Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation

The intra‐aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre‐, intra‐, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the...

Descripción completa

Detalles Bibliográficos
Autores principales: Bruti, Gianpaolo, Kolyva, Christina, Pepper, John R., Khir, Ashraf W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5034498/
https://www.ncbi.nlm.nih.gov/pubmed/25959284
http://dx.doi.org/10.1111/aor.12509
_version_ 1782455281478795264
author Bruti, Gianpaolo
Kolyva, Christina
Pepper, John R.
Khir, Ashraf W.
author_facet Bruti, Gianpaolo
Kolyva, Christina
Pepper, John R.
Khir, Ashraf W.
author_sort Bruti, Gianpaolo
collection PubMed
description The intra‐aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre‐, intra‐, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi‐recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra‐aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits.
format Online
Article
Text
id pubmed-5034498
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-50344982016-10-03 Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation Bruti, Gianpaolo Kolyva, Christina Pepper, John R. Khir, Ashraf W. Artif Organs Electronic‐Only Articles The intra‐aortic balloon pump (IABP) is a ventricular assist device that is used with a broad range of pre‐, intra‐, and postoperative patients undergoing cardiac surgery. Although the clinical efficacy of the IABP is well documented, the question of reduced efficacy when patients are nursed in the semi‐recumbent position remains outstanding. The aim of the present work is therefore to investigate the underlying mechanics responsible for the loss of IABP performance when operated at an angle to the horizontal. Simultaneous recordings of balloon wall movement, providing an estimate of its diameter (D), and fluid pressure were taken at three sites along the intra‐aortic balloon (IAB) at 0 and 45°. Flow rate, used for the calculation of displaced volume, was also recorded distal to the tip of the balloon. An in vitro experimental setup was used, featuring physiological impedances on either side of the IAB ends. IAB inflation at an angle of 45° showed that D increases at the tip of the IAB first, presenting a resistance to the flow displaced away from the tip of the balloon. The duration of inflation decreased by 15.5%, the inflation pressure pulse decreased by 9.6%, and volume decreased by 2.5%. Similarly, changing the position of the balloon from 0 to 45°, the balloon deflation became slower by 35%, deflation pressure pulse decreased by 14.7%, and volume suctioned was decreased by 15.2%. IAB wall movement showed that operating at 45° results in slower deflation compared with 0°. Slow wall movement, and changes in inflation and deflation onsets, result in a decreased volume displacement and pressure pulse generation. Operating the balloon at an angle to the horizontal, which is the preferred nursing position in intensive care units, results in reduced IAB inflation and deflation performance, possibly compromising its clinical benefits. John Wiley and Sons Inc. 2015-05-08 2015-08 /pmc/articles/PMC5034498/ /pubmed/25959284 http://dx.doi.org/10.1111/aor.12509 Text en Copyright © 2015 The Authors. Artificial Organs published by Wiley Periodicals, Inc. on behalf of International Center for Artificial Organ and Transplantation (ICAOT). This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial (http://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Electronic‐Only Articles
Bruti, Gianpaolo
Kolyva, Christina
Pepper, John R.
Khir, Ashraf W.
Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation
title Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation
title_full Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation
title_fullStr Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation
title_full_unstemmed Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation
title_short Measurements of Intra‐Aortic Balloon Wall Movement During Inflation and Deflation: Effects of Angulation
title_sort measurements of intra‐aortic balloon wall movement during inflation and deflation: effects of angulation
topic Electronic‐Only Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5034498/
https://www.ncbi.nlm.nih.gov/pubmed/25959284
http://dx.doi.org/10.1111/aor.12509
work_keys_str_mv AT brutigianpaolo measurementsofintraaorticballoonwallmovementduringinflationanddeflationeffectsofangulation
AT kolyvachristina measurementsofintraaorticballoonwallmovementduringinflationanddeflationeffectsofangulation
AT pepperjohnr measurementsofintraaorticballoonwallmovementduringinflationanddeflationeffectsofangulation
AT khirashrafw measurementsofintraaorticballoonwallmovementduringinflationanddeflationeffectsofangulation