Automated Versus Manual Blood Pressure Measurement: A Randomized Crossover Trial in the Emergency Department of a Tertiary Care Hospital in Karachi, Pakistan: Are Third World Countries Ready for the Change?

BACKGROUND: Hypertension has proven to be a strong liability with 13.5% of all mortality worldwide being attributed to elevated blood pressures in 2001. An accurate blood pressure measurement lies at the crux of an appropriate diagnosis. Despite the mercury sphygmomanometer being the gold standard,...

Descripción completa

Detalles Bibliográficos
Autores principales: Mansoor, Kanaan, Shahnawaz, Saba, Rasool, Mariam, Chaudhry, Huwad, Ahuja, Gul, Shahnawaz, Sara
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Institute of Immunobiology and Human Genetics 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5042623/
https://www.ncbi.nlm.nih.gov/pubmed/27703563
http://dx.doi.org/10.3889/oamjms.2016.076
_version_ 1782456626079334400
author Mansoor, Kanaan
Shahnawaz, Saba
Rasool, Mariam
Chaudhry, Huwad
Ahuja, Gul
Shahnawaz, Sara
author_facet Mansoor, Kanaan
Shahnawaz, Saba
Rasool, Mariam
Chaudhry, Huwad
Ahuja, Gul
Shahnawaz, Sara
author_sort Mansoor, Kanaan
collection PubMed
description BACKGROUND: Hypertension has proven to be a strong liability with 13.5% of all mortality worldwide being attributed to elevated blood pressures in 2001. An accurate blood pressure measurement lies at the crux of an appropriate diagnosis. Despite the mercury sphygmomanometer being the gold standard, the ongoing deliberation as to whether mercury sphygmomanometers should be replaced with the automated oscillometric devices stems from the risk mercury poses to the environment. AIM: This study was performed to check the validity of automated oscillometric blood pressure measurements as compared to the manual blood pressure measurements in Karachi, Pakistan. MATERIAL AND METHODS: Blood pressure was recorded in 200 individuals aged 15 and above using both, an automated oscillometric blood pressure device (Dinamap Procare 100) and a manual mercury sphygmomanometer concomitantly. Two nurses were assigned to each patient and the device, arm for taking the reading and nurses were randomly determined. SPSS version 20 was used for analysis. Mean and standard deviation of the systolic and diastolic measurements from each modality were compared to each other and P values of 0.05 or less were considered to be significant. Validation criteria of British Hypertension Society (BHS) and the US Association for the Advancement of Medical Instrumentation (AAMI) were used. RESULTS: Two hundred patients were included. The mean of the difference of systolic was 8.54 ± 9.38 while the mean of the difference of diastolic was 4.21 ± 7.88. Patients were further divided into three groups of different systolic blood pressure <= 120, > 120 to = 150 and > 150, their means were 6.27 ± 8.39 (p-value 0.175), 8.91 ± 8.96 (p-value 0.004) and 10.98 ± 10.49 (p-value 0.001) respectively. In our study 89 patients were previously diagnosed with hypertension; their difference of mean systolic was 9.43 ± 9.89 (p-value 0.000) and difference of mean diastolic was 4.26 ± 7.35 (p-value 0.000). CONCLUSIONS: Systolic readings from a previously validated device are not reliable when used in the ER and they show a higher degree of incongruency and inaccuracy when they are used outside validation settings. Also, readings from the right arm tend to be more precise.
format Online
Article
Text
id pubmed-5042623
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Institute of Immunobiology and Human Genetics
record_format MEDLINE/PubMed
spelling pubmed-50426232016-10-04 Automated Versus Manual Blood Pressure Measurement: A Randomized Crossover Trial in the Emergency Department of a Tertiary Care Hospital in Karachi, Pakistan: Are Third World Countries Ready for the Change? Mansoor, Kanaan Shahnawaz, Saba Rasool, Mariam Chaudhry, Huwad Ahuja, Gul Shahnawaz, Sara Open Access Maced J Med Sci Clinical Science BACKGROUND: Hypertension has proven to be a strong liability with 13.5% of all mortality worldwide being attributed to elevated blood pressures in 2001. An accurate blood pressure measurement lies at the crux of an appropriate diagnosis. Despite the mercury sphygmomanometer being the gold standard, the ongoing deliberation as to whether mercury sphygmomanometers should be replaced with the automated oscillometric devices stems from the risk mercury poses to the environment. AIM: This study was performed to check the validity of automated oscillometric blood pressure measurements as compared to the manual blood pressure measurements in Karachi, Pakistan. MATERIAL AND METHODS: Blood pressure was recorded in 200 individuals aged 15 and above using both, an automated