Cargando…

Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints

BACKGROUND: Deformable image registration (DIR) is a key component in many radiotherapy applications. However, often resulting deformations are not satisfying, since varying deformation properties of different anatomical regions are not considered. To improve the plausibility of DIR in adaptive radi...

Descripción completa

Detalles Bibliográficos
Autores principales: König, Lars, Derksen, Alexander, Papenberg, Nils, Haas, Benjamin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5029058/
https://www.ncbi.nlm.nih.gov/pubmed/27647456
http://dx.doi.org/10.1186/s13014-016-0697-4
_version_ 1782454455302619136
author König, Lars
Derksen, Alexander
Papenberg, Nils
Haas, Benjamin
author_facet König, Lars
Derksen, Alexander
Papenberg, Nils
Haas, Benjamin
author_sort König, Lars
collection PubMed
description BACKGROUND: Deformable image registration (DIR) is a key component in many radiotherapy applications. However, often resulting deformations are not satisfying, since varying deformation properties of different anatomical regions are not considered. To improve the plausibility of DIR in adaptive radiotherapy in the male pelvic area, this work integrates a local rigidity deformation model into a DIR algorithm. METHODS: A DIR framework is extended by constraints, enforcing locally rigid deformation behavior for arbitrary delineated structures. The approach restricts those structures to rigid deformations, while surrounding tissue is still allowed to deform elastically. The algorithm is tested on ten CT/CBCT male pelvis datasets with active rigidity constraints on bones and prostate and compared to the Varian SmartAdapt deformable registration (VSA) on delineations of bladder, prostate and bones. RESULTS: The approach with no rigid structures (REG0) obtains an average dice similarity coefficient (DSC) of 0.87 ± 0.06 and a Hausdorff-Distance (HD) of 8.74 ± 5.95 mm. The new approach with rigid bones (REG1) yields a DSC of 0.87 ± 0.07, HD 8.91 ± 5.89 mm. Rigid deformation of bones and prostate (REG2) obtains 0.87 ± 0.06, HD 8.73 ± 6.01 mm, while VSA yields a DSC of 0.86 ± 0.07, HD 10.22 ± 6.62 mm. No deformation grid foldings are observed for REG0 and REG1 in 7 of 10 cases; for REG2 in 8 of 10 cases, with no grid foldings in prostate, an average of 0.08 % in bladder (REG2: no foldings) and 0.01 % inside the body contour. VSA exhibits grid foldings in each case, with an average percentage of 1.81 % for prostate, 1.74 % for bladder and 0.12 % for the body contour. While REG1 and REG2 keep bones rigid, elastic bone deformations are observed with REG0 and VSA. An average runtime of 26.2 s was achieved with REG1; 31.1 s with REG2, compared to 10.5 s with REG0 and 10.7 s with VMS. CONCLUSIONS: With accuracy in the range of VSA, the new approach with constraints delivers physically more plausible deformations in the pelvic area with guaranteed rigidity of arbitrary structures. Although the algorithm uses an advanced deformation model, clinically feasible runtimes are achieved. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13014-016-0697-4) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5029058
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-50290582016-09-22 Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints König, Lars Derksen, Alexander Papenberg, Nils Haas, Benjamin Radiat Oncol Research BACKGROUND: Deformable image registration (DIR) is a key component in many radiotherapy applications. However, often resulting deformations are not satisfying, since varying deformation properties of different anatomical regions are not considered. To improve the plausibility of DIR in adaptive radiotherapy in the male pelvic area, this work integrates a local rigidity deformation model into a DIR algorithm. METHODS: A DIR framework is extended by constraints, enforcing locally rigid deformation behavior for arbitrary delineated structures. The approach restricts those structures to rigid deformations, while surrounding tissue is still allowed to deform elastically. The algorithm is tested on ten CT/CBCT male pelvis datasets with active rigidity constraints on bones and prostate and compared to the Varian SmartAdapt deformable registration (VSA) on delineations of bladder, prostate and bones. RESULTS: The approach with no rigid structures (REG0) obtains an average dice similarity coefficient (DSC) of 0.87 ± 0.06 and a Hausdorff-Distance (HD) of 8.74 ± 5.95 mm. The new approach with rigid bones (REG1) yields a DSC of 0.87 ± 0.07, HD 8.91 ± 5.89 mm. Rigid deformation of bones and prostate (REG2) obtains 0.87 ± 0.06, HD 8.73 ± 6.01 mm, while VSA yields a DSC of 0.86 ± 0.07, HD 10.22 ± 6.62 mm. No deformation grid foldings are observed for REG0 and REG1 in 7 of 10 cases; for REG2 in 8 of 10 cases, with no grid foldings in prostate, an average of 0.08 % in bladder (REG2: no foldings) and 0.01 % inside the body contour. VSA exhibits grid foldings in each case, with an average percentage of 1.81 % for prostate, 1.74 % for bladder and 0.12 % for the body contour. While REG1 and REG2 keep bones rigid, elastic bone deformations are observed with REG0 and VSA. An average runtime of 26.2 s was achieved with REG1; 31.1 s with REG2, compared to 10.5 s with REG0 and 10.7 s with VMS. CONCLUSIONS: With accuracy in the range of VSA, the new approach with constraints delivers physically more plausible deformations in the pelvic area with guaranteed rigidity of arbitrary structures. Although the algorithm uses an advanced deformation model, clinically feasible runtimes are achieved. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13014-016-0697-4) contains supplementary material, which is available to authorized users. BioMed Central 2016-09-20 /pmc/articles/PMC5029058/ /pubmed/27647456 http://dx.doi.org/10.1186/s13014-016-0697-4 Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License(http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver(http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
König, Lars
Derksen, Alexander
Papenberg, Nils
Haas, Benjamin
Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
title Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
title_full Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
title_fullStr Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
title_full_unstemmed Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
title_short Deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
title_sort deformable image registration for adaptive radiotherapy with guaranteed local rigidity constraints
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5029058/
https://www.ncbi.nlm.nih.gov/pubmed/27647456
http://dx.doi.org/10.1186/s13014-016-0697-4
work_keys_str_mv AT koniglars deformableimageregistrationforadaptiveradiotherapywithguaranteedlocalrigidityconstraints
AT derksenalexander deformableimageregistrationforadaptiveradiotherapywithguaranteedlocalrigidityconstraints
AT papenbergnils deformableimageregistrationforadaptiveradiotherapywithguaranteedlocalrigidityconstraints
AT haasbenjamin deformableimageregistrationforadaptiveradiotherapywithguaranteedlocalrigidityconstraints