Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy

In this case report, we look into the implant procedure of a single-lead ICD with floating atrial sensing dipole in a pregnant woman, without using fluoroscopy. This system benefits the proper positioning of the lead. This is possible thanks to the simultaneous display of both the atrial and ventric...

Descripción completa

Detalles Bibliográficos
Autores principales: Quartieri, Fabio, Giacopelli, Daniele, Iori, Matteo, Bottoni, Nicola
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5031860/
https://www.ncbi.nlm.nih.gov/pubmed/27676164
http://dx.doi.org/10.1016/j.ipej.2016.08.004
_version_ 1782454874507575296
author Quartieri, Fabio
Giacopelli, Daniele
Iori, Matteo
Bottoni, Nicola
author_facet Quartieri, Fabio
Giacopelli, Daniele
Iori, Matteo
Bottoni, Nicola
author_sort Quartieri, Fabio
collection PubMed
description In this case report, we look into the implant procedure of a single-lead ICD with floating atrial sensing dipole in a pregnant woman, without using fluoroscopy. This system benefits the proper positioning of the lead. This is possible thanks to the simultaneous display of both the atrial and ventricular dipoles on the electro-anatomical mapping system. This technique may be taken into consideration for the few rare cases where fluoroscopy is absolutely contraindicated.
format Online
Article
Text
id pubmed-5031860
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-50318602016-09-29 Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy Quartieri, Fabio Giacopelli, Daniele Iori, Matteo Bottoni, Nicola Indian Pacing Electrophysiol J Case Report In this case report, we look into the implant procedure of a single-lead ICD with floating atrial sensing dipole in a pregnant woman, without using fluoroscopy. This system benefits the proper positioning of the lead. This is possible thanks to the simultaneous display of both the atrial and ventricular dipoles on the electro-anatomical mapping system. This technique may be taken into consideration for the few rare cases where fluoroscopy is absolutely contraindicated. Elsevier 2016-08-20 /pmc/articles/PMC5031860/ /pubmed/27676164 http://dx.doi.org/10.1016/j.ipej.2016.08.004 Text en Copyright © 2016, Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Quartieri, Fabio
Giacopelli, Daniele
Iori, Matteo
Bottoni, Nicola
Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
title Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
title_full Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
title_fullStr Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
title_full_unstemmed Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
title_short Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
title_sort implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5031860/
https://www.ncbi.nlm.nih.gov/pubmed/27676164
http://dx.doi.org/10.1016/j.ipej.2016.08.004
work_keys_str_mv AT quartierifabio implantationofsingleleadcardioverterdefibrillatorwithfloatingatrialsensingdipoleinapregnantpatientwithoutusingfluoroscopy
AT giacopellidaniele implantationofsingleleadcardioverterdefibrillatorwithfloatingatrialsensingdipoleinapregnantpatientwithoutusingfluoroscopy
AT iorimatteo implantationofsingleleadcardioverterdefibrillatorwithfloatingatrialsensingdipoleinapregnantpatientwithoutusingfluoroscopy
AT bottoninicola implantationofsingleleadcardioverterdefibrillatorwithfloatingatrialsensingdipoleinapregnantpatientwithoutusingfluoroscopy