Cargando…

Comparison of the accuracy of (99m)Tc-3P(4)-RGD(2) SPECT and CT in diagnosing solitary pulmonary nodules

The aim of the present study was to compare technetium-99m-(polyethylene glycol-4)(3)-(Arg-Gly-Asp)(2) (99mTc-3P(4)-RGD(2)) single-photon emission computed tomography (SPECT) and computed tomography (CT) in the noninvasive differentiation of solitary pulmonary nodules (SPNs). The present study prosp...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Haishan, Gao, Shi, Chen, Bin, Cheng, Guanghui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5038481/
https://www.ncbi.nlm.nih.gov/pubmed/27698821
http://dx.doi.org/10.3892/ol.2016.5030
_version_ 1782455900121858048
author Zhang, Haishan
Gao, Shi
Chen, Bin
Cheng, Guanghui
author_facet Zhang, Haishan
Gao, Shi
Chen, Bin
Cheng, Guanghui
author_sort Zhang, Haishan
collection PubMed
description The aim of the present study was to compare technetium-99m-(polyethylene glycol-4)(3)-(Arg-Gly-Asp)(2) (99mTc-3P(4)-RGD(2)) single-photon emission computed tomography (SPECT) and computed tomography (CT) in the noninvasive differentiation of solitary pulmonary nodules (SPNs). The present study prospectively investigated a consecutive series of 24 patients with SPN, who were newly diagnosed using radiography between September 2012 and January 2014. All patients underwent 99mTc-3P(4)-RGD(2) SPECT and CT scans using a dual-head variable-angle γ-camera equipped with high-resolution collimators. A blinded panel of two thoracic radiologists for CT and three nuclear physicians for SPECT analyzed the images using a 5-grade scale. The SPECT images were also semi-quantitatively evaluated using tumor to non-tumor localization ratios (T/NT). The results were verified by pathological examination of the biopsy material obtained from each patient with SPN, and receiver operating characteristic (ROC) curves were generated from these results. The present results revealed that there were 17 malignant and 7 benign SPNs among the 24 patients with SPN. The mean size of the SPN was 2.1±0.6 cm. Sensitivity of visual analysis for SPECT and CT were 100.0 and 82.4%, respectively, and specificity was 71.4% for the two methods. When the T/NT SPECT semiquantitative analysis (ratio, 1.64) was used as a cut-off, the sensitivity and specificity of SPECT were 100.0 and 71.4%, respectively. The areas under the ROC curves were 0.840 for visual analysis of SPECT [95% confidence interval (CI), 0.600–1.000], 0.849 for semiquantitative analysis of SPECT (95% CI, 0.618–1.000) and 0.815 for CT (95% CI, 0.626–1.000). In conclusion, the present results suggest that 99mTc-3P(4)-RGD(2) SPECT is more accurate than CT in the detection of malignant SPN, and visual analysis appears to be sufficient for the characterization of SPN.
format Online
Article
Text
id pubmed-5038481
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-50384812016-10-03 Comparison of the accuracy of (99m)Tc-3P(4)-RGD(2) SPECT and CT in diagnosing solitary pulmonary nodules Zhang, Haishan Gao, Shi Chen, Bin Cheng, Guanghui Oncol Lett Articles The aim of the present study was to compare technetium-99m-(polyethylene glycol-4)(3)-(Arg-Gly-Asp)(2) (99mTc-3P(4)-RGD(2)) single-photon emission computed tomography (SPECT) and computed tomography (CT) in the noninvasive differentiation of solitary pulmonary nodules (SPNs). The present study prospectively investigated a consecutive series of 24 patients with SPN, who were newly diagnosed using radiography between September 2012 and January 2014. All patients underwent 99mTc-3P(4)-RGD(2) SPECT and CT scans using a dual-head variable-angle γ-camera equipped with high-resolution collimators. A blinded panel of two thoracic radiologists for CT and three nuclear physicians for SPECT analyzed the images using a 5-grade scale. The SPECT images were also semi-quantitatively evaluated using tumor to non-tumor localization ratios (T/NT). The results were verified by pathological examination of the biopsy material obtained from each patient with SPN, and receiver operating characteristic (ROC) curves were generated from these results. The present results revealed that there were 17 malignant and 7 benign SPNs among the 24 patients with SPN. The mean size of the SPN was 2.1±0.6 cm. Sensitivity of visual analysis for SPECT and CT were 100.0 and 82.4%, respectively, and specificity was 71.4% for the two methods. When the T/NT SPECT semiquantitative analysis (ratio, 1.64) was used as a cut-off, the sensitivity and specificity of SPECT were 100.0 and 71.4%, respectively. The areas under the ROC curves were 0.840 for visual analysis of SPECT [95% confidence interval (CI), 0.600–1.000], 0.849 for semiquantitative analysis of SPECT (95% CI, 0.618–1.000) and 0.815 for CT (95% CI, 0.626–1.000). In conclusion, the present results suggest that 99mTc-3P(4)-RGD(2) SPECT is more accurate than CT in the detection of malignant SPN, and visual analysis appears to be sufficient for the characterization of SPN. D.A. Spandidos 2016-10 2016-08-17 /pmc/articles/PMC5038481/ /pubmed/27698821 http://dx.doi.org/10.3892/ol.2016.5030 Text en Copyright: © Zhang et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Zhang, Haishan
Gao, Shi
Chen, Bin
Cheng, Guanghui
Comparison of the accuracy of (99m)Tc-3P(4)-RGD(2) SPECT and CT in diagnosing solitary pulmonary nodules
title Comparison of the accuracy of (99m)Tc-3P(4)-RGD(2) SPECT and CT in diagnosing solitary pulmonary nodules
title_full Comparison of the accuracy of (99m)Tc-3P(4)-RGD(2) SPECT and CT in diagnosing solitary pulmonary nodules
title_fullStr Comparison of the accuracy of (99m)Tc-3P(4)-RGD(2) SPECT and CT in diagnosing solitary pulmonary nodules
title_full_unstemmed Comparison of the accuracy of (99m)Tc-3P(4)-RGD(2) SPECT and CT in diagnosing solitary pulmonary nodules
title_short Comparison of the accuracy of (99m)Tc-3P(4)-RGD(2) SPECT and CT in diagnosing solitary pulmonary nodules
title_sort comparison of the accuracy of (99m)tc-3p(4)-rgd(2) spect and ct in diagnosing solitary pulmonary nodules
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5038481/
https://www.ncbi.nlm.nih.gov/pubmed/27698821
http://dx.doi.org/10.3892/ol.2016.5030
work_keys_str_mv AT zhanghaishan comparisonoftheaccuracyof99mtc3p4rgd2spectandctindiagnosingsolitarypulmonarynodules
AT gaoshi comparisonoftheaccuracyof99mtc3p4rgd2spectandctindiagnosingsolitarypulmonarynodules
AT chenbin comparisonoftheaccuracyof99mtc3p4rgd2spectandctindiagnosingsolitarypulmonarynodules
AT chengguanghui comparisonoftheaccuracyof99mtc3p4rgd2spectandctindiagnosingsolitarypulmonarynodules