Cargando…
Sensitive Bioanalysis Based on in-Situ Droplet Anodic Stripping Voltammetric Detection of CdS Quantum Dots Label after Enhanced Cathodic Preconcentration
We report a protocol of CdS-labeled sandwich-type amperometric bioanalysis with high sensitivity, on the basis of simultaneous chemical-dissolution/cathodic-enrichment of the CdS quantum dot biolabel and anodic stripping voltammetry (ASV) detection of Cd directly on the bioelectrode. We added a micr...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5038621/ https://www.ncbi.nlm.nih.gov/pubmed/27563894 http://dx.doi.org/10.3390/s16091342 |
_version_ | 1782455914668752896 |
---|---|
author | Qin, Xiaoli Wang, Linchun Xie, Qingji |
author_facet | Qin, Xiaoli Wang, Linchun Xie, Qingji |
author_sort | Qin, Xiaoli |
collection | PubMed |
description | We report a protocol of CdS-labeled sandwich-type amperometric bioanalysis with high sensitivity, on the basis of simultaneous chemical-dissolution/cathodic-enrichment of the CdS quantum dot biolabel and anodic stripping voltammetry (ASV) detection of Cd directly on the bioelectrode. We added a microliter droplet of 0.1 M aqueous HNO(3) to dissolve CdS on the bioelectrode and simultaneously achieved the potentiostatic cathodic preconcentration of Cd by starting the potentiostatic operation before HNO(3) addition, which can largely increase the ASV signal. Our protocol was used for immunoanalysis and aptamer-based bioanalysis of several proteins, giving limits of detection of 4.5 fg·mL(−1) for human immunoglobulin G, 3.0 fg·mL(−1) for human carcinoembryonic antigen (CEA), 4.9 fg·mL(−1) for human α-fetoprotein (AFP), and 0.9 fM for thrombin, which are better than many reported results. The simultaneous and sensitive analysis of CEA and AFP at two screen-printed carbon electrodes was also conducted by our protocol. |
format | Online Article Text |
id | pubmed-5038621 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-50386212016-09-29 Sensitive Bioanalysis Based on in-Situ Droplet Anodic Stripping Voltammetric Detection of CdS Quantum Dots Label after Enhanced Cathodic Preconcentration Qin, Xiaoli Wang, Linchun Xie, Qingji Sensors (Basel) Article We report a protocol of CdS-labeled sandwich-type amperometric bioanalysis with high sensitivity, on the basis of simultaneous chemical-dissolution/cathodic-enrichment of the CdS quantum dot biolabel and anodic stripping voltammetry (ASV) detection of Cd directly on the bioelectrode. We added a microliter droplet of 0.1 M aqueous HNO(3) to dissolve CdS on the bioelectrode and simultaneously achieved the potentiostatic cathodic preconcentration of Cd by starting the potentiostatic operation before HNO(3) addition, which can largely increase the ASV signal. Our protocol was used for immunoanalysis and aptamer-based bioanalysis of several proteins, giving limits of detection of 4.5 fg·mL(−1) for human immunoglobulin G, 3.0 fg·mL(−1) for human carcinoembryonic antigen (CEA), 4.9 fg·mL(−1) for human α-fetoprotein (AFP), and 0.9 fM for thrombin, which are better than many reported results. The simultaneous and sensitive analysis of CEA and AFP at two screen-printed carbon electrodes was also conducted by our protocol. MDPI 2016-08-23 /pmc/articles/PMC5038621/ /pubmed/27563894 http://dx.doi.org/10.3390/s16091342 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Qin, Xiaoli Wang, Linchun Xie, Qingji Sensitive Bioanalysis Based on in-Situ Droplet Anodic Stripping Voltammetric Detection of CdS Quantum Dots Label after Enhanced Cathodic Preconcentration |
title | Sensitive Bioanalysis Based on in-Situ Droplet Anodic Stripping Voltammetric Detection of CdS Quantum Dots Label after Enhanced Cathodic Preconcentration |
title_full | Sensitive Bioanalysis Based on in-Situ Droplet Anodic Stripping Voltammetric Detection of CdS Quantum Dots Label after Enhanced Cathodic Preconcentration |
title_fullStr | Sensitive Bioanalysis Based on in-Situ Droplet Anodic Stripping Voltammetric Detection of CdS Quantum Dots Label after Enhanced Cathodic Preconcentration |
title_full_unstemmed | Sensitive Bioanalysis Based on in-Situ Droplet Anodic Stripping Voltammetric Detection of CdS Quantum Dots Label after Enhanced Cathodic Preconcentration |
title_short | Sensitive Bioanalysis Based on in-Situ Droplet Anodic Stripping Voltammetric Detection of CdS Quantum Dots Label after Enhanced Cathodic Preconcentration |
title_sort | sensitive bioanalysis based on in-situ droplet anodic stripping voltammetric detection of cds quantum dots label after enhanced cathodic preconcentration |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5038621/ https://www.ncbi.nlm.nih.gov/pubmed/27563894 http://dx.doi.org/10.3390/s16091342 |
work_keys_str_mv | AT qinxiaoli sensitivebioanalysisbasedoninsitudropletanodicstrippingvoltammetricdetectionofcdsquantumdotslabelafterenhancedcathodicpreconcentration AT wanglinchun sensitivebioanalysisbasedoninsitudropletanodicstrippingvoltammetricdetectionofcdsquantumdotslabelafterenhancedcathodicpreconcentration AT xieqingji sensitivebioanalysisbasedoninsitudropletanodicstrippingvoltammetricdetectionofcdsquantumdotslabelafterenhancedcathodicpreconcentration |