Spica magnetic resonance imaging for determination of abduction angle: initial results and reproducibility assessment

PURPOSE: Spica magnectic resonance imaging (MRI) is an established technique for postoperative determination of hip reduction in patients treated for developmental dysplasia of the hip (DDH). A hip abduction angle >55° is considered excessive and has been associated with epiphyseal osteonecrosis....

Descripción completa

Detalles Bibliográficos
Autores principales: Rivlin, M. J., Kan, J. H., Schallert, E. K., Jadhav, S. P., Zhang, W., Rosenfeld, S. B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5033784/
https://www.ncbi.nlm.nih.gov/pubmed/27518845
http://dx.doi.org/10.1007/s11832-016-0765-1
_version_ 1782455187723517952
author Rivlin, M. J.
Kan, J. H.
Schallert, E. K.
Jadhav, S. P.
Zhang, W.
Rosenfeld, S. B.
author_facet Rivlin, M. J.
Kan, J. H.
Schallert, E. K.
Jadhav, S. P.
Zhang, W.
Rosenfeld, S. B.
author_sort Rivlin, M. J.
collection PubMed
description PURPOSE: Spica magnectic resonance imaging (MRI) is an established technique for postoperative determination of hip reduction in patients treated for developmental dysplasia of the hip (DDH). A hip abduction angle >55° is considered excessive and has been associated with epiphyseal osteonecrosis. Our purpose was to establish objective criteria for measuring hip abduction angles on MRI after hip reduction and spica casting in patients with DDH, and evaluate reproducibility and reliability of angle measurement using these criteria. METHODS: Forty patients with DDH at our institution who underwent spica MRI after hip reduction between 3 April 2008 and 3 March 2015 were identified. Hip abduction angles were measured on proton density axial images as follows. A transverse line was drawn connecting the posterior ischial tuberosities. A second line was drawn medially along the distal femoral diaphysis, and the angle between these two lines was measured; this value was subtracted from 90°, yielding the degree of abduction from midline. Measurements were independently performed by three faculty radiologists, one orthopedist, and one radiology resident. Inter-reader and intra-reader reliability was assessed using intraclass correlation (ICC), with 0 representing no agreement and 1 representing perfect agreement. RESULTS: For inter-reader reliability, the ICC of the five physicians was 0.89 (95 % CI 0.84–0.92). For intra-reader reliability, the ICC of the five physicians ranged from 0.90−0.97 (95 % CI 0.85–0.98). The mean standard deviation of hip abduction angle measurement among readers was 3.6°. CONCLUSION: The proposed hip abduction angle measurement criteria for spica MRI are both reproducible and easy to perform. The high ICC and low standard deviation of independently evaluated hip abduction angles indicates high reproducibility of measurement. This applies to both inter- and intra-reader reliability.
format Online
Article
Text
id pubmed-5033784
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-50337842016-10-09 Spica magnetic resonance imaging for determination of abduction angle: initial results and reproducibility assessment Rivlin, M. J. Kan, J. H. Schallert, E. K. Jadhav, S. P. Zhang, W. Rosenfeld, S. B. J Child Orthop Original Clinical Article PURPOSE: Spica magnectic resonance imaging (MRI) is an established technique for postoperative determination of hip reduction in patients treated for developmental dysplasia of the hip (DDH). A hip abduction angle >55° is considered excessive and has been associated with epiphyseal osteonecrosis. Our purpose was to establish objective criteria for measuring hip abduction angles on MRI after hip reduction and spica casting in patients with DDH, and evaluate reproducibility and reliability of angle measurement using these criteria. METHODS: Forty patients with DDH at our institution who underwent spica MRI after hip reduction between 3 April 2008 and 3 March 2015 were identified. Hip abduction angles were measured on proton density axial images as follows. A transverse line was drawn connecting the posterior ischial tuberosities. A second line was drawn medially along the distal femoral diaphysis, and the angle between these two lines was measured; this value was subtracted from 90°, yielding the degree of abduction from midline. Measurements were independently performed by three faculty radiologists, one orthopedist, and one radiology resident. Inter-reader and intra-reader reliability was assessed using intraclass correlation (ICC), with 0 representing no agreement and 1 representing perfect agreement. RESULTS: For inter-reader reliability, the ICC of the five physicians was 0.89 (95 % CI 0.84–0.92). For intra-reader reliability, the ICC of the five physicians ranged from 0.90−0.97 (95 % CI 0.85–0.98). The mean standard deviation of hip abduction angle measurement among readers was 3.6°. CONCLUSION: The proposed hip abduction angle measurement criteria for spica MRI are both reproducible and easy to perform. The high ICC and low standard deviation of independently evaluated hip abduction angles indicates high reproducibility of measurement. This applies to both inter- and intra-reader reliability. Springer Berlin Heidelberg 2016-08-12 2016-10 /pmc/articles/PMC5033784/ /pubmed/27518845 http://dx.doi.org/10.1007/s11832-016-0765-1 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Clinical Article
Rivlin, M. J.
Kan, J. H.
Schallert, E. K.
Jadhav, S. P.
Zhang, W.
Rosenfeld, S. B.
Spica magnetic resonance imaging for determination of abduction angle: initial results and reproducibility assessment
title Spica magnetic resonance imaging for determination of abduction angle: initial results and reproducibility assessment
title_full Spica magnetic resonance imaging for determination of abduction angle: initial results and reproducibility assessment
title_fullStr Spica magnetic resonance imaging for determination of abduction angle: initial results and reproducibility assessment
title_full_unstemmed Spica magnetic resonance imaging for determination of abduction angle: initial results and reproducibility assessment
title_short Spica magnetic resonance imaging for determination of abduction angle: initial results and reproducibility assessment
title_sort spica magnetic resonance imaging for determination of abduction angle: initial results and reproducibility assessment
topic Original Clinical Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5033784/
https://www.ncbi.nlm.nih.gov/pubmed/27518845
http://dx.doi.org/10.1007/s11832-016-0765-1
work_keys_str_mv AT rivlinmj spicamagneticresonanceimagingfordeterminationofabductionangleinitialresultsandreproducibilityassessment
AT kanjh spicamagneticresonanceimagingfordeterminationofabductionangleinitialresultsandreproducibilityassessment
AT schallertek spicamagneticresonanceimagingfordeterminationofabductionangleinitialresultsandreproducibilityassessment
AT jadhavsp spicamagneticresonanceimagingfordeterminationofabductionangleinitialresultsandreproducibilityassessment
AT zhangw spicamagneticresonanceimagingfordeterminationofabductionangleinitialresultsandreproducibilityassessment
AT rosenfeldsb spicamagneticresonanceimagingfordeterminationofabductionangleinitialresultsandreproducibilityassessment