Cargando…

Ultrasound measurements of the liver: an intra and inter‐rater reliability study

Introduction: Ultrasound is an easy and inexpensive method to rapidly assess the size of the adult liver. The literature addressing reliability of liver measurements using ultrasound is poorly reported and inadequate. In this study, intra and inter‐rater reliability of multiple measurements of the r...

Descripción completa

Detalles Bibliográficos
Autores principales: Childs, Jessie T, Esterman, Adrian J, Thoirs, Kerry A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5024948/
https://www.ncbi.nlm.nih.gov/pubmed/28191220
http://dx.doi.org/10.1002/j.2205-0140.2014.tb00026.x
_version_ 1782453868762759168
author Childs, Jessie T
Esterman, Adrian J
Thoirs, Kerry A
author_facet Childs, Jessie T
Esterman, Adrian J
Thoirs, Kerry A
author_sort Childs, Jessie T
collection PubMed
description Introduction: Ultrasound is an easy and inexpensive method to rapidly assess the size of the adult liver. The literature addressing reliability of liver measurements using ultrasound is poorly reported and inadequate. In this study, intra and inter‐rater reliability of multiple measurements of the right lobe, left lobe and entire adult liver were assessed. Methods: Two examiners acquired ultrasound images of the liver in multiple positions. Fifteen measurements were taken from each set of images by each examiner. One examiner repeated the images and measurements. Results: Results demonstrated high intra‐rater reliability for all measurements (ICC's 0.67–0.97). Inter‐rater reliability also demonstrated high reliability (ICC's 0.71–0.94) for nine of the fifteen measurements (six representing the right lobe, one representing the left lobe and two representing the entire liver. Further analysis using paired samples t‐tests and Bland Altman plots were performed on these nine measurements. Conclusion: From this study, the most reliable measurements are suggested to be MCL Dome to tip and MCL Max AP for the right lobe and Midline Max AP for the left lobe. The only measurement to truly encompass both lobes (Max Trans) was not shown to be reliable.
format Online
Article
Text
id pubmed-5024948
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-50249482017-02-10 Ultrasound measurements of the liver: an intra and inter‐rater reliability study Childs, Jessie T Esterman, Adrian J Thoirs, Kerry A Australas J Ultrasound Med Original Research Introduction: Ultrasound is an easy and inexpensive method to rapidly assess the size of the adult liver. The literature addressing reliability of liver measurements using ultrasound is poorly reported and inadequate. In this study, intra and inter‐rater reliability of multiple measurements of the right lobe, left lobe and entire adult liver were assessed. Methods: Two examiners acquired ultrasound images of the liver in multiple positions. Fifteen measurements were taken from each set of images by each examiner. One examiner repeated the images and measurements. Results: Results demonstrated high intra‐rater reliability for all measurements (ICC's 0.67–0.97). Inter‐rater reliability also demonstrated high reliability (ICC's 0.71–0.94) for nine of the fifteen measurements (six representing the right lobe, one representing the left lobe and two representing the entire liver. Further analysis using paired samples t‐tests and Bland Altman plots were performed on these nine measurements. Conclusion: From this study, the most reliable measurements are suggested to be MCL Dome to tip and MCL Max AP for the right lobe and Midline Max AP for the left lobe. The only measurement to truly encompass both lobes (Max Trans) was not shown to be reliable. John Wiley and Sons Inc. 2015-12-31 2014-08 /pmc/articles/PMC5024948/ /pubmed/28191220 http://dx.doi.org/10.1002/j.2205-0140.2014.tb00026.x Text en © 2014 Australasian Society for Ultrasound in Medicine
spellingShingle Original Research
Childs, Jessie T
Esterman, Adrian J
Thoirs, Kerry A
Ultrasound measurements of the liver: an intra and inter‐rater reliability study
title Ultrasound measurements of the liver: an intra and inter‐rater reliability study
title_full Ultrasound measurements of the liver: an intra and inter‐rater reliability study
title_fullStr Ultrasound measurements of the liver: an intra and inter‐rater reliability study
title_full_unstemmed Ultrasound measurements of the liver: an intra and inter‐rater reliability study
title_short Ultrasound measurements of the liver: an intra and inter‐rater reliability study
title_sort ultrasound measurements of the liver: an intra and inter‐rater reliability study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5024948/
https://www.ncbi.nlm.nih.gov/pubmed/28191220
http://dx.doi.org/10.1002/j.2205-0140.2014.tb00026.x
work_keys_str_mv AT childsjessiet ultrasoundmeasurementsoftheliveranintraandinterraterreliabilitystudy
AT estermanadrianj ultrasoundmeasurementsoftheliveranintraandinterraterreliabilitystudy
AT thoirskerrya ultrasoundmeasurementsoftheliveranintraandinterraterreliabilitystudy