Cargando…

Migration of an intrauterine device to the left inguinal region, the first reported case

INTRODUCTION: A large number of complications are reported with the use of IUD. Migration to inguinal region has not been mentioned in literature. We report a rare case of migrated IUD to inguinal canal. CASE REPORT: A 25-year-old lady presented with a painfull mass in the left inguinal region. Diag...

Descripción completa

Detalles Bibliográficos
Autores principales: Aghaways, Ismaeel, Anwer Wahid, Saman, Ali, Rawa Hama Ghareeb, Sabir, Falah, Kakamad, Fahmi Hussein
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5043400/
https://www.ncbi.nlm.nih.gov/pubmed/27689521
http://dx.doi.org/10.1016/j.ijscr.2016.09.030
Descripción
Sumario:INTRODUCTION: A large number of complications are reported with the use of IUD. Migration to inguinal region has not been mentioned in literature. We report a rare case of migrated IUD to inguinal canal. CASE REPORT: A 25-year-old lady presented with a painfull mass in the left inguinal region. Diagnostic work up showed migrated IUD to inguinal region. Operation was done and the impacted IUD with surrounding granuloma was retrieved. DISCUSSION: When the string of the IUD is no longer visible at the external os of the cervix, radiological scan must be performed, this should begin with a sonographic examination and plain abdominal radiography may be used to localize the IUD. CONCLUSION: IUD Migration may occur to unusual area and perforation can be misdiagnosed as non-witnessed expulsion.