Cargando…

Left Ventricular Function Evaluation on a 3T MR Scanner with Parallel RF Transmission Technique: Prospective Comparison of Cine Sequences Acquired before and after Gadolinium Injection

OBJECTIVES: To compare cine MR b-TFE sequences acquired before and after gadolinium injection, on a 3T scanner with a parallel RF transmission technique in order to potentially improve scanning time efficiency when evaluating LV function. METHODS: 25 consecutive patients scheduled for a cardiac MRI...

Descripción completa

Detalles Bibliográficos
Autores principales: Caspar, Thibault, Schultz, Anthony, Schaeffer, Mickaël, Labani, Aïssam, Jeung, Mi-Young, Jurgens, Paul Thomas, El Ghannudi, Soraya, Roy, Catherine, Ohana, Mickaël
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5036819/
https://www.ncbi.nlm.nih.gov/pubmed/27669571
http://dx.doi.org/10.1371/journal.pone.0163503
_version_ 1782455630509899776
author Caspar, Thibault
Schultz, Anthony
Schaeffer, Mickaël
Labani, Aïssam
Jeung, Mi-Young
Jurgens, Paul Thomas
El Ghannudi, Soraya
Roy, Catherine
Ohana, Mickaël
author_facet Caspar, Thibault
Schultz, Anthony
Schaeffer, Mickaël
Labani, Aïssam
Jeung, Mi-Young
Jurgens, Paul Thomas
El Ghannudi, Soraya
Roy, Catherine
Ohana, Mickaël
author_sort Caspar, Thibault
collection PubMed
description OBJECTIVES: To compare cine MR b-TFE sequences acquired before and after gadolinium injection, on a 3T scanner with a parallel RF transmission technique in order to potentially improve scanning time efficiency when evaluating LV function. METHODS: 25 consecutive patients scheduled for a cardiac MRI were prospectively included and had their b-TFE cine sequences acquired before and right after gadobutrol injection. Images were assessed qualitatively (overall image quality, LV edge sharpness, artifacts and LV wall motion) and quantitatively with measurement of LVEF, LV mass, and telediastolic volume and contrast-to-noise ratio (CNR) between the myocardium and the cardiac chamber. Statistical analysis was conducted using a Bayesian paradigm. RESULTS: No difference was found before or after injection for the LVEF, LV mass and telediastolic volume evaluations. Overall image quality and CNR were significantly lower after injection (estimated coefficient cine after > cine before gadolinium: -1.75 CI = [-3.78;-0.0305], prob(coef>0) = 0% and -0.23 CI = [-0.49;0.04], prob(coef>0) = 4%) respectively), but this decrease did not affect the visual assessment of LV wall motion (cine after > cine before gadolinium: -1.46 CI = [-4.72;1.13], prob(coef>0) = 15%). CONCLUSIONS: In 3T cardiac MRI acquired with parallel RF transmission technique, qualitative and quantitative assessment of LV function can reliably be performed with cine sequences acquired after gadolinium injection, despite a significant decrease in the CNR and the overall image quality.
format Online
Article
Text
id pubmed-5036819
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-50368192016-10-27 Left Ventricular Function Evaluation on a 3T MR Scanner with Parallel RF Transmission Technique: Prospective Comparison of Cine Sequences Acquired before and after Gadolinium Injection Caspar, Thibault Schultz, Anthony Schaeffer, Mickaël Labani, Aïssam Jeung, Mi-Young Jurgens, Paul Thomas El Ghannudi, Soraya Roy, Catherine Ohana, Mickaël PLoS One Research Article OBJECTIVES: To compare cine MR b-TFE sequences acquired before and after gadolinium injection, on a 3T scanner with a parallel RF transmission technique in order to potentially improve scanning time efficiency when evaluating LV function. METHODS: 25 consecutive patients scheduled for a cardiac MRI were prospectively included and had their b-TFE cine sequences acquired before and right after gadobutrol injection. Images were assessed qualitatively (overall image quality, LV edge sharpness, artifacts and LV wall motion) and quantitatively with measurement of LVEF, LV mass, and telediastolic volume and contrast-to-noise ratio (CNR) between the myocardium and the cardiac chamber. Statistical analysis was conducted using a Bayesian paradigm. RESULTS: No difference was found before or after injection for the LVEF, LV mass and telediastolic volume