Cargando…

The Water Load Test As a Measure of Gastric Interoception: Development of a Two-Stage Protocol and Application to a Healthy Female Population

The sensitivity for one’s own internal body signals (i.e., interoception) has been demonstrated to play an important role in the pathogenesis of eating and weight disorders. Most previous measures assessing interoceptive processing have not, or only partly, captured perception of hunger and satiety...

Descripción completa

Detalles Bibliográficos
Autores principales: van Dyck, Zoé, Vögele, Claus, Blechert, Jens, Lutz, Annika P. C., Schulz, André, Herbert, Beate M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5033375/
https://www.ncbi.nlm.nih.gov/pubmed/27657528
http://dx.doi.org/10.1371/journal.pone.0163574
_version_ 1782455131357315072
author van Dyck, Zoé
Vögele, Claus
Blechert, Jens
Lutz, Annika P. C.
Schulz, André
Herbert, Beate M.
author_facet van Dyck, Zoé
Vögele, Claus
Blechert, Jens
Lutz, Annika P. C.
Schulz, André
Herbert, Beate M.
author_sort van Dyck, Zoé
collection PubMed
description The sensitivity for one’s own internal body signals (i.e., interoception) has been demonstrated to play an important role in the pathogenesis of eating and weight disorders. Most previous measures assessing interoceptive processing have not, or only partly, captured perception of hunger and satiety cues, which is a core aspect of interoceptive deficits in eating disorders. In addition, methods used to measure sensitivity to gastric signals are heterogeneous and findings inconsistent. The primary aim of the present study was to establish a standardised test to measure gastric interoception, and to provide normative data using a non-clinical adult sample. The two-step Water Load Test (WLT-II) involves ingestion of non-caloric water until perceived satiation (step 1) and until maximum fullness (step 2). The WLT-II consists of several variables: Besides volumes of water ingested until satiation and maximum fullness expressed in ml, percentage of satiation to maximum fullness is calculated as an individual index of gastric interoception that is not confounded with stomach capacity. Ninety-nine healthy women participated in the study. Measures included the WLT-II, the heartbeat tracking test, a self-report questionnaire assessing subjective sensations, and the Eating Disorder Inventory-2. Twenty-eight participants underwent test-retest of the WLT-II. Results suggest that the WLT-II is a valid and reliable measure of gastric interoception. Importantly, satiation volume and percentage of satiation to maximum fullness were strongly positively related to self-reported bulimic symptoms, indicating that the WLT-II could emerge as a useful clinical tool to measure interoceptive processing in the field of eating disorders.
format Online
Article
Text
id pubmed-5033375
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-50333752016-10-10 The Water Load Test As a Measure of Gastric Interoception: Development of a Two-Stage Protocol and Application to a Healthy Female Population van Dyck, Zoé Vögele, Claus Blechert, Jens Lutz, Annika P. C. Schulz, André Herbert, Beate M. PLoS One Research Article The sensitivity for one’s own internal body signals (i.e., interoception) has been demonstrated to play an important role in the pathogenesis of eating and weight disorders. Most previous measures assessing interoceptive processing have not, or only partly, captured perception of hunger and satiety cues, which is a core aspect of interoceptive deficits in eating disorders. In addition, methods used to measure sensitivity to gastric signals are heterogeneous and findings inconsistent. The primary aim of the present study was to establish a standardised test to measure gastric interoception, and to provide normative data using a non-clinical adult sample. The two-step Water Load Test (WLT-II) involves ingestion of non-caloric water until perceived satiation (step 1) and until maximum fullness (step 2). The WLT-II consists of several variables: Besides volumes of water ingested until satiation and maximum fullness expressed in ml, percentage of satiation to maximum fullness is calculated as an individual index of gastric interoception that is not confounded with stomach capacity. Ninety-nine healthy women participated in the study. Measures included the WLT-II, the heartbeat tracking test, a self-report questionnaire assessing subjective sensations, and the Eating Disorder Inventory-2. Twenty-eight participants underwent test-retest of the WLT-II. Results suggest that the WLT-II is a valid and reliable measure of gastric interoception. Importantly, satiation volume and percentage of satiation to maximum fullness were strongly positively related to self-reported bulimic symptoms, indicating that the WLT-II could emerge as a useful clinical tool to measure interoceptive processing in the field of eating disorders. Public Library of Science 2016-09-22 /pmc/articles/PMC5033375/ /pubmed/27657528 http://dx.doi.org/10.1371/journal.pone.0163574 Text en © 2016 van Dyck et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
van Dyck, Zoé
Vögele, Claus
Blechert, Jens
Lutz, Annika P. C.
Schulz, André
Herbert, Beate M.
The Water Load Test As a Measure of Gastric Interoception: Development of a Two-Stage Protocol and Application to a Healthy Female Population
title The Water Load Test As a Measure of Gastric Interoception: Development of a Two-Stage Protocol and Application to a Healthy Female Population
title_full The Water Load Test As a Measure of Gastric Interoception: Development of a Two-Stage Protocol and Application to a Healthy Female Population
title_fullStr The Water Load Test As a Measure of Gastric Interoception: Development of a Two-Stage Protocol and Application to a Healthy Female Population
title_full_unstemmed The Water Load Test As a Measure of Gastric Interoception: Development of a Two-Stage Protocol and Application to a Healthy Female Population
title_short The Water Load Test As a Measure of Gastric Interoception: Development of a Two-Stage Protocol and Application to a Healthy Female Population
title_sort water load test as a measure of gastric interoception: development of a two-stage protocol and application to a healthy female population
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5033375/
https://www.ncbi.nlm.nih.gov/pubmed/27657528
http://dx.doi.org/10.1371/journal.pone.0163574
work_keys_str_mv AT vandyckzoe thewaterloadtestasameasureofgastricinteroceptiondevelopmentofatwostageprotocolandapplicationtoahealthyfemalepopulation
AT vogeleclaus thewaterloadtestasameasureofgastricinteroceptiondevelopmentofatwostageprotocolandapplicationtoahealthyfemalepopulation
AT blechertjens thewaterloadtestasameasureofgastricinteroceptiondevelopmentofatwostageprotocolandapplicationtoahealthyfemalepopulation
AT lutzannikapc thewaterloadtestasameasureofgastricinteroceptiondevelopmentofatwostageprotocolandapplicationtoahealthyfemalepopulation
AT schulzandre thewaterloadtestasameasureofgastricinteroceptiondevelopmentofatwostageprotocolandapplicationtoahealthyfemalepopulation
AT herbertbeatem thewaterloadtestasameasureofgastricinteroceptiondevelopmentofatwostageprotocolandapplicationtoahealthyfemalepopulation
AT vandyckzoe waterloadtestasameasureofgastricinteroceptiondevelopmentofatwostageprotocolandapplicationtoahealthyfemalepopulation
AT vogeleclaus waterloadtestasameasureofgastricinteroceptiondevelopmentofatwostageprotocolandapplicationtoahealthyfemalepopulation
AT blechertjens waterloadtestasameasureofgastricinteroceptiondevelopmentofatwostageprotocolandapplicationtoahealthyfemalepopulation
AT lutzannikapc waterloadtestasameasureofgastricinteroceptiondevelopmentofatwostageprotocolandapplicationtoahealthyfemalepopulation
AT schulzandre waterloadtestasameasureofgastricinteroceptiondevelopmentofatwostageprotocolandapplicationtoahealthyfemalepopulation
AT herbertbeatem waterloadtestasameasureofgastricinteroceptiondevelopmentofatwostageprotocolandapplicationtoahealthyfemalepopulation