Cargando…
Macular SD-OCT Outcome Measures: Comparison of Local Structure-Function Relationships and Dynamic Range
PURPOSE: We tested the hypothesis that the macular ganglion cell layer (GCL) thickness demonstrates a stronger structure-function (SF) relationship and extends the useful range of macular measurements compared with combined macular inner layer or full thickness. METHODS: Ninety-eight glaucomatous ey...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5024670/ https://www.ncbi.nlm.nih.gov/pubmed/27623336 http://dx.doi.org/10.1167/iovs.16-19648 |
_version_ | 1782453827530653696 |
---|---|
author | Miraftabi, Arezoo Amini, Navid Morales, Esteban Henry, Sharon Yu, Fei Afifi, Abdolmonem Coleman, Anne L. Caprioli, Joseph Nouri-Mahdavi, Kouros |
author_facet | Miraftabi, Arezoo Amini, Navid Morales, Esteban Henry, Sharon Yu, Fei Afifi, Abdolmonem Coleman, Anne L. Caprioli, Joseph Nouri-Mahdavi, Kouros |
author_sort | Miraftabi, Arezoo |
collection | PubMed |
description | PURPOSE: We tested the hypothesis that the macular ganglion cell layer (GCL) thickness demonstrates a stronger structure-function (SF) relationship and extends the useful range of macular measurements compared with combined macular inner layer or full thickness. METHODS: Ninety-eight glaucomatous eyes and eight normal eyes with macular spectral domain optical coherence tomography (SD-OCT) volume scans and 10-2 visual fields were enrolled. Inner plexiform layer (IPL), GCL, macular retinal nerve fiber layer (mRNFL), ganglion cell-inner plexiform layer (GCIPL), ganglion cell complex (GCC), and full thickness (FT) measurements were calculated for 8 × 8 arrays of 3° superpixels. Main outcome measures were local structure-function relationships between macular superpixels and corresponding sensitivities on 10-2 fields after adjusting for ganglion cell displacement, dynamic range of measurements, and the change point (total deviation value where macular parameters reached measurement floor). RESULTS: Median (interquartile range [IQR]) mean deviation was −7.2 (−11.6 to −3.2) dB in glaucoma eyes. Strength of SF relationships was highest for GCIPL, GCL, GCC, and IPL (ρ = 0.635, 0.627, 0.621, and 0.577, respectively; P ≤ 0.046 for comparisons against GCIPL). Highest SF correlations coincided with the peak of GCL thickness, where the dynamic range was widest for FT (81.1 μm), followed by GCC (65.7 μm), GCIPL (54.9 μm), GCL (35.2 μm), mRNFL (27.5 μm), and IPL (20.9 μm). Change points were similar for all macular parameters (−7.8 to −8.9 dB). CONCLUSIONS: GCIPL, GCL, and GCC demonstrated comparable SF relationships while FT, GCC, and GCIPL had the widest dynamic range. Measurement of GCL did not extend the range of useful structural measurements. Measuring GCL does not provide any advantage for detection of progression with current SD-OCT technology. |
format | Online Article Text |
id | pubmed-5024670 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-50246702016-09-16 Macular SD-OCT Outcome Measures: Comparison of Local Structure-Function Relationships and Dynamic Range Miraftabi, Arezoo Amini, Navid Morales, Esteban Henry, Sharon Yu, Fei Afifi, Abdolmonem Coleman, Anne L. Caprioli, Joseph Nouri-Mahdavi, Kouros Invest Ophthalmol Vis Sci Glaucoma PURPOSE: We tested the hypothesis that the macular ganglion cell layer (GCL) thickness demonstrates a stronger structure-function (SF) relationship and extends the useful range of macular measurements compared with combined macular inner layer or full thickness. METHODS: Ninety-eight glaucomatous eyes and eight normal eyes with macular spectral domain optical coherence tomography (SD-OCT) volume scans and 10-2 visual fields were enrolled. Inner plexiform layer (IPL), GCL, macular retinal nerve fiber layer (mRNFL), ganglion cell-inner plexiform layer (GCIPL), ganglion cell complex (GCC), and full thickness (FT) measurements were calculated for 8 × 8 arrays of 3° superpixels. Main outcome measures were local structure-function relationships between macular superpixels and corresponding sensitivities on 10-2 fields after adjusting for ganglion cell displacement, dynamic range of measurements, and the change point (total deviation value where macular parameters reached measurement floor). RESULTS: Median (interquartile range [IQR]) mean deviation was −7.2 (−11.6 to −3.2) dB in glaucoma eyes. Strength of SF relationships was highest for GCIPL, GCL, GCC, and IPL (ρ = 0.635, 0.627, 0.621, and 0.577, respectively; P ≤ 0.046 for comparisons against GCIPL). Highest SF correlations coincided with the peak of GCL thickness, where the dynamic range was widest for FT (81.1 μm), followed by GCC (65.7 μm), GCIPL (54.9 μm), GCL (35.2 μm), mRNFL (27.5 μm), and IPL (20.9 μm). Change points were similar for all macular parameters (−7.8 to −8.9 dB). CONCLUSIONS: GCIPL, GCL, and GCC demonstrated comparable SF relationships while FT, GCC, and GCIPL had the widest dynamic range. Measurement of GCL did not extend the range of useful structural measurements. Measuring GCL does not provide any advantage for detection of progression with current SD-OCT technology. The Association for Research in Vision and Ophthalmology 2016-09-13 2016-09 /pmc/articles/PMC5024670/ /pubmed/27623336 http://dx.doi.org/10.1167/iovs.16-19648 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Glaucoma Miraftabi, Arezoo Amini, Navid Morales, Esteban Henry, Sharon Yu, Fei Afifi, Abdolmonem Coleman, Anne L. Caprioli, Joseph Nouri-Mahdavi, Kouros Macular SD-OCT Outcome Measures: Comparison of Local Structure-Function Relationships and Dynamic Range |
title | Macular SD-OCT Outcome Measures: Comparison of Local Structure-Function Relationships and Dynamic Range |
title_full | Macular SD-OCT Outcome Measures: Comparison of Local Structure-Function Relationships and Dynamic Range |
title_fullStr | Macular SD-OCT Outcome Measures: Comparison of Local Structure-Function Relationships and Dynamic Range |
title_full_unstemmed | Macular SD-OCT Outcome Measures: Comparison of Local Structure-Function Relationships and Dynamic Range |
title_short | Macular SD-OCT Outcome Measures: Comparison of Local Structure-Function Relationships and Dynamic Range |
title_sort | macular sd-oct outcome measures: comparison of local structure-function relationships and dynamic range |
topic | Glaucoma |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5024670/ https://www.ncbi.nlm.nih.gov/pubmed/27623336 http://dx.doi.org/10.1167/iovs.16-19648 |
work_keys_str_mv | AT miraftabiarezoo macularsdoctoutcomemeasurescomparisonoflocalstructurefunctionrelationshipsanddynamicrange AT amininavid macularsdoctoutcomemeasurescomparisonoflocalstructurefunctionrelationshipsanddynamicrange AT moralesesteban macularsdoctoutcomemeasurescomparisonoflocalstructurefunctionrelationshipsanddynamicrange AT henrysharon macularsdoctoutcomemeasurescomparisonoflocalstructurefunctionrelationshipsanddynamicrange AT yufei macularsdoctoutcomemeasurescomparisonoflocalstructurefunctionrelationshipsanddynamicrange AT afifiabdolmonem macularsdoctoutcomemeasurescomparisonoflocalstructurefunctionrelationshipsanddynamicrange AT colemanannel macularsdoctoutcomemeasurescomparisonoflocalstructurefunctionrelationshipsanddynamicrange AT capriolijoseph macularsdoctoutcomemeasurescomparisonoflocalstructurefunctionrelationshipsanddynamicrange AT nourimahdavikouros macularsdoctoutcomemeasurescomparisonoflocalstructurefunctionrelationshipsanddynamicrange |