Cargando…
Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy
In this case report, we look into the implant procedure of a single-lead ICD with floating atrial sensing dipole in a pregnant woman, without using fluoroscopy. This system benefits the proper positioning of the lead. This is possible thanks to the simultaneous display of both the atrial and ventric...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5031860/ https://www.ncbi.nlm.nih.gov/pubmed/27676164 http://dx.doi.org/10.1016/j.ipej.2016.08.004 |
_version_ | 1782454874507575296 |
---|---|
author | Quartieri, Fabio Giacopelli, Daniele Iori, Matteo Bottoni, Nicola |
author_facet | Quartieri, Fabio Giacopelli, Daniele Iori, Matteo Bottoni, Nicola |
author_sort | Quartieri, Fabio |
collection | PubMed |
description | In this case report, we look into the implant procedure of a single-lead ICD with floating atrial sensing dipole in a pregnant woman, without using fluoroscopy. This system benefits the proper positioning of the lead. This is possible thanks to the simultaneous display of both the atrial and ventricular dipoles on the electro-anatomical mapping system. This technique may be taken into consideration for the few rare cases where fluoroscopy is absolutely contraindicated. |
format | Online Article Text |
id | pubmed-5031860 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-50318602016-09-29 Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy Quartieri, Fabio Giacopelli, Daniele Iori, Matteo Bottoni, Nicola Indian Pacing Electrophysiol J Case Report In this case report, we look into the implant procedure of a single-lead ICD with floating atrial sensing dipole in a pregnant woman, without using fluoroscopy. This system benefits the proper positioning of the lead. This is possible thanks to the simultaneous display of both the atrial and ventricular dipoles on the electro-anatomical mapping system. This technique may be taken into consideration for the few rare cases where fluoroscopy is absolutely contraindicated. Elsevier 2016-08-20 /pmc/articles/PMC5031860/ /pubmed/27676164 http://dx.doi.org/10.1016/j.ipej.2016.08.004 Text en Copyright © 2016, Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Quartieri, Fabio Giacopelli, Daniele Iori, Matteo Bottoni, Nicola Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy |
title | Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy |
title_full | Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy |
title_fullStr | Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy |
title_full_unstemmed | Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy |
title_short | Implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy |
title_sort | implantation of single lead cardioverter defibrillator with floating atrial sensing dipole in a pregnant patient without using fluoroscopy |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5031860/ https://www.ncbi.nlm.nih.gov/pubmed/27676164 http://dx.doi.org/10.1016/j.ipej.2016.08.004 |
work_keys_str_mv | AT quartierifabio implantationofsingleleadcardioverterdefibrillatorwithfloatingatrialsensingdipoleinapregnantpatientwithoutusingfluoroscopy AT giacopellidaniele implantationofsingleleadcardioverterdefibrillatorwithfloatingatrialsensingdipoleinapregnantpatientwithoutusingfluoroscopy AT iorimatteo implantationofsingleleadcardioverterdefibrillatorwithfloatingatrialsensingdipoleinapregnantpatientwithoutusingfluoroscopy AT bottoninicola implantationofsingleleadcardioverterdefibrillatorwithfloatingatrialsensingdipoleinapregnantpatientwithoutusingfluoroscopy |