Cargando…

Biochip for the Detection of Bacillus anthracis Lethal Factor and Therapeutic Agents against Anthrax Toxins

Tethered lipid bilayer membranes (tBLMs) have been used in many applications, including biosensing and membrane protein structure studies. This report describes a biosensor for anthrax toxins that was fabricated through the self-assembly of a tBLM with B. anthracis protective antigen ion channels th...

Descripción completa

Detalles Bibliográficos
Autores principales: Silin, Vitalii, Kasianowicz, John J., Michelman-Ribeiro, Ariel, Panchal, Rekha G., Bavari, Sina, Robertson, Joseph W. F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5041027/
https://www.ncbi.nlm.nih.gov/pubmed/27348008
http://dx.doi.org/10.3390/membranes6030036
_version_ 1782456328539602944
author Silin, Vitalii
Kasianowicz, John J.
Michelman-Ribeiro, Ariel
Panchal, Rekha G.
Bavari, Sina
Robertson, Joseph W. F.
author_facet Silin, Vitalii
Kasianowicz, John J.
Michelman-Ribeiro, Ariel
Panchal, Rekha G.
Bavari, Sina
Robertson, Joseph W. F.
author_sort Silin, Vitalii
collection PubMed
description Tethered lipid bilayer membranes (tBLMs) have been used in many applications, including biosensing and membrane protein structure studies. This report describes a biosensor for anthrax toxins that was fabricated through the self-assembly of a tBLM with B. anthracis protective antigen ion channels that are both the recognition element and electrochemical transducer. We characterize the sensor and its properties with electrochemical impedance spectroscopy and surface plasmon resonance. The sensor shows a sensitivity similar to ELISA and can also be used to rapidly screen for molecules that bind to the toxins and potentially inhibit their lethal effects.
format Online
Article
Text
id pubmed-5041027
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-50410272016-10-05 Biochip for the Detection of Bacillus anthracis Lethal Factor and Therapeutic Agents against Anthrax Toxins Silin, Vitalii Kasianowicz, John J. Michelman-Ribeiro, Ariel Panchal, Rekha G. Bavari, Sina Robertson, Joseph W. F. Membranes (Basel) Article Tethered lipid bilayer membranes (tBLMs) have been used in many applications, including biosensing and membrane protein structure studies. This report describes a biosensor for anthrax toxins that was fabricated through the self-assembly of a tBLM with B. anthracis protective antigen ion channels that are both the recognition element and electrochemical transducer. We characterize the sensor and its properties with electrochemical impedance spectroscopy and surface plasmon resonance. The sensor shows a sensitivity similar to ELISA and can also be used to rapidly screen for molecules that bind to the toxins and potentially inhibit their lethal effects. MDPI 2016-06-24 /pmc/articles/PMC5041027/ /pubmed/27348008 http://dx.doi.org/10.3390/membranes6030036 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Silin, Vitalii
Kasianowicz, John J.
Michelman-Ribeiro, Ariel
Panchal, Rekha G.
Bavari, Sina
Robertson, Joseph W. F.
Biochip for the Detection of Bacillus anthracis Lethal Factor and Therapeutic Agents against Anthrax Toxins
title Biochip for the Detection of Bacillus anthracis Lethal Factor and Therapeutic Agents against Anthrax Toxins
title_full Biochip for the Detection of Bacillus anthracis Lethal Factor and Therapeutic Agents against Anthrax Toxins
title_fullStr Biochip for the Detection of Bacillus anthracis Lethal Factor and Therapeutic Agents against Anthrax Toxins
title_full_unstemmed Biochip for the Detection of Bacillus anthracis Lethal Factor and Therapeutic Agents against Anthrax Toxins
title_short Biochip for the Detection of Bacillus anthracis Lethal Factor and Therapeutic Agents against Anthrax Toxins
title_sort biochip for the detection of bacillus anthracis lethal factor and therapeutic agents against anthrax toxins
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5041027/
https://www.ncbi.nlm.nih.gov/pubmed/27348008
http://dx.doi.org/10.3390/membranes6030036
work_keys_str_mv AT silinvitalii biochipforthedetectionofbacillusanthracislethalfactorandtherapeuticagentsagainstanthraxtoxins
AT kasianowiczjohnj biochipforthedetectionofbacillusanthracislethalfactorandtherapeuticagentsagainstanthraxtoxins
AT michelmanribeiroariel biochipforthedetectionofbacillusanthracislethalfactorandtherapeuticagentsagainstanthraxtoxins
AT panchalrekhag biochipforthedetectionofbacillusanthracislethalfactorandtherapeuticagentsagainstanthraxtoxins
AT bavarisina biochipforthedetectionofbacillusanthracislethalfactorandtherapeuticagentsagainstanthraxtoxins
AT robertsonjosephwf biochipforthedetectionofbacillusanthracislethalfactorandtherapeuticagentsagainstanthraxtoxins