evaluations. Overall image quality and CNR were significantly lower after injection (estimated coefficient cine after > cine before gadolinium: -1.75 CI = [-3.78;-0.0305], prob(coef>0) = 0% and -0.23 CI = [-0.49;0.04], prob(coef>0) = 4%) respectively), but this decrease did not affect the visual assessment of LV wall motion (cine after > cine before gadolinium: -1.46 CI = [-4.72;1.13], prob(coef>0) = 15%). CONCLUSIONS: In 3T cardiac MRI acquired with parallel RF transmission technique, qualitative and quantitative assessment of LV function can reliably be performed with cine sequences acquired after gadolinium injection, despite a significant decrease in the CNR and the overall image quality. Public Library of Science 2016-09-26 /pmc/articles/PMC5036819/ /pubmed/27669571 http://dx.doi.org/10.1371/journal.pone.0163503 Text en © 2016 Caspar et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Caspar, Thibault
Schultz, Anthony
Schaeffer, Mickaël
Labani, Aïssam
Jeung, Mi-Young
Jurgens, Paul Thomas
El Ghannudi, Soraya
Roy, Catherine
Ohana, Mickaël
Left Ventricular Function Evaluation on a 3T MR Scanner with Parallel RF Transmission Technique: Prospective Comparison of Cine Sequences Acquired before and after Gadolinium Injection
title Left Ventricular Function Evaluation on a 3T MR Scanner with Parallel RF Transmission Technique: Prospective Comparison of Cine Sequences Acquired before and after Gadolinium Injection
title_full Left Ventricular Function Evaluation on a 3T MR Scanner with Parallel RF Transmission Technique: Prospective Comparison of Cine Sequences Acquired before and after Gadolinium Injection
title_fullStr Left Ventricular Function Evaluation on a 3T MR Scanner with Parallel RF Transmission Technique: Prospective Comparison of Cine Sequences Acquired before and after Gadolinium Injection
title_full_unstemmed Left Ventricular Function Evaluation on a 3T MR Scanner with Parallel RF Transmission Technique: Prospective Comparison of Cine Sequences Acquired before and after Gadolinium Injection
title_short Left Ventricular Function Evaluation on a 3T MR Scanner with Parallel RF Transmission Technique: Prospective Comparison of Cine Sequences Acquired before and after Gadolinium Injection
title_sort left ventricular function evaluation on a 3t mr scanner with parallel rf transmission technique: prospective comparison of cine sequences acquired before and after gadolinium injection
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5036819/
https://www.ncbi.nlm.nih.gov/pubmed/27669571
http://dx.doi.org/10.1371/journal.pone.0163503
work_keys_str_mv AT casparthibault leftventricularfunctionevaluationona3tmrscannerwithparallelrftransmissiontechniqueprospectivecomparisonofcinesequencesacquiredbeforeandaftergadoliniuminjection
AT schultzanthony leftventricularfunctionevaluationona3tmrscannerwithparallelrftransmissiontechniqueprospectivecomparisonofcinesequencesacquiredbeforeandaftergadoliniuminjection
AT schaeffermickael leftventricularfunctionevaluationona3tmrscannerwithparallelrftransmissiontechniqueprospectivecomparisonofcinesequencesacquiredbeforeandaftergadoliniuminjection
AT labaniaissam leftventricularfunctionevaluationona3tmrscannerwithparallelrftransmissiontechniqueprospectivecomparisonofcinesequencesacquiredbeforeandaftergadoliniuminjection
AT jeungmiyoung leftventricularfunctionevaluationona3tmrscannerwithparallelrftransmissiontechniqueprospectivecomparisonofcinesequencesacquiredbeforeandaftergadoliniuminjection
AT jurgenspaulthomas leftventricularfunctionevaluationona3tmrscannerwithparallelrftransmissiontechniqueprospectivecomparisonofcinesequencesacquiredbeforeandaftergadoliniuminjection
AT elghannudisoraya leftventricularfunctionevaluationona3tmrscannerwithparallelrftransmissiontechniqueprospectivecomparisonofcinesequencesacquiredbeforeandaftergadoliniuminjection
AT roycatherine leftventricularfunctionevaluationona3tmrscannerwithparallelrftransmissiontechniqueprospectivecomparisonofcinesequencesacquiredbeforeandaftergadoliniuminjection
AT ohanamickael leftventricularfunctionevaluationona3tmrscannerwithparallelrftransmissiontechniqueprospectivecomparisonofcinesequencesacquiredbeforeandaftergadoliniuminjection