Cargando…

Rapid On-Site Evaluation Does Not Improve Endoscopic Ultrasound-Guided Fine Needle Aspiration Adequacy in Pancreatic Masses: A Meta-Analysis and Systematic Review

BACKGROUND AND OBJECTIVES: Rapid on-site evaluation (ROSE) during endoscopic ultrasonography-guided fine needle aspiration (EUS–FNA) of pancreatic masses has been reported to be associated with improved adequacy and diagnostic yield. However, recent observational data on the impact of ROSE have repo...

Descripción completa

Detalles Bibliográficos
Autores principales: Kong, Fanyang, Zhu, Jianwei, Kong, Xiangyu, Sun, Tao, Deng, Xuan, Du, Yiqi, Li, Zhaoshen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5033338/
https://www.ncbi.nlm.nih.gov/pubmed/27657529
http://dx.doi.org/10.1371/journal.pone.0163056
_version_ 1782455123022184448
author Kong, Fanyang
Zhu, Jianwei
Kong, Xiangyu
Sun, Tao
Deng, Xuan
Du, Yiqi
Li, Zhaoshen
author_facet Kong, Fanyang
Zhu, Jianwei
Kong, Xiangyu
Sun, Tao
Deng, Xuan
Du, Yiqi
Li, Zhaoshen
author_sort Kong, Fanyang
collection PubMed
description BACKGROUND AND OBJECTIVES: Rapid on-site evaluation (ROSE) during endoscopic ultrasonography-guided fine needle aspiration (EUS–FNA) of pancreatic masses has been reported to be associated with improved adequacy and diagnostic yield. However, recent observational data on the impact of ROSE have reported conflicting results. A meta-analysis and systematic review was therefore conducted to evaluate the contribution of ROSE during EUS-FNA of pancreatic masses. METHOD: A systematic search was conducted in MEDLINE/Pubmed and EMBASE databases for studies comparing the efficacy of ROSE between patients in two cohorts. Outcomes considered included diagnostic adequate rate, diagnostic yield, number of needle passes, pooled sensitivity and specificity. Findings from a random-effects model were expressed as pooled risk difference (RD) with 95% confidence intervals (CIs). RESULTS: A total of 7 studies (1299 patients) was finally included and further analyzed in the current meta-analysis. EUS-FNA with ROSE could not improve diagnostic adequacy (RD = 0.05, 95% CI: -0.01–0.11) and diagnostic yield (RD = 0.04 95%CI: -0.05, 0.13). The number of needle passes showed no statistically significant difference with and without ROSE (RD = -0.68 95%CI: -2.35, 0.98). The pooled sensitivity and specificity of ROSE group were 0.91 (95%CI: 0.87, 0.94) and 1 (95%CI: 0.94, 1.00). The pooled sensitivity and specificity of non-ROSE group were 0.85 (95%CI: 0.80, 0.89) and 1 (95%CI: 0.95, 1.00). ROSE group and non-ROSE group showed comparable sensitivity and specificity. CONCLUSION: Compared to historical reports of its clinical efficacy in patients with pancreatic lesions, ROSE may be not associated with an improvement of diagnostic yield, adequate rate, pooled sensitivity and specificity.
format Online
Article
Text
id pubmed-5033338
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-50333382016-10-10 Rapid On-Site Evaluation Does Not Improve Endoscopic Ultrasound-Guided Fine Needle Aspiration Adequacy in Pancreatic Masses: A Meta-Analysis and Systematic Review Kong, Fanyang Zhu, Jianwei Kong, Xiangyu Sun, Tao Deng, Xuan Du, Yiqi Li, Zhaoshen PLoS One Research Article BACKGROUND AND OBJECTIVES: Rapid on-site evaluation (ROSE) during endoscopic ultrasonography-guided fine needle aspiration (EUS–FNA) of pancreatic masses has been reported to be associated with improved adequacy and diagnostic yield. However, recent observational data on the impact of ROSE have reported conflicting results. A meta-analysis and systematic review was therefore conducted to evaluate the contribution of ROSE during EUS-FNA of pancreatic masses. METHOD: A systematic search was conducted in MEDLINE/Pubmed and EMBASE databases for studies comparing the efficacy of ROSE between patients in two cohorts. Outcomes considered included