Cargando…
A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure
INTRODUCTION: Blindly punching between aorta and right atrium is dangerous. In that case, there is concerned about leakage between the two referred isolate parts. Besides, as the routine imaging techniques (echocardiography or computer tomography) are incompetent to detect this particular anatomic s...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AVICENA, d.o.o., Sarajevo
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5034998/ https://www.ncbi.nlm.nih.gov/pubmed/27703300 http://dx.doi.org/10.5455/medarh.2016.70.321-323 |
_version_ | 1782455360730169344 |
---|---|
author | Ma, Mingjia Abdulkadir, Mohamed Li, Yang Wei, Xiang |
author_facet | Ma, Mingjia Abdulkadir, Mohamed Li, Yang Wei, Xiang |
author_sort | Ma, Mingjia |
collection | PubMed |
description | INTRODUCTION: Blindly punching between aorta and right atrium is dangerous. In that case, there is concerned about leakage between the two referred isolate parts. Besides, as the routine imaging techniques (echocardiography or computer tomography) are incompetent to detect this particular anatomic structure preoperatively, the intraoperative inspection appears necessary. Our method is useful for identifying this innate fusion plane. CASE REPORT: The thrombosis surrounding prosthesis was detected in the first ultrasound examination after the operation, which was considered to be an indication of successful hemostasis. As the innate fusion between aorta and right atrium appears no rare, the selective creation of left-to-right internal shunt is a valuable maneuver for controlling bleeding in appropriate cases. |
format | Online Article Text |
id | pubmed-5034998 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | AVICENA, d.o.o., Sarajevo |
record_format | MEDLINE/PubMed |
spelling | pubmed-50349982016-10-04 A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure Ma, Mingjia Abdulkadir, Mohamed Li, Yang Wei, Xiang Med Arch Case Report INTRODUCTION: Blindly punching between aorta and right atrium is dangerous. In that case, there is concerned about leakage between the two referred isolate parts. Besides, as the routine imaging techniques (echocardiography or computer tomography) are incompetent to detect this particular anatomic structure preoperatively, the intraoperative inspection appears necessary. Our method is useful for identifying this innate fusion plane. CASE REPORT: The thrombosis surrounding prosthesis was detected in the first ultrasound examination after the operation, which was considered to be an indication of successful hemostasis. As the innate fusion between aorta and right atrium appears no rare, the selective creation of left-to-right internal shunt is a valuable maneuver for controlling bleeding in appropriate cases. AVICENA, d.o.o., Sarajevo 2016-07-27 2016-08 /pmc/articles/PMC5034998/ /pubmed/27703300 http://dx.doi.org/10.5455/medarh.2016.70.321-323 Text en Copyright: © 2016 Mingjia Ma, Mohamed Abdulkadir, Yang Li, and Xiang Wei http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Ma, Mingjia Abdulkadir, Mohamed Li, Yang Wei, Xiang A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure |
title | A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure |
title_full | A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure |
title_fullStr | A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure |
title_full_unstemmed | A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure |
title_short | A Modified Wrapping-internal Shunt Method for Hemostasis in Bentall Procedure |
title_sort | modified wrapping-internal shunt method for hemostasis in bentall procedure |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5034998/ https://www.ncbi.nlm.nih.gov/pubmed/27703300 http://dx.doi.org/10.5455/medarh.2016.70.321-323 |
work_keys_str_mv | AT mamingjia amodifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure AT abdulkadirmohamed amodifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure AT liyang amodifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure AT weixiang amodifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure AT mamingjia modifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure AT abdulkadirmohamed modifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure AT liyang modifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure AT weixiang modifiedwrappinginternalshuntmethodforhemostasisinbentallprocedure |