Cargando…

Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance

BACKGROUND: Test-retest reproducibility is of utmost importance in follow-up of right ventricular (RV) volumes and function; optimal slice orientation though is not yet known. We compared test-retest reproducibility and intra-/inter-observer variability of right ventricular (RV) volumes and function...

Descripción completa

Detalles Bibliográficos
Autores principales: D’Errico, Luigia, Lamacie, Mariana M., Jimenez Juan, Laura, Deva, Djeven, Wald, Rachel M., Ley, Sebastian, Hanneman, Kate, Thavendiranathan, Paaladinesh, Wintersperger, Bernd J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5034656/
https://www.ncbi.nlm.nih.gov/pubmed/27658396
http://dx.doi.org/10.1186/s12968-016-0282-x
_version_ 1782455316232798208
author D’Errico, Luigia
Lamacie, Mariana M.
Jimenez Juan, Laura
Deva, Djeven
Wald, Rachel M.
Ley, Sebastian
Hanneman, Kate
Thavendiranathan, Paaladinesh
Wintersperger, Bernd J.
author_facet D’Errico, Luigia
Lamacie, Mariana M.
Jimenez Juan, Laura
Deva, Djeven
Wald, Rachel M.
Ley, Sebastian
Hanneman, Kate
Thavendiranathan, Paaladinesh
Wintersperger, Bernd J.
author_sort D’Errico, Luigia
collection PubMed
description BACKGROUND: Test-retest reproducibility is of utmost importance in follow-up of right ventricular (RV) volumes and function; optimal slice orientation though is not yet known. We compared test-retest reproducibility and intra-/inter-observer variability of right ventricular (RV) volumes and function assessed with short-axis and transverse cardiovascular magnetic resonance (CMR). METHODS: Eighteen volunteers underwent cine CMR for RV assessment obtaining ventricular coverage in short-axis and transverse slice orientation. Additional 2D phase contrast flow imaging of the main pulmonary artery (MPA) was performed. After complete repositioning repeat acquisitions were performed. Data sets were contoured by two blinded observers. Statistical analysis included Student’s t-test, Bland-Altman plots, intra-class correlation coefficient (ICC) and 2-way ANOVA, SEM and minimal detectable difference calculations. RESULTS: Heart rates (65.0 ± 7.4 vs. 67.6 ± 9.9 bpm; P = 0.1) and MPA flow (89.8 ± 16.6 vs. 87.2 ± 14.9 mL; P = 0.1) did not differ between imaging sessions. EDV and ESV demonstrated an inter-study bias of 0.4 %[−9.5 %,10.3 %] and 2.1 %[−12.3 %,16.4 %] for short-axis and 1.1 %[−7.3 %,9.4 %] and 0.8 %[−16.0 %,17.6 %] for transverse orientation, respectively. There was no significant interaction between imaging orientation and interstudy reproducibility (p = 0.395–0.824), intra-observer variability (p = 0.726–0.862) or inter-observer variability (p = 0.447–0.706) by 2-way ANOVA. Inter-observer agreement by ICC was greater for short axis versus transverse orientation for all parameters (0.769–0.986 vs. 0.625–0.983, respectively). Minimal detectable differences for short axis and transverse orientations were 10.1 mL/11.5 mL for EDV, 8.3 mL/8.4 mL for ESV and 4.1 % vs. 4.7 % for EF, respectively. CONCLUSION: Short-axis and transverse orientation both provide reliable and reproducible measures for follow-up of RV volumes and global function. Therefore, additional transverse SSFP cine CMR may not necessarily be required if performed for the sole purpose of quantitative volumetric RV assessment.
format Online
Article
Text
id pubmed-5034656
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-50346562016-09-29 Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance D’Errico, Luigia Lamacie, Mariana M. Jimenez Juan, Laura Deva, Djeven Wald, Rachel M. Ley, Sebastian Hanneman, Kate Thavendiranathan, Paaladinesh Wintersperger, Bernd J. J Cardiovasc Magn Reson Research BACKGROUND: Test-retest reproducibility is of utmost importance in follow-up of right ventricular (RV) volumes and function; optimal slice orientation though is not yet known. We compared test-retest reproducibility and intra-/inter-observer variability of right ventricular (RV) volumes and function assessed with short-axis and transverse cardiovascular magnetic resonance (CMR). METHODS: Eighteen volunteers underwent cine CMR for RV assessment obtaining ventricular coverage in short-axis and transverse slice orientation. Additional 2D phase contrast flow imaging of the main pulmonary artery (MPA) was performed. After complete repositioning repeat acquisitions were performed. Data sets were contoured by two blinded observers. Statistical analysis included Student’s t-test, Bland-Altman plots, intra-class correlation coefficient (ICC) and 2-way ANOVA, SEM and minimal detectable difference calculations. RESULTS: Heart rates (65.0 ± 7.4 vs. 67.6 ± 9.9 bpm; P = 0.1) and MPA flow (89.8 ± 16.6 vs. 87.2 ± 14.9 mL; P = 0.1) did not differ between imaging sessions. EDV and ESV demonstrated an inter-study bias of 0.4 %[−9.5 %,10.3 %] and 2.1 %[−12.3 %,16.4 %] for short-axis and 1.1 %[−7.3 %,9.4 %] and 0.8 %[−16.0 %,17.6 %] for transverse orientation, respectively. There was no significant interaction between imaging orientation and interstudy reproducibility (p = 0.395–0.824), intra-observer variability (p = 0.726–0.862) or inter-observer variability (p = 0.447–0.706) by 2-way ANOVA. Inter-observer agreement by ICC was greater for short axis versus transverse orientation for all parameters (0.769–0.986 vs. 0.625–0.983, respectively). Minimal detectable differences for short axis and transverse orientations were 10.1 mL/11.5 mL for EDV, 8.3 mL/8.4 mL for ESV and 4.1 % vs. 4.7 % for EF, respectively. CONCLUSION: Short-axis and transverse orientation both provide reliable and reproducible measures for follow-up of RV volumes and global function. Therefore, additional transverse SSFP cine CMR may not necessarily be required if performed for the sole purpose of quantitative volumetric RV assessment. BioMed Central 2016-09-22 /pmc/articles/PMC5034656/ /pubmed/27658396 http://dx.doi.org/10.1186/s12968-016-0282-x Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
D’Errico, Luigia
Lamacie, Mariana M.
Jimenez Juan, Laura
Deva, Djeven
Wald, Rachel M.
Ley, Sebastian
Hanneman, Kate
Thavendiranathan, Paaladinesh
Wintersperger, Bernd J.
Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance
title Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance
title_full Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance
title_fullStr Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance
title_full_unstemmed Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance
title_short Effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse SSFP cine cardiovascular magnetic resonance
title_sort effects of slice orientation on reproducibility of sequential assessment of right ventricular volumes and ejection fraction: short-axis vs transverse ssfp cine cardiovascular magnetic resonance
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5034656/
https://www.ncbi.nlm.nih.gov/pubmed/27658396
http://dx.doi.org/10.1186/s12968-016-0282-x
work_keys_str_mv AT derricoluigia effectsofsliceorientationonreproducibilityofsequentialassessmentofrightventricularvolumesandejectionfractionshortaxisvstransversessfpcinecardiovascularmagneticresonance
AT lamaciemarianam effectsofsliceorientationonreproducibilityofsequentialassessmentofrightventricularvolumesandejectionfractionshortaxisvstransversessfpcinecardiovascularmagneticresonance
AT jimenezjuanlaura effectsofsliceorientationonreproducibilityofsequentialassessmentofrightventricularvolumesandejectionfractionshortaxisvstransversessfpcinecardiovascularmagneticresonance
AT devadjeven effectsofsliceorientationonreproducibilityofsequentialassessmentofrightventricularvolumesandejectionfractionshortaxisvstransversessfpcinecardiovascularmagneticresonance
AT waldrachelm effectsofsliceorientationonreproducibilityofsequentialassessmentofrightventricularvolumesandejectionfractionshortaxisvstransversessfpcinecardiovascularmagneticresonance
AT leysebastian effectsofsliceorientationonreproducibilityofsequentialassessmentofrightventricularvolumesandejectionfractionshortaxisvstransversessfpcinecardiovascularmagneticresonance
AT hannemankate effectsofsliceorientationonreproducibilityofsequentialassessmentofrightventricularvolumesandejectionfractionshortaxisvstransversessfpcinecardiovascularmagneticresonance
AT thavendiranathanpaaladinesh effectsofsliceorientationonreproducibilityofsequentialassessmentofrightventricularvolumesandejectionfractionshortaxisvstransversessfpcinecardiovascularmagneticresonance
AT winterspergerberndj effectsofsliceorientationonreproducibilityofsequentialassessmentofrightventricularvolumesandejectionfractionshortaxisvstransversessfpcinecardiovascularmagneticresonance