diagnostic adequate rate, diagnostic yield, number of needle passes, pooled sensitivity and specificity. Findings from a random-effects model were expressed as pooled risk difference (RD) with 95% confidence intervals (CIs). RESULTS: A total of 7 studies (1299 patients) was finally included and further analyzed in the current meta-analysis. EUS-FNA with ROSE could not improve diagnostic adequacy (RD = 0.05, 95% CI: -0.01–0.11) and diagnostic yield (RD = 0.04 95%CI: -0.05, 0.13). The number of needle passes showed no statistically significant difference with and without ROSE (RD = -0.68 95%CI: -2.35, 0.98). The pooled sensitivity and specificity of ROSE group were 0.91 (95%CI: 0.87, 0.94) and 1 (95%CI: 0.94, 1.00). The pooled sensitivity and specificity of non-ROSE group were 0.85 (95%CI: 0.80, 0.89) and 1 (95%CI: 0.95, 1.00). ROSE group and non-ROSE group showed comparable sensitivity and specificity. CONCLUSION: Compared to historical reports of its clinical efficacy in patients with pancreatic lesions, ROSE may be not associated with an improvement of diagnostic yield, adequate rate, pooled sensitivity and specificity. Public Library of Science 2016-09-22 /pmc/articles/PMC5033338/ /pubmed/27657529 http://dx.doi.org/10.1371/journal.pone.0163056 Text en © 2016 Kong et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Kong, Fanyang
Zhu, Jianwei
Kong, Xiangyu
Sun, Tao
Deng, Xuan
Du, Yiqi
Li, Zhaoshen
Rapid On-Site Evaluation Does Not Improve Endoscopic Ultrasound-Guided Fine Needle Aspiration Adequacy in Pancreatic Masses: A Meta-Analysis and Systematic Review
title Rapid On-Site Evaluation Does Not Improve Endoscopic Ultrasound-Guided Fine Needle Aspiration Adequacy in Pancreatic Masses: A Meta-Analysis and Systematic Review
title_full Rapid On-Site Evaluation Does Not Improve Endoscopic Ultrasound-Guided Fine Needle Aspiration Adequacy in Pancreatic Masses: A Meta-Analysis and Systematic Review
title_fullStr Rapid On-Site Evaluation Does Not Improve Endoscopic Ultrasound-Guided Fine Needle Aspiration Adequacy in Pancreatic Masses: A Meta-Analysis and Systematic Review
title_full_unstemmed Rapid On-Site Evaluation Does Not Improve Endoscopic Ultrasound-Guided Fine Needle Aspiration Adequacy in Pancreatic Masses: A Meta-Analysis and Systematic Review
title_short Rapid On-Site Evaluation Does Not Improve Endoscopic Ultrasound-Guided Fine Needle Aspiration Adequacy in Pancreatic Masses: A Meta-Analysis and Systematic Review
title_sort rapid on-site evaluation does not improve endoscopic ultrasound-guided fine needle aspiration adequacy in pancreatic masses: a meta-analysis and systematic review
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5033338/
https://www.ncbi.nlm.nih.gov/pubmed/27657529
http://dx.doi.org/10.1371/journal.pone.0163056
work_keys_str_mv AT kongfanyang rapidonsiteevaluationdoesnotimproveendoscopicultrasoundguidedfineneedleaspirationadequacyinpancreaticmassesametaanalysisandsystematicreview
AT zhujianwei rapidonsiteevaluationdoesnotimproveendoscopicultrasoundguidedfineneedleaspirationadequacyinpancreaticmassesametaanalysisandsystematicreview
AT kongxiangyu rapidonsiteevaluationdoesnotimproveendoscopicultrasoundguidedfineneedleaspirationadequacyinpancreaticmassesametaanalysisandsystematicreview
AT suntao rapidonsiteevaluationdoesnotimproveendoscopicultrasoundguidedfineneedleaspirationadequacyinpancreaticmassesametaanalysisandsystematicreview
AT dengxuan rapidonsiteevaluationdoesnotimproveendoscopicultrasoundguidedfineneedleaspirationadequacyinpancreaticmassesametaanalysisandsystematicreview
AT duyiqi rapidonsiteevaluationdoesnotimproveendoscopicultrasoundguidedfineneedleaspirationadequacyinpancreaticmassesametaanalysisandsystematicreview
AT lizhaoshen rapidonsiteevaluationdoesnotimproveendoscopicultrasoundguidedfineneedleaspirationadequacyinpancreaticmassesametaanalysisandsystematicreview