Cargando…

Intravascular Ultrasound for Intracranial and Extracranial Carotid Artery Stent Placement

Intravascular ultrasound (IVUS) can provide valuable information regarding endoluminal morphology. We present the first description of IVUS-guided intracranial and extracranial carotid artery stent placement for arterial dissection. A 41-year-old female with a sudden-onset headache and blurred visio...

Descripción completa

Detalles Bibliográficos
Autores principales: Hussain, Ahmad S, Hussain, Namath S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5031923/
https://www.ncbi.nlm.nih.gov/pubmed/27672529
http://dx.doi.org/10.7759/cureus.732
_version_ 1782454887952416768
author Hussain, Ahmad S
Hussain, Namath S
author_facet Hussain, Ahmad S
Hussain, Namath S
author_sort Hussain, Ahmad S
collection PubMed
description Intravascular ultrasound (IVUS) can provide valuable information regarding endoluminal morphology. We present the first description of IVUS-guided intracranial and extracranial carotid artery stent placement for arterial dissection. A 41-year-old female with a sudden-onset headache and blurred vision underwent a computed tomography (CT) angiogram imaging that revealed bilateral carotid artery dissections (BCAD) and a left vertebral artery dissection (VAD). Endovascular treatment (EVT) of a long segment right carotid artery dissection (CAD) was performed employing two Carotid WALLSTENT™ Monorails™ (8 x 36 mm, 10 x 31 mm) (Boston Scientific, Marlborough, MA). With the help of the IVUS, the distal stent was placed up to the petrous carotid artery, followed by the placement of the second stent in the immediate proximal location with some overlap that extended down to the carotid artery bulb. Intraoperative angiography and post-stenting IVUS revealed excellent stent placement with good resolution of the dissection and good luminal patency with pseudolumen obliteration. Stent use for intracranial circulation dissections will continue to be a favorable option given the decreased morbidity of endovascular therapy in this location. As endovascular surgeons become more facile with the use of IVUS, using it as a guide for stent placement and post-stenting confirmation will help them to ensure proper positioning and improved patency rates.
format Online
Article
Text
id pubmed-5031923
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-50319232016-09-26 Intravascular Ultrasound for Intracranial and Extracranial Carotid Artery Stent Placement Hussain, Ahmad S Hussain, Namath S Cureus General Surgery Intravascular ultrasound (IVUS) can provide valuable information regarding endoluminal morphology. We present the first description of IVUS-guided intracranial and extracranial carotid artery stent placement for arterial dissection. A 41-year-old female with a sudden-onset headache and blurred vision underwent a computed tomography (CT) angiogram imaging that revealed bilateral carotid artery dissections (BCAD) and a left vertebral artery dissection (VAD). Endovascular treatment (EVT) of a long segment right carotid artery dissection (CAD) was performed employing two Carotid WALLSTENT™ Monorails™ (8 x 36 mm, 10 x 31 mm) (Boston Scientific, Marlborough, MA). With the help of the IVUS, the distal stent was placed up to the petrous carotid artery, followed by the placement of the second stent in the immediate proximal location with some overlap that extended down to the carotid artery bulb. Intraoperative angiography and post-stenting IVUS revealed excellent stent placement with good resolution of the dissection and good luminal patency with pseudolumen obliteration. Stent use for intracranial circulation dissections will continue to be a favorable option given the decreased morbidity of endovascular therapy in this location. As endovascular surgeons become more facile with the use of IVUS, using it as a guide for stent placement and post-stenting confirmation will help them to ensure proper positioning and improved patency rates. Cureus 2016-08-10 /pmc/articles/PMC5031923/ /pubmed/27672529 http://dx.doi.org/10.7759/cureus.732 Text en Copyright © 2016, Hussain et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle General Surgery
Hussain, Ahmad S
Hussain, Namath S
Intravascular Ultrasound for Intracranial and Extracranial Carotid Artery Stent Placement
title Intravascular Ultrasound for Intracranial and Extracranial Carotid Artery Stent Placement
title_full Intravascular Ultrasound for Intracranial and Extracranial Carotid Artery Stent Placement
title_fullStr Intravascular Ultrasound for Intracranial and Extracranial Carotid Artery Stent Placement
title_full_unstemmed Intravascular Ultrasound for Intracranial and Extracranial Carotid Artery Stent Placement
title_short Intravascular Ultrasound for Intracranial and Extracranial Carotid Artery Stent Placement
title_sort intravascular ultrasound for intracranial and extracranial carotid artery stent placement
topic General Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5031923/
https://www.ncbi.nlm.nih.gov/pubmed/27672529
http://dx.doi.org/10.7759/cureus.732
work_keys_str_mv AT hussainahmads intravascularultrasoundforintracranialandextracranialcarotidarterystentplacement
AT hussainnamaths intravascularultrasoundforintracranialandextracranialcarotidarterystentplacement