Control of Pedicle Screw Placement with an Electrical Conductivity Measurement Device: Initial Evaluation in the Thoracic and Lumbar Spine

Aim. Transpedicular screw fixation is widely used in spinal surgery. But the insertion of pedicle screws can sometimes be challenging because of the variability in pedicle size and the proximity of nerve roots. Methods. We detected intraoperatively the sensitivity for iatrogenic pedicel perforation...

Descripción completa

Detalles Bibliográficos
Autores principales: Suess, Olaf, Schomacher, Markus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5028864/
https://www.ncbi.nlm.nih.gov/pubmed/27699203
http://dx.doi.org/10.1155/2016/4296294
_version_ 1782454414809759744
author Suess, Olaf
Schomacher, Markus
author_facet Suess, Olaf
Schomacher, Markus
author_sort Suess, Olaf
collection PubMed
description Aim. Transpedicular screw fixation is widely used in spinal surgery. But the insertion of pedicle screws can sometimes be challenging because of the variability in pedicle size and the proximity of nerve roots. Methods. We detected intraoperatively the sensitivity for iatrogenic pedicel perforation with a hand-held electronic conductivity measurement device (ECD) that measures electrical conductivity of tissue-medium surrounding the instrument tip. ECD was used to guide the placement of 84 pedicle screws in 15 patients undergoing surgery for tumor or degenerative spinal disease at various spinal levels from T8 to L5. Additionally a CT-scan controlled screw positioning postoperatively. Results. The placement was “correct” (no mediocaudal pedicle wall penetration) for 78 of 84 (92,8%) screws, “suboptimal but acceptable” (0–2 mm penetration) for 4 of 84 (4,8%) screws, and “misplaced” (penetration > 2 mm) for 2 of 84 (2,4%) screws. Conclusion. Although this study was not designed to compare electronic conductivity technique to other guidance methods, such as fluoroscopy or navigation, a convincing “proof of concept” for ECD use in spinal instrumentation could be demonstrated. Advantages include easy handling without time-consuming setup and reduced X-ray exposure. However, further investigations are necessary to evaluate i.a. the economic aspects for this single-use developed instrument.
format Online
Article
Text
id pubmed-5028864
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-50288642016-10-03 Control of Pedicle Screw Placement with an Electrical Conductivity Measurement Device: Initial Evaluation in the Thoracic and Lumbar Spine Suess, Olaf Schomacher, Markus Adv Med Research Article Aim. Transpedicular screw fixation is widely used in spinal surgery. But the insertion of pedicle screws can sometimes be challenging because of the variability in pedicle size and the proximity of nerve roots. Methods. We detected intraoperatively the sensitivity for iatrogenic pedicel perforation with a hand-held electronic conductivity measurement device (ECD) that measures electrical conductivity of tissue-medium surrounding the instrument tip. ECD was used to guide the placement of 84 pedicle screws in 15 patients undergoing surgery for tumor or degenerative spinal disease at various spinal levels from T8 to L5. Additionally a CT-scan controlled screw positioning postoperatively. Results. The placement was “correct” (no mediocaudal pedicle wall penetration) for 78 of 84 (92,8%) screws, “suboptimal but acceptable” (0–2 mm penetration) for 4 of 84 (4,8%) screws, and “misplaced” (penetration > 2 mm) for 2 of 84 (2,4%) screws. Conclusion. Although this study was not designed to compare electronic conductivity technique to other guidance methods, such as fluoroscopy or navigation, a convincing “proof of concept” for ECD use in spinal instrumentation could be demonstrated. Advantages include easy handling without time-consuming setup and reduced X-ray exposure. However, further investigations are necessary to evaluate i.a. the economic aspects for this single-use developed instrument. Hindawi Publishing Corporation 2016 2016-09-06 /pmc/articles/PMC5028864/ /pubmed/27699203 http://dx.doi.org/10.1155/2016/4296294 Text en Copyright © 2016 O. Suess and M. Schomacher. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Suess, Olaf
Schomacher, Markus
Control of Pedicle Screw Placement with an Electrical Conductivity Measurement Device: Initial Evaluation in the Thoracic and Lumbar Spine
title Control of Pedicle Screw Placement with an Electrical Conductivity Measurement Device: Initial Evaluation in the Thoracic and Lumbar Spine
title_full Control of Pedicle Screw Placement with an Electrical Conductivity Measurement Device: Initial Evaluation in the Thoracic and Lumbar Spine
title_fullStr Control of Pedicle Screw Placement with an Electrical Conductivity Measurement Device: Initial Evaluation in the Thoracic and Lumbar Spine
title_full_unstemmed Control of Pedicle Screw Placement with an Electrical Conductivity Measurement Device: Initial Evaluation in the Thoracic and Lumbar Spine
title_short Control of Pedicle Screw Placement with an Electrical Conductivity Measurement Device: Initial Evaluation in the Thoracic and Lumbar Spine
title_sort control of pedicle screw placement with an electrical conductivity measurement device: initial evaluation in the thoracic and lumbar spine
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5028864/
https://www.ncbi.nlm.nih.gov/pubmed/27699203
http://dx.doi.org/10.1155/2016/4296294
work_keys_str_mv AT suessolaf controlofpediclescrewplacementwithanelectricalconductivitymeasurementdeviceinitialevaluationinthethoracicandlumbarspine
AT schomachermarkus controlofpediclescrewplacementwithanelectricalconductivitymeasurementdeviceinitialevaluationinthethoracicandlumbarspine