbi.nlm.nih.gov/pubmed/27630095
http://dx.doi.org/10.1186/s12889-016-3595-7
_version_ 1782453814786260992
author Kerger, Brent D.
Bernal, Autumn
Paustenbach, Dennis J.
Huntley-Fenner, Gavin
author_facet Kerger, Brent D.
Bernal, Autumn
Paustenbach, Dennis J.
Huntley-Fenner, Gavin
author_sort Kerger, Brent D.
collection PubMed
description BACKGROUND: Negative news media reports regarding potential health hazards of implanted medical devices and pharmaceuticals can lead to a ‘negative halo effect,’ a phenomenon whereby judgments about a product or product type can be unconsciously altered even though the scientific support is tenuous. To determine how a ‘negative halo effect’ may impact the rates of use and/or explantation of medical products, we analyzed the occurrence of such an effect on three implanted medical devices and one drug: 1) intrauterine contraceptive devices (IUDs); 2) silicone gel-filled breast implants (SGBI); 3) metal-on-metal hip implants (MoM); and 4) the drug Tysabri. METHODS: Data on IUD use from 1965 to 2008 were gathered from the Department of Health and Human Services Vital and Health Statistics and peer-reviewed publications. Data regarding SGBI implant and explantation rates from 1989 to 2012 were obtained from the Institute of Medicine and the American Society of Plastic Surgeons. MoM implant and explantation data were extracted from the England and Wales National Joint Registry and peer-reviewed publications. Tysabri patient data were reported by Elan Corporation or Biogen Idec Inc. Data trends for all products were compared with historical recall or withdrawal events and discussed in the context of public perceptions following such events. RESULTS: We found that common factors altered public risk perceptions and patterns of continued use. First, a negative halo effect may be driven by continuing patient anxiety despite positive clinical outcomes. Second, negative reports about one product can spill over to affect the use of dissimilar products in the same category. Third, a negative halo effect on an entire category of medical devices can be sustained regardless of the scientific findings pertaining to safety. Fourth, recovery of a product’s safety reputation and prevalent use may take decades in the U.S., even while these products may exhibit widespread use and good safety records in other countries. CONCLUSIONS: We conclude that the ‘negative halo effect’ associated with a stigma, rather than an objective risk-benefit assessment of medical products can increase negative health outcomes for patients due to reduced or inappropriate product usage.
format Online
Article
Text
id pubmed-5024505
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-50245052016-09-20 Halo and spillover effect illustrations for selected beneficial medical devices and drugs Kerger, Brent D. Bernal, Autumn Paustenbach, Dennis J. Huntley-Fenner, Gavin BMC Public Health Research Article BACKGROUND: Negative news media reports regarding potential health hazards of implanted medical devices and pharmaceuticals can lead to a ‘negative halo effect,’ a phenomenon whereby judgments about a product or product type can be unconsciously altered even though the scientific support is tenuous. To determine how a ‘negative halo effect’ may impact the rates of use and/or explantation of medical products, we analyzed the occurrence of such an effect on three implanted medical devices and one drug: 1) intrauterine contraceptive devices (IUDs); 2) silicone gel-filled breast implants (SGBI); 3) metal-on-metal hip implants (MoM); and 4) the drug Tysabri. METHODS: Data on IUD use from 1965 to 2008 were gathered from the Department of Health and Human Services Vital and Health Statistics and peer-reviewed publications. Data regarding SGBI implant and explantation rates from 1989 to 2012 were obtained from the Institute of Medicine and the American Society of Plastic Surgeons. MoM implant and explantation data were extracted from the England and Wales National Joint Registry and peer-reviewed publications. Tysabri patient data were reported by Elan Corporation or Biogen Idec Inc. Data trends for all products were compared with historical recall or withdrawal events and discussed in the context of public perceptions following such events. RESULTS: We found that common factors altered public risk perceptions and patterns of continued use. First, a negative halo effect may be driven by continuing patient anxiety despite positive clinical outcomes. Second, negative reports about one product can spill over to affect the use of dissimilar products in the same category. Third, a negative halo effect on an entire category of medical devices can be sustained regardless of the scientific findings pertaining to safety. Fourth, recovery of a product’s safety reputation and prevalent use may take decades in the U.S., even while these products may exhibit widespread use and good safety records in other countries. CONCLUSIONS: We conclude that the ‘negative halo effect’ associated with a stigma, rather than an objective risk-benefit assessment of medical products can increase negative health outcomes for patients due to reduced or inappropriate product usage. BioMed Central 2016-09-15 /pmc/articles/PMC5024505/ /pubmed/27630095 http://dx.doi.org/10.1186/s12889-016-3595-7 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Kerger, Brent D.
Bernal, Autumn
Paustenbach, Dennis J.
Huntley-Fenner, Gavin
Halo and spillover effect illustrations for selected beneficial medical devices and drugs
title Halo and spillover effect illustrations for selected beneficial medical devices and drugs
title_full Halo and spillover effect illustrations for selected beneficial medical devices and drugs
title_fullStr Halo and spillover effect illustrations for selected beneficial medical devices and drugs
title_full_unstemmed Halo and spillover effect illustrations for selected beneficial medical devices and drugs
title_short Halo and spillover effect illustrations for selected beneficial medical devices and drugs
title_sort halo and spillover effect illustrations for selected beneficial medical devices and drugs
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5024505/
https://www.ncbi.nlm.nih.gov/pubmed/27630095
http://dx.doi.org/10.1186/s12889-016-3595-7
work_keys_str_mv AT kergerbrentd haloandspillovereffectillustrationsforselectedbeneficialmedicaldevicesanddrugs
AT bernalautumn haloandspillovereffectillustrationsforselectedbeneficialmedicaldevicesanddrugs
AT paustenbachdennisj haloandspillovereffectillustrationsforselectedbeneficialmedicaldevicesanddrugs
AT huntleyfennergavin haloandspillovereffectillustrationsforselectedbeneficialmedicaldevicesanddrugs