Cargando…
Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes
BACKGROUND: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. OBJECTIVES: This study aimed to evaluate the functional and radiological outco...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kowsar
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5035514/ https://www.ncbi.nlm.nih.gov/pubmed/27679785 http://dx.doi.org/10.5812/atr.25174 |
_version_ | 1782455428598202368 |
---|---|
author | Khatri, Kavin Sharma, Vijay Farooque, Kamran Tiwari, Vivek |
author_facet | Khatri, Kavin Sharma, Vijay Farooque, Kamran Tiwari, Vivek |
author_sort | Khatri, Kavin |
collection | PubMed |
description | BACKGROUND: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. OBJECTIVES: This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. PATIENTS AND METHODS: We reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. The mean age of the patients was 32.82 ± 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 ± 2.47 months (range 6 to 15). All of the patients underwent open reduction and internal fixation with a variable-angle locking plate. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley’s demerit scoring system was used to assess the final outcome. RESULTS: There were two cases of superficial infection that responded to oral antibiotics. One patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases. CONCLUSIONS: The use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications. |
format | Online Article Text |
id | pubmed-5035514 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Kowsar |
record_format | MEDLINE/PubMed |
spelling | pubmed-50355142016-09-27 Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes Khatri, Kavin Sharma, Vijay Farooque, Kamran Tiwari, Vivek Arch Trauma Res Research Article BACKGROUND: Unstable distal end radius fractures are difficult to manage and so various treatment modalities have been described. The use of variable-angle locking plates is promoted for the management of these fractures. OBJECTIVES: This study aimed to evaluate the functional and radiological outcomes in unstable distal end radius fractures treated with variable-angle locking plates. PATIENTS AND METHODS: We reviewed 23 unstable distal end radius fractures that were treated at our institution with volar variable-angle locking plates. The mean age of the patients was 32.82 ± 11.81 years (range 19 to 62) and the mean duration of follow-up was 11.04 ± 2.47 months (range 6 to 15). All of the patients underwent open reduction and internal fixation with a variable-angle locking plate. Radiological parameters such as radial inclination, length, tilt, and ulnar variance were measured at six weeks and at the final follow-up. The functional evaluation was conducted by measuring the range of motion at the wrist joint as well as the grip strength. Gartland and Werley’s demerit scoring system was used to assess the final outcome. RESULTS: There were two cases of superficial infection that responded to oral antibiotics. One patient had developed a hypertrophic scar, while another had carpal tunnel syndrome that was conservatively managed. There was a significant improvement in the functional indices from six weeks to the final follow-up, while the radiological parameters were maintained. According to Gartland and Werley, excellent results were reported in 65.2% cases, while good results were present in 35% cases. CONCLUSIONS: The use of variable-angle locking plates in treating unstable distal end radius fractures is associated with excellent to good functional outcomes with minimal complications. Kowsar 2016-05-09 /pmc/articles/PMC5035514/ /pubmed/27679785 http://dx.doi.org/10.5812/atr.25174 Text en Copyright © 2016, Kashan University of Medical Sciences http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited. |
spellingShingle | Research Article Khatri, Kavin Sharma, Vijay Farooque, Kamran Tiwari, Vivek Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes |
title | Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes |
title_full | Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes |
title_fullStr | Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes |
title_full_unstemmed | Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes |
title_short | Surgical Treatment of Unstable Distal Radius Fractures With a Volar Variable-Angle Locking Plate: Clinical and Radiological Outcomes |
title_sort | surgical treatment of unstable distal radius fractures with a volar variable-angle locking plate: clinical and radiological outcomes |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5035514/ https://www.ncbi.nlm.nih.gov/pubmed/27679785 http://dx.doi.org/10.5812/atr.25174 |
work_keys_str_mv | AT khatrikavin surgicaltreatmentofunstabledistalradiusfractureswithavolarvariableanglelockingplateclinicalandradiologicaloutcomes AT sharmavijay surgicaltreatmentofunstabledistalradiusfractureswithavolarvariableanglelockingplateclinicalandradiologicaloutcomes AT farooquekamran surgicaltreatmentofunstabledistalradiusfractureswithavolarvariableanglelockingplateclinicalandradiologicaloutcomes AT tiwarivivek surgicaltreatmentofunstabledistalradiusfractureswithavolarvariableanglelockingplateclinicalandradiologicaloutcomes |