Cargando…

A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure

INTRODUCTION: Blindly punching between aorta and right atrium is dangerous. In that case, there is concerned about leakage between the two referred isolate parts. Besides, as the routine imaging techniques (echocardiography or computer tomography) are incompetent to detect this particular anatomic s...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Mingjia, Abdulkadir, Mohamed, Li, Yang, Wei, Xiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AVICENA, d.o.o., Sarajevo 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5034998/
https://www.ncbi.nlm.nih.gov/pubmed/27703300
http://dx.doi.org/10.5455/medarh.2016.70.321-323
_version_ 1782455360730169344
author Ma, Mingjia
Abdulkadir, Mohamed
Li, Yang
Wei, Xiang
author_facet Ma, Mingjia
Abdulkadir, Mohamed
Li, Yang
Wei, Xiang
author_sort Ma, Mingjia
collection PubMed
description INTRODUCTION: Blindly punching between aorta and right atrium is dangerous. In that case, there is concerned about leakage between the two referred isolate parts. Besides, as the routine imaging techniques (echocardiography or computer tomography) are incompetent to detect this particular anatomic structure preoperatively, the intraoperative inspection appears necessary. Our method is useful for identifying this innate fusion plane. CASE REPORT: The thrombosis surrounding prosthesis was detected in the first ultrasound examination after the operation, which was considered to be an indication of successful hemostasis. As the innate fusion between aorta and right atrium appears no rare, the selective creation of left-to-right internal shunt is a valuable maneuver for controlling bleeding in appropriate cases.
format Online
Article
Text
id pubmed-5034998
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher AVICENA, d.o.o., Sarajevo
record_format MEDLINE/PubMed
spelling pubmed-50349982016-10-04 A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure Ma, Mingjia Abdulkadir, Mohamed Li, Yang Wei, Xiang Med Arch Case Report INTRODUCTION: Blindly punching between aorta and right atrium is dangerous. In that case, there is concerned about leakage between the two referred isolate parts. Besides, as the routine imaging techniques (echocardiography or computer tomography) are incompetent to detect this particular anatomic structure preoperatively, the intraoperative inspection appears necessary. Our method is useful for identifying this innate fusion plane. CASE REPORT: The thrombosis surrounding prosthesis was detected in the first ultrasound examination after the operation, which was considered to be an indication of successful hemostasis. As the innate fusion between aorta and right atrium appears no rare, the selective creation of left-to-right internal shunt is a valuable maneuver for controlling bleeding in appropriate cases. AVICENA, d.o.o., Sarajevo 2016-07-27 2016-08 /pmc/articles/PMC5034998/ /pubmed/27703300 http://dx.doi.org/10.5455/medarh.2016.70.321-323 Text en Copyright: © 2016 Mingjia Ma, Mohamed Abdulkadir, Yang Li, and Xiang Wei http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Ma, Mingjia
Abdulkadir, Mohamed
Li, Yang
Wei, Xiang
A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure
title A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure
title_full A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure
title_fullStr A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure
title_full_unstemmed A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure
title_short A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure
title_sort modified wrapping-internal shunt method for hemostasis in bentall procedure
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5034998/
https://www.ncbi.nlm.nih.gov/pubmed/27703300
http://dx.doi.org/10.5455/medarh.2016.70.321-323
work_keys_str_mv AT mamingjia amodifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure
AT abdulkadirmohamed amodifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure
AT liyang amodifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure
AT weixiang amodifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure
AT mamingjia modifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure
AT abdulkadirmohamed modifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure
AT liyang modifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure
AT weixiang modifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure