Delayed Type IIIb endoleak secondary to graft fabric tear 7 years following implantation of a Medtronic Talent endovascular aortic device: A case report and review of the literature
OBJECTIVES: To report a rare case of delayed Type IIIb endoleak secondary to fabric tear following implantation of a Medtronic Talent endovascular device. METHODS: A 83-year old gentleman underwent elective endovascular aneurysm repair for infrarenal abdominal aortic aneurysm with a Medtronic bifurc...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5033069/ https://www.ncbi.nlm.nih.gov/pubmed/27708782 http://dx.doi.org/10.1177/2050313X16670304 |
Sumario: | OBJECTIVES: To report a rare case of delayed Type IIIb endoleak secondary to fabric tear following implantation of a Medtronic Talent endovascular device. METHODS: A 83-year old gentleman underwent elective endovascular aneurysm repair for infrarenal abdominal aortic aneurysm with a Medtronic bifurcated stent graft in 2008. RESULTS: Seven years after the initial repair, imaging surveillance revealed significant endoleak and brisk aneurysm sac expansion due to Type IIIb endoleak secondary to endograft limb fabric tear. CONCLUSIONS: This case illustrates the imperative role of imaging surveillance in detection of long-term endovascular aneurysm repair complications. Furthermore, we discuss exclusion of the graft tear with aortouniiliac stent grafting as the treatment for this complication. |
---|