Cargando…
The Non-Destructive Test of Steel Corrosion in Reinforced Concrete Bridges Using a Micro-Magnetic Sensor
This paper presents a non-destructive test method for steel corrosion in reinforced concrete bridges by using a 3-dimensional digital micro-magnetic sensor to detect and analyze the self-magnetic field leakage from corroded reinforced concrete. The setup of the magnetic scanning device and the measu...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5038717/ https://www.ncbi.nlm.nih.gov/pubmed/27608029 http://dx.doi.org/10.3390/s16091439 |
_version_ | 1782455936607059968 |
---|---|
author | Zhang, Hong Liao, Leng Zhao, Ruiqiang Zhou, Jianting Yang, Mao Xia, Runchuan |
author_facet | Zhang, Hong Liao, Leng Zhao, Ruiqiang Zhou, Jianting Yang, Mao Xia, Runchuan |
author_sort | Zhang, Hong |
collection | PubMed |
description | This paper presents a non-destructive test method for steel corrosion in reinforced concrete bridges by using a 3-dimensional digital micro-magnetic sensor to detect and analyze the self-magnetic field leakage from corroded reinforced concrete. The setup of the magnetic scanning device and the measurement mode of the micro-magnetic sensor are introduced. The numerical analysis model is also built based on the linear magnetic charge theory. Compared to the self-magnetic field leakage data obtained from magnetic sensor-based measurement and numerical calculation, it is shown that the curves of tangential magnetic field at different lift-off height all intersect near the edge of the steel corrosion zone. The result indicates that the intersection of magnetic field curves can be used to detect and evaluate the range of the inner steel corrosion in engineering structures. The findings of this work propose a new and effective non-destructive test method for steel corrosion, and therefore enlarge the application of the micro-magnetic sensor. |
format | Online Article Text |
id | pubmed-5038717 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-50387172016-09-29 The Non-Destructive Test of Steel Corrosion in Reinforced Concrete Bridges Using a Micro-Magnetic Sensor Zhang, Hong Liao, Leng Zhao, Ruiqiang Zhou, Jianting Yang, Mao Xia, Runchuan Sensors (Basel) Article This paper presents a non-destructive test method for steel corrosion in reinforced concrete bridges by using a 3-dimensional digital micro-magnetic sensor to detect and analyze the self-magnetic field leakage from corroded reinforced concrete. The setup of the magnetic scanning device and the measurement mode of the micro-magnetic sensor are introduced. The numerical analysis model is also built based on the linear magnetic charge theory. Compared to the self-magnetic field leakage data obtained from magnetic sensor-based measurement and numerical calculation, it is shown that the curves of tangential magnetic field at different lift-off height all intersect near the edge of the steel corrosion zone. The result indicates that the intersection of magnetic field curves can be used to detect and evaluate the range of the inner steel corrosion in engineering structures. The findings of this work propose a new and effective non-destructive test method for steel corrosion, and therefore enlarge the application of the micro-magnetic sensor. MDPI 2016-09-06 /pmc/articles/PMC5038717/ /pubmed/27608029 http://dx.doi.org/10.3390/s16091439 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhang, Hong Liao, Leng Zhao, Ruiqiang Zhou, Jianting Yang, Mao Xia, Runchuan The Non-Destructive Test of Steel Corrosion in Reinforced Concrete Bridges Using a Micro-Magnetic Sensor |
title | The Non-Destructive Test of Steel Corrosion in Reinforced Concrete Bridges Using a Micro-Magnetic Sensor |
title_full | The Non-Destructive Test of Steel Corrosion in Reinforced Concrete Bridges Using a Micro-Magnetic Sensor |
title_fullStr | The Non-Destructive Test of Steel Corrosion in Reinforced Concrete Bridges Using a Micro-Magnetic Sensor |
title_full_unstemmed | The Non-Destructive Test of Steel Corrosion in Reinforced Concrete Bridges Using a Micro-Magnetic Sensor |
title_short | The Non-Destructive Test of Steel Corrosion in Reinforced Concrete Bridges Using a Micro-Magnetic Sensor |
title_sort | non-destructive test of steel corrosion in reinforced concrete bridges using a micro-magnetic sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5038717/ https://www.ncbi.nlm.nih.gov/pubmed/27608029 http://dx.doi.org/10.3390/s16091439 |
work_keys_str_mv | AT zhanghong thenondestructivetestofsteelcorrosioninreinforcedconcretebridgesusingamicromagneticsensor AT liaoleng thenondestructivetestofsteelcorrosioninreinforcedconcretebridgesusingamicromagneticsensor AT zhaoruiqiang thenondestructivetestofsteelcorrosioninreinforcedconcretebridgesusingamicromagneticsensor AT zhoujianting thenondestructivetestofsteelcorrosioninreinforcedconcretebridgesusingamicromagneticsensor AT yangmao thenondestructivetestofsteelcorrosioninreinforcedconcretebridgesusingamicromagneticsensor AT xiarunchuan thenondestructivetestofsteelcorrosioninreinforcedconcretebridgesusingamicromagneticsensor AT zhanghong nondestructivetestofsteelcorrosioninreinforcedconcretebridgesusingamicromagneticsensor AT liaoleng nondestructivetestofsteelcorrosioninreinforcedconcretebridgesusingamicromagneticsensor AT zhaoruiqiang nondestructivetestofsteelcorrosioninreinforcedconcretebridgesusingamicromagneticsensor AT zhoujianting nondestructivetestofsteelcorrosioninreinforcedconcretebridgesusingamicromagneticsensor AT yangmao nondestructivetestofsteelcorrosioninreinforcedconcretebridgesusingamicromagneticsensor AT xiarunchuan nondestructivetestofsteelcorrosioninreinforcedconcretebridgesusingamicromagneticsensor |