oscillometric blood pressure device (Dinamap Procare 100) and a manual mercury sphygmomanometer concomitantly. Two nurses were assigned to each patient and the device, arm for taking the reading and nurses were randomly determined. SPSS version 20 was used for analysis. Mean and standard deviation of the systolic and diastolic measurements from each modality were compared to each other and P values of 0.05 or less were considered to be significant. Validation criteria of British Hypertension Society (BHS) and the US Association for the Advancement of Medical Instrumentation (AAMI) were used. RESULTS: Two hundred patients were included. The mean of the difference of systolic was 8.54 ± 9.38 while the mean of the difference of diastolic was 4.21 ± 7.88. Patients were further divided into three groups of different systolic blood pressure <= 120, > 120 to = 150 and > 150, their means were 6.27 ± 8.39 (p-value 0.175), 8.91 ± 8.96 (p-value 0.004) and 10.98 ± 10.49 (p-value 0.001) respectively. In our study 89 patients were previously diagnosed with hypertension; their difference of mean systolic was 9.43 ± 9.89 (p-value 0.000) and difference of mean diastolic was 4.26 ± 7.35 (p-value 0.000). CONCLUSIONS: Systolic readings from a previously validated device are not reliable when used in the ER and they show a higher degree of incongruency and inaccuracy when they are used outside validation settings. Also, readings from the right arm tend to be more precise. Institute of Immunobiology and Human Genetics 2016-09-15 2016-07-27 /pmc/articles/PMC5042623/ /pubmed/27703563 http://dx.doi.org/10.3889/oamjms.2016.076 Text en Copyright: © 2016 Kanaan Mansoor, Saba Shahnawaz, Mariam Rasool, Huwad Chaudhry, Gul Ahuja, Sara Shahnawaz. http://creativecommons.org/licenses/by/2.5/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Clinical Science
Mansoor, Kanaan
Shahnawaz, Saba
Rasool, Mariam
Chaudhry, Huwad
Ahuja, Gul
Shahnawaz, Sara
Automated Versus Manual Blood Pressure Measurement: A Randomized Crossover Trial in the Emergency Department of a Tertiary Care Hospital in Karachi, Pakistan: Are Third World Countries Ready for the Change?
title Automated Versus Manual Blood Pressure Measurement: A Randomized Crossover Trial in the Emergency Department of a Tertiary Care Hospital in Karachi, Pakistan: Are Third World Countries Ready for the Change?
title_full Automated Versus Manual Blood Pressure Measurement: A Randomized Crossover Trial in the Emergency Department of a Tertiary Care Hospital in Karachi, Pakistan: Are Third World Countries Ready for the Change?
title_fullStr Automated Versus Manual Blood Pressure Measurement: A Randomized Crossover Trial in the Emergency Department of a Tertiary Care Hospital in Karachi, Pakistan: Are Third World Countries Ready for the Change?
title_full_unstemmed Automated Versus Manual Blood Pressure Measurement: A Randomized Crossover Trial in the Emergency Department of a Tertiary Care Hospital in Karachi, Pakistan: Are Third World Countries Ready for the Change?
title_short Automated Versus Manual Blood Pressure Measurement: A Randomized Crossover Trial in the Emergency Department of a Tertiary Care Hospital in Karachi, Pakistan: Are Third World Countries Ready for the Change?
title_sort automated versus manual blood pressure measurement: a randomized crossover trial in the emergency department of a tertiary care hospital in karachi, pakistan: are third world countries ready for the change?
topic Clinical Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5042623/
https://www.ncbi.nlm.nih.gov/pubmed/27703563
http://dx.doi.org/10.3889/oamjms.2016.076
work_keys_str_mv AT mansoorkanaan automatedversusmanualbloodpressuremeasurementarandomizedcrossovertrialintheemergencydepartmentofatertiarycarehospitalinkarachipakistanarethirdworldcountriesreadyforthechange
AT shahnawazsaba automatedversusmanualbloodpressuremeasurementarandomizedcrossovertrialintheemergencydepartmentofatertiarycarehospitalinkarachipakistanarethirdworldcountriesreadyforthechange
AT rasoolmariam automatedversusmanualbloodpressuremeasurementarandomizedcrossovertrialintheemergencydepartmentofatertiarycarehospitalinkarachipakistanarethirdworldcountriesreadyforthechange
AT chaudhryhuwad automatedversusmanualbloodpressuremeasurementarandomizedcrossovertrialintheemergencydepartmentofatertiarycarehospitalinkarachipakistanarethirdworldcountriesreadyforthechange
AT ahujagul automatedversusmanualbloodpressuremeasurementarandomizedcrossovertrialintheemergencydepartmentofatertiarycarehospitalinkarachipakistanarethirdworldcountriesreadyforthechange
AT shahnawazsara automatedversusmanualbloodpressuremeasurementarandomizedcrossovertrialintheemergencydepartmentofatertiarycarehospitalinkarachipakistanarethirdworldcountriesreadyforthechange