Cargando…

Application of a handheld Pressure Application Measurement device for the characterisation of mechanical nociceptive thresholds in intact pig tails

The assessment of nociceptive thresholds is employed in animals and humans to evaluate changes in sensitivity potentially arising from tissue damage. Its application on the intact pig tail might represent a suitable method to assess changes in nociceptive thresholds arising from tail injury, such as...

Descripción completa

Detalles Bibliográficos
Autores principales: Di Giminiani, Pierpaolo, Sandercock, Dale A., Malcolm, Emma M., Leach, Matthew C., Herskin, Mette S., Edwards, Sandra A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5038977/
https://www.ncbi.nlm.nih.gov/pubmed/27422675
http://dx.doi.org/10.1016/j.physbeh.2016.07.006
_version_ 1782455984576266240
author Di Giminiani, Pierpaolo
Sandercock, Dale A.
Malcolm, Emma M.
Leach, Matthew C.
Herskin, Mette S.
Edwards, Sandra A.
author_facet Di Giminiani, Pierpaolo
Sandercock, Dale A.
Malcolm, Emma M.
Leach, Matthew C.
Herskin, Mette S.
Edwards, Sandra A.
author_sort Di Giminiani, Pierpaolo
collection PubMed
description The assessment of nociceptive thresholds is employed in animals and humans to evaluate changes in sensitivity potentially arising from tissue damage. Its application on the intact pig tail might represent a suitable method to assess changes in nociceptive thresholds arising from tail injury, such as tail docking or tail biting. The Pressure Application Measurement (PAM) device is used here for the first time on the tail of pigs to determine the reliability of the methods and to provide novel data on mechanical nociceptive thresholds (MNT) associated with four different age groups (9, 17, 24 and 32 weeks) and with proximity of the target region to the body of the animal. We recorded an overall acceptable level of intra-individual reliability, with mean values of CV ranging between 30.1 and 32.6%. Across all age groups, the first single measurement of MNT recorded at region 1 (proximal) was significantly higher (P < 0.05) than the following two. This was not observed at tail regions 2 and 3 (more distal). Age had a significant effect (P < 0.05) on the mean thresholds of nociception with increasing age corresponding to higher thresholds. Furthermore, a significant effect of proximity of tail region to the body was observed (P < 0.05), with MNT being higher in the proximal tail region in pigs of 9, 17 and 24 weeks of age. There was also a significant positive correlation (P < 0.05) between mechanical nociceptive thresholds and age/body size of the animals. To the best of our knowledge, no other investigation of tail nociceptive thresholds has been performed with the PAM device or alternative methods to obtain mechanical nociceptive thresholds in intact tails of pigs of different age/body size. The reliability of the data obtained with the PAM device support its use in the measurement of mechanical nociceptive threshold in pig tails. This methodological approach is possibly suitable for assessing changes in tail stump MNTs after tail injury caused by tail docking and biting.
format Online
Article
Text
id pubmed-5038977
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier Science
record_format MEDLINE/PubMed
spelling pubmed-50389772016-10-15 Application of a handheld Pressure Application Measurement device for the characterisation of mechanical nociceptive thresholds in intact pig tails Di Giminiani, Pierpaolo Sandercock, Dale A. Malcolm, Emma M. Leach, Matthew C. Herskin, Mette S. Edwards, Sandra A. Physiol Behav Article The assessment of nociceptive thresholds is employed in animals and humans to evaluate changes in sensitivity potentially arising from tissue damage. Its application on the intact pig tail might represent a suitable method to assess changes in nociceptive thresholds arising from tail injury, such as tail docking or tail biting. The Pressure Application Measurement (PAM) device is used here for the first time on the tail of pigs to determine the reliability of the methods and to provide novel data on mechanical nociceptive thresholds (MNT) associated with four different age groups (9, 17, 24 and 32 weeks) and with proximity of the target region to the body of the animal. We recorded an overall acceptable level of intra-individual reliability, with mean values of CV ranging between 30.1 and 32.6%. Across all age groups, the first single measurement of MNT recorded at region 1 (proximal) was significantly higher (P < 0.05) than the following two. This was not observed at tail regions 2 and 3 (more distal). Age had a significant effect (P < 0.05) on the mean thresholds of nociception with increasing age corresponding to higher thresholds. Furthermore, a significant effect of proximity of tail region to the body was observed (P < 0.05), with MNT being higher in the proximal tail region in pigs of 9, 17 and 24 weeks of age. There was also a significant positive correlation (P < 0.05) between mechanical nociceptive thresholds and age/body size of the animals. To the best of our knowledge, no other investigation of tail nociceptive thresholds has been performed with the PAM device or alternative methods to obtain mechanical nociceptive thresholds in intact tails of pigs of different age/body size. The reliability of the data obtained with the PAM device support its use in the measurement of mechanical nociceptive threshold in pig tails. This methodological approach is possibly suitable for assessing changes in tail stump MNTs after tail injury caused by tail docking and biting. Elsevier Science 2016-10-15 /pmc/articles/PMC5038977/ /pubmed/27422675 http://dx.doi.org/10.1016/j.physbeh.2016.07.006 Text en © 2016 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Di Giminiani, Pierpaolo
Sandercock, Dale A.
Malcolm, Emma M.
Leach, Matthew C.
Herskin, Mette S.
Edwards, Sandra A.
Application of a handheld Pressure Application Measurement device for the characterisation of mechanical nociceptive thresholds in intact pig tails
title Application of a handheld Pressure Application Measurement device for the characterisation of mechanical nociceptive thresholds in intact pig tails
title_full Application of a handheld Pressure Application Measurement device for the characterisation of mechanical nociceptive thresholds in intact pig tails
title_fullStr Application of a handheld Pressure Application Measurement device for the characterisation of mechanical nociceptive thresholds in intact pig tails
title_full_unstemmed Application of a handheld Pressure Application Measurement device for the characterisation of mechanical nociceptive thresholds in intact pig tails
title_short Application of a handheld Pressure Application Measurement device for the characterisation of mechanical nociceptive thresholds in intact pig tails
title_sort application of a handheld pressure application measurement device for the characterisation of mechanical nociceptive thresholds in intact pig tails
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5038977/
https://www.ncbi.nlm.nih.gov/pubmed/27422675
http://dx.doi.org/10.1016/j.physbeh.2016.07.006
work_keys_str_mv AT digiminianipierpaolo applicationofahandheldpressureapplicationmeasurementdeviceforthecharacterisationofmechanicalnociceptivethresholdsinintactpigtails
AT sandercockdalea applicationofahandheldpressureapplicationmeasurementdeviceforthecharacterisationofmechanicalnociceptivethresholdsinintactpigtails
AT malcolmemmam applicationofahandheldpressureapplicationmeasurementdeviceforthecharacterisationofmechanicalnociceptivethresholdsinintactpigtails
AT leachmatthewc applicationofahandheldpressureapplicationmeasurementdeviceforthecharacterisationofmechanicalnociceptivethresholdsinintactpigtails
AT herskinmettes applicationofahandheldpressureapplicationmeasurementdeviceforthecharacterisationofmechanicalnociceptivethresholdsinintactpigtails
AT edwardssandraa applicationofahandheldpressureapplicationmeasurementdeviceforthecharacterisationofmechanicalnociceptivethresholdsinintactpigtails