Cargando…
Bronchoesophageal Fistula Stenting Using High-Frequency Jet Ventilation and Underwater Seal Gastrostomy Tube Drainage
Managing a patient scheduled for bronchoesophageal fistula repair is challenging for the anesthetist. If appropriate ventilation strategy is not employed, serious complications such as hypoxemia, gastric distension, and pulmonary aspiration can occur. We present the case of a 62-year-old man with a...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5031825/ https://www.ncbi.nlm.nih.gov/pubmed/27672454 http://dx.doi.org/10.1155/2016/8175127 |
_version_ | 1782454866546786304 |
---|---|
author | Fokeerah, Nitish Liu, Xinwei Hao, Yonggang Peng, Lihua |
author_facet | Fokeerah, Nitish Liu, Xinwei Hao, Yonggang Peng, Lihua |
author_sort | Fokeerah, Nitish |
collection | PubMed |
description | Managing a patient scheduled for bronchoesophageal fistula repair is challenging for the anesthetist. If appropriate ventilation strategy is not employed, serious complications such as hypoxemia, gastric distension, and pulmonary aspiration can occur. We present the case of a 62-year-old man with a bronchoesophageal fistula in the left main stem bronchus requiring the insertion of a Y-shaped tracheobronchial stent through a rigid bronchoscope, under general anesthesia. We successfully managed this intervention and herein report this case to demonstrate the effectiveness of underwater seal gastrostomy tube drainage used in conjunction with high-frequency jet ventilation during bronchoesophageal fistula stenting. |
format | Online Article Text |
id | pubmed-5031825 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-50318252016-09-26 Bronchoesophageal Fistula Stenting Using High-Frequency Jet Ventilation and Underwater Seal Gastrostomy Tube Drainage Fokeerah, Nitish Liu, Xinwei Hao, Yonggang Peng, Lihua Case Rep Anesthesiol Case Report Managing a patient scheduled for bronchoesophageal fistula repair is challenging for the anesthetist. If appropriate ventilation strategy is not employed, serious complications such as hypoxemia, gastric distension, and pulmonary aspiration can occur. We present the case of a 62-year-old man with a bronchoesophageal fistula in the left main stem bronchus requiring the insertion of a Y-shaped tracheobronchial stent through a rigid bronchoscope, under general anesthesia. We successfully managed this intervention and herein report this case to demonstrate the effectiveness of underwater seal gastrostomy tube drainage used in conjunction with high-frequency jet ventilation during bronchoesophageal fistula stenting. Hindawi Publishing Corporation 2016 2016-09-08 /pmc/articles/PMC5031825/ /pubmed/27672454 http://dx.doi.org/10.1155/2016/8175127 Text en Copyright © 2016 Nitish Fokeerah et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Fokeerah, Nitish Liu, Xinwei Hao, Yonggang Peng, Lihua Bronchoesophageal Fistula Stenting Using High-Frequency Jet Ventilation and Underwater Seal Gastrostomy Tube Drainage |
title | Bronchoesophageal Fistula Stenting Using High-Frequency Jet Ventilation and Underwater Seal Gastrostomy Tube Drainage |
title_full | Bronchoesophageal Fistula Stenting Using High-Frequency Jet Ventilation and Underwater Seal Gastrostomy Tube Drainage |
title_fullStr | Bronchoesophageal Fistula Stenting Using High-Frequency Jet Ventilation and Underwater Seal Gastrostomy Tube Drainage |
title_full_unstemmed | Bronchoesophageal Fistula Stenting Using High-Frequency Jet Ventilation and Underwater Seal Gastrostomy Tube Drainage |
title_short | Bronchoesophageal Fistula Stenting Using High-Frequency Jet Ventilation and Underwater Seal Gastrostomy Tube Drainage |
title_sort | bronchoesophageal fistula stenting using high-frequency jet ventilation and underwater seal gastrostomy tube drainage |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5031825/ https://www.ncbi.nlm.nih.gov/pubmed/27672454 http://dx.doi.org/10.1155/2016/8175127 |
work_keys_str_mv | AT fokeerahnitish bronchoesophagealfistulastentingusinghighfrequencyjetventilationandunderwatersealgastrostomytubedrainage AT liuxinwei bronchoesophagealfistulastentingusinghighfrequencyjetventilationandunderwatersealgastrostomytubedrainage AT haoyonggang bronchoesophagealfistulastentingusinghighfrequencyjetventilationandunderwatersealgastrostomytubedrainage AT penglihua bronchoesophagealfistulastentingusinghighfrequencyjetventilationandunderwatersealgastrostomytubedrainage |