Cargando…
Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists
PURPOSE: The purpose of this study was to determine, i) the reliability of blood lactate and ventilatory-based thresholds, ii) the lactate threshold that corresponds with each ventilatory threshold (VT(1) and VT(2)) and with maximal lactate steady state test (MLSS) as a proxy of cycling performance....
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5033582/ https://www.ncbi.nlm.nih.gov/pubmed/27657502 http://dx.doi.org/10.1371/journal.pone.0163389 |
_version_ | 1782455173802622976 |
---|---|
author | Pallarés, Jesús G. Morán-Navarro, Ricardo Ortega, Juan Fernando Fernández-Elías, Valentín Emilio Mora-Rodriguez, Ricardo |
author_facet | Pallarés, Jesús G. Morán-Navarro, Ricardo Ortega, Juan Fernando Fernández-Elías, Valentín Emilio Mora-Rodriguez, Ricardo |
author_sort | Pallarés, Jesús G. |
collection | PubMed |
description | PURPOSE: The purpose of this study was to determine, i) the reliability of blood lactate and ventilatory-based thresholds, ii) the lactate threshold that corresponds with each ventilatory threshold (VT(1) and VT(2)) and with maximal lactate steady state test (MLSS) as a proxy of cycling performance. METHODS: Fourteen aerobically-trained male cyclists ([Image: see text] 62.1±4.6 ml·kg(-1)·min(-1)) performed two graded exercise tests (50 W warm-up followed by 25 W·min(-1)) to exhaustion. Blood lactate, [Image: see text] and [Image: see text] data were collected at every stage. Workloads at VT(1) (rise in [Image: see text] ;) and VT(2) (rise in [Image: see text] ) were compared with workloads at lactate thresholds. Several continuous tests were needed to detect the MLSS workload. Agreement and differences among tests were assessed with ANOVA, ICC and Bland-Altman. Reliability of each test was evaluated using ICC, CV and Bland-Altman plots. RESULTS: Workloads at lactate threshold (LT) and LT+2.0 mMol·L(-1) matched the ones for VT(1) and VT(2), respectively (p = 0.147 and 0.539; r = 0.72 and 0.80; Bias = -13.6 and 2.8, respectively). Furthermore, workload at LT+0.5 mMol·L(-1) coincided with MLSS workload (p = 0.449; r = 0.78; Bias = -4.5). Lactate threshold tests had high reliability (CV = 3.4–3.7%; r = 0.85–0.89; Bias = -2.1–3.0) except for D(MAX) method (CV = 10.3%; r = 0.57; Bias = 15.4). Ventilatory thresholds show high reliability (CV = 1.6%–3.5%; r = 0.90–0.96; Bias = -1.8–2.9) except for RER = 1 and V-Slope (CV = 5.0–6.4%; r = 0.79; Bias = -5.6–12.4). CONCLUSIONS: Lactate threshold tests can be a valid and reliable alternative to ventilatory thresholds to identify the workloads at the transition from aerobic to anaerobic metabolism. |
format | Online Article Text |
id | pubmed-5033582 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-50335822016-10-10 Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists Pallarés, Jesús G. Morán-Navarro, Ricardo Ortega, Juan Fernando Fernández-Elías, Valentín Emilio Mora-Rodriguez, Ricardo PLoS One Research Article PURPOSE: The purpose of this study was to determine, i) the reliability of blood lactate and ventilatory-based thresholds, ii) the lactate threshold that corresponds with each ventilatory threshold (VT(1) and VT(2)) and with maximal lactate steady state test (MLSS) as a proxy of cycling performance. METHODS: Fourteen aerobically-trained male cyclists ([Image: see text] 62.1±4.6 ml·kg(-1)·min(-1)) performed two graded exercise tests (50 W warm-up followed by 25 W·min(-1)) to exhaustion. Blood lactate, [Image: see text] and [Image: see text] data were collected at every stage. Workloads at VT(1) (rise in [Image: see text] ;) and VT(2) (rise in [Image: see text] ) were compared with workloads at lactate thresholds. Several continuous tests were needed to detect the MLSS workload. Agreement and differences among tests were assessed with ANOVA, ICC and Bland-Altman. Reliability of each test was evaluated using ICC, CV and Bland-Altman plots. RESULTS: Workloads at lactate threshold (LT) and LT+2.0 mMol·L(-1) matched the ones for VT(1) and VT(2), respectively (p = 0.147 and 0.539; r = 0.72 and 0.80; Bias = -13.6 and 2.8, respectively). Furthermore, workload at LT+0.5 mMol·L(-1) coincided with MLSS workload (p = 0.449; r = 0.78; Bias = -4.5). Lactate threshold tests had high reliability (CV = 3.4–3.7%; r = 0.85–0.89; Bias = -2.1–3.0) except for D(MAX) method (CV = 10.3%; r = 0.57; Bias = 15.4). Ventilatory thresholds show high reliability (CV = 1.6%–3.5%; r = 0.90–0.96; Bias = -1.8–2.9) except for RER = 1 and V-Slope (CV = 5.0–6.4%; r = 0.79; Bias = -5.6–12.4). CONCLUSIONS: Lactate threshold tests can be a valid and reliable alternative to ventilatory thresholds to identify the workloads at the transition from aerobic to anaerobic metabolism. Public Library of Science 2016-09-22 /pmc/articles/PMC5033582/ /pubmed/27657502 http://dx.doi.org/10.1371/journal.pone.0163389 Text en © 2016 Pallarés et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Pallarés, Jesús G. Morán-Navarro, Ricardo Ortega, Juan Fernando Fernández-Elías, Valentín Emilio Mora-Rodriguez, Ricardo Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists |
title | Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists |
title_full | Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists |
title_fullStr | Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists |
title_full_unstemmed | Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists |
title_short | Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists |
title_sort | validity and reliability of ventilatory and blood lactate thresholds in well-trained cyclists |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5033582/ https://www.ncbi.nlm.nih.gov/pubmed/27657502 http://dx.doi.org/10.1371/journal.pone.0163389 |
work_keys_str_mv | AT pallaresjesusg validityandreliabilityofventilatoryandbloodlactatethresholdsinwelltrainedcyclists AT morannavarroricardo validityandreliabilityofventilatoryandbloodlactatethresholdsinwelltrainedcyclists AT ortegajuanfernando validityandreliabilityofventilatoryandbloodlactatethresholdsinwelltrainedcyclists AT fernandezeliasvalentinemilio validityandreliabilityofventilatoryandbloodlactatethresholdsinwelltrainedcyclists AT morarodriguezricardo validityandreliabilityofventilatoryandbloodlactatethresholdsinwelltrainedcyclists |