Cargando…

The effect of contouring on fatigue resistance of three types of fracture fixation plates

BACKGROUND: Metallic reconstruction plates used for fracture stabilization typically require intraoperative contouring for patient-specific anatomical fit. Despite this, characterization of plate mechanical properties after contouring has previously been limited. The objective of this study was to a...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Angela S. P., Fechter, Chelsea M., Magill, Mark, Wipf, Felix, Moore, Thomas, Guldberg, Robert E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5037585/
https://www.ncbi.nlm.nih.gov/pubmed/27671529
http://dx.doi.org/10.1186/s13018-016-0439-1
_version_ 1782455768102993920
author Lin, Angela S. P.
Fechter, Chelsea M.
Magill, Mark
Wipf, Felix
Moore, Thomas
Guldberg, Robert E.
author_facet Lin, Angela S. P.
Fechter, Chelsea M.
Magill, Mark
Wipf, Felix
Moore, Thomas
Guldberg, Robert E.
author_sort Lin, Angela S. P.
collection PubMed
description BACKGROUND: Metallic reconstruction plates used for fracture stabilization typically require intraoperative contouring for patient-specific anatomical fit. Despite this, characterization of plate mechanical properties after contouring has previously been limited. The objective of this study was to assess whether contouring affects fatigue resistance for three types of Stryker seven-hole stainless steel (SS) 316LVM fracture fixation plates. The hypothesis was that for each plate type, more contouring repetitions would result in lower fatigue resistance. METHODS: Plates were contoured using a bench-top plate bender to ±20° either 0×, 3×, 6×, or 9× (n = 5 per group) and tested in the straight configuration. Cyclic four-point bending was applied in an incremental stepwise staircase approach (one step = 100,000 cycles, 10 Hz) until failure (defined as brittle fracture or plastic deformation of 10° permanent bend). Moment-cycle product (MCP) was computed as the summation of maximum moment × number of cycles and used as the primary measure of fatigue resistance. RESULTS: No significant differences in fatigue resistance were detected between contouring groups for Basic Fragment Set (BFS) Reconstruction Plates. Significantly lower fatigue resistance was measured for 9× contoured Matta Pelvic System (MPS) Straight Plates compared to 0× contoured plates (p = 0.023). MPS Flex Plates contoured 3× had greater fatigue resistance than 0× contoured (p = 0.031) and 9× contoured plates (p = 0.032). CONCLUSIONS: This work provides fatigue resistance-based evidence that clinicians should avoid high repetitions of contouring for MPS Straight Plates. Meanwhile, BFS Reconstruction Plates and MPS Flex Plates are not negatively affected by contouring. These results allow for improved intraoperative decisions about using or discarding plates after multiple contouring repetitions.
format Online
Article
Text
id pubmed-5037585
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-50375852016-10-05 The effect of contouring on fatigue resistance of three types of fracture fixation plates Lin, Angela S. P. Fechter, Chelsea M. Magill, Mark Wipf, Felix Moore, Thomas Guldberg, Robert E. J Orthop Surg Res Research Article BACKGROUND: Metallic reconstruction plates used for fracture stabilization typically require intraoperative contouring for patient-specific anatomical fit. Despite this, characterization of plate mechanical properties after contouring has previously been limited. The objective of this study was to assess whether contouring affects fatigue resistance for three types of Stryker seven-hole stainless steel (SS) 316LVM fracture fixation plates. The hypothesis was that for each plate type, more contouring repetitions would result in lower fatigue resistance. METHODS: Plates were contoured using a bench-top plate bender to ±20° either 0×, 3×, 6×, or 9× (n = 5 per group) and tested in the straight configuration. Cyclic four-point bending was applied in an incremental stepwise staircase approach (one step = 100,000 cycles, 10 Hz) until failure (defined as brittle fracture or plastic deformation of 10° permanent bend). Moment-cycle product (MCP) was computed as the summation of maximum moment × number of cycles and used as the primary measure of fatigue resistance. RESULTS: No significant differences in fatigue resistance were detected between contouring groups for Basic Fragment Set (BFS) Reconstruction Plates. Significantly lower fatigue resistance was measured for 9× contoured Matta Pelvic System (MPS) Straight Plates compared to 0× contoured plates (p = 0.023). MPS Flex Plates contoured 3× had greater fatigue resistance than 0× contoured (p = 0.031) and 9× contoured plates (p = 0.032). CONCLUSIONS: This work provides fatigue resistance-based evidence that clinicians should avoid high repetitions of contouring for MPS Straight Plates. Meanwhile, BFS Reconstruction Plates and MPS Flex Plates are not negatively affected by contouring. These results allow for improved intraoperative decisions about using or discarding plates after multiple contouring repetitions. BioMed Central 2016-09-26 /pmc/articles/PMC5037585/ /pubmed/27671529 http://dx.doi.org/10.1186/s13018-016-0439-1 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Lin, Angela S. P.
Fechter, Chelsea M.
Magill, Mark
Wipf, Felix
Moore, Thomas
Guldberg, Robert E.
The effect of contouring on fatigue resistance of three types of fracture fixation plates
title The effect of contouring on fatigue resistance of three types of fracture fixation plates
title_full The effect of contouring on fatigue resistance of three types of fracture fixation plates
title_fullStr The effect of contouring on fatigue resistance of three types of fracture fixation plates
title_full_unstemmed The effect of contouring on fatigue resistance of three types of fracture fixation plates
title_short The effect of contouring on fatigue resistance of three types of fracture fixation plates
title_sort effect of contouring on fatigue resistance of three types of fracture fixation plates
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5037585/
https://www.ncbi.nlm.nih.gov/pubmed/27671529
http://dx.doi.org/10.1186/s13018-016-0439-1
work_keys_str_mv AT linangelasp theeffectofcontouringonfatigueresistanceofthreetypesoffracturefixationplates
AT fechterchelseam theeffectofcontouringonfatigueresistanceofthreetypesoffracturefixationplates
AT magillmark theeffectofcontouringonfatigueresistanceofthreetypesoffracturefixationplates
AT wipffelix theeffectofcontouringonfatigueresistanceofthreetypesoffracturefixationplates
AT moorethomas theeffectofcontouringonfatigueresistanceofthreetypesoffracturefixationplates
AT guldbergroberte theeffectofcontouringonfatigueresistanceofthreetypesoffracturefixationplates
AT linangelasp effectofcontouringonfatigueresistanceofthreetypesoffracturefixationplates
AT fechterchelseam effectofcontouringonfatigueresistanceofthreetypesoffracturefixationplates
AT magillmark effectofcontouringonfatigueresistanceofthreetypesoffracturefixationplates
AT wipffelix effectofcontouringonfatigueresistanceofthreetypesoffracturefixationplates
AT moorethomas effectofcontouringonfatigueresistanceofthreetypesoffracturefixationplates
AT guldbergroberte effectofcontouringonfatigueresistanceofthreetypesoffracturefixationplates