Adverse reaction to metal debris in a painful hemiarthroplasty of the hip

Adverse reaction to metal debris (ARMD) in total hip arthroplasty surgery is a well-known problem. We present the case of a unipolar hemiarthroplasty requiring revision within 18 months of insertion secondary to an adverse reaction to metal debris. This case demonstrates a rare cause for failure of...

Descripción completa

Detalles Bibliográficos
Autores principales: Palmer, Jonathan Simon, Dean, Michael William, Briant-Evans, Toby, Stranks, Geoff
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5031076/
https://www.ncbi.nlm.nih.gov/pubmed/27656196
http://dx.doi.org/10.1093/jscr/rjw160
_version_ 1782454750338351104
author Palmer, Jonathan Simon
Dean, Michael William
Briant-Evans, Toby
Stranks, Geoff
author_facet Palmer, Jonathan Simon
Dean, Michael William
Briant-Evans, Toby
Stranks, Geoff
author_sort Palmer, Jonathan Simon
collection PubMed
description Adverse reaction to metal debris (ARMD) in total hip arthroplasty surgery is a well-known problem. We present the case of a unipolar hemiarthroplasty requiring revision within 18 months of insertion secondary to an adverse reaction to metal debris. This case demonstrates a rare cause for failure of a hemiarthroplasty following a fragility fracture. We feel that ARMD should be considered in all cases where pain and dysfunction in the presence of any hip prosthesis cannot be explained by routine investigations.
format Online
Article
Text
id pubmed-5031076
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-50310762016-09-22 Adverse reaction to metal debris in a painful hemiarthroplasty of the hip Palmer, Jonathan Simon Dean, Michael William Briant-Evans, Toby Stranks, Geoff J Surg Case Rep Case Report Adverse reaction to metal debris (ARMD) in total hip arthroplasty surgery is a well-known problem. We present the case of a unipolar hemiarthroplasty requiring revision within 18 months of insertion secondary to an adverse reaction to metal debris. This case demonstrates a rare cause for failure of a hemiarthroplasty following a fragility fracture. We feel that ARMD should be considered in all cases where pain and dysfunction in the presence of any hip prosthesis cannot be explained by routine investigations. Oxford University Press 2016-09-21 /pmc/articles/PMC5031076/ /pubmed/27656196 http://dx.doi.org/10.1093/jscr/rjw160 Text en Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author 2016. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Report
Palmer, Jonathan Simon
Dean, Michael William
Briant-Evans, Toby
Stranks, Geoff
Adverse reaction to metal debris in a painful hemiarthroplasty of the hip
title Adverse reaction to metal debris in a painful hemiarthroplasty of the hip
title_full Adverse reaction to metal debris in a painful hemiarthroplasty of the hip
title_fullStr Adverse reaction to metal debris in a painful hemiarthroplasty of the hip
title_full_unstemmed Adverse reaction to metal debris in a painful hemiarthroplasty of the hip
title_short Adverse reaction to metal debris in a painful hemiarthroplasty of the hip
title_sort adverse reaction to metal debris in a painful hemiarthroplasty of the hip
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5031076/
https://www.ncbi.nlm.nih.gov/pubmed/27656196
http://dx.doi.org/10.1093/jscr/rjw160
work_keys_str_mv AT palmerjonathansimon adversereactiontometaldebrisinapainfulhemiarthroplastyofthehip
AT deanmichaelwilliam adversereactiontometaldebrisinapainfulhemiarthroplastyofthehip
AT briantevanstoby adversereactiontometaldebrisinapainfulhemiarthroplastyofthehip
AT stranksgeoff adversereactiontometaldebrisinapainfulhemiarthroplastyofthehip