A retrospective study to validate an intraoperative robotic classification system for assessing the accuracy of kirschner wire (K-wire) placements with postoperative computed tomography classification system for assessing the accuracy of pedicle screw placements

This purpose of this retrospective study is validation of an intraoperative robotic grading classification system for assessing the accuracy of Kirschner-wire (K-wire) placements with the postoperative computed tomography (CT)-base classification system for assessing the accuracy of pedicle screw pl...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsai, Tai-Hsin, Wu, Dong-Syuan, Su, Yu-Feng, Wu, Chieh-Hsin, Lin, Chih-Lung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5044894/
https://www.ncbi.nlm.nih.gov/pubmed/27661024
http://dx.doi.org/10.1097/MD.0000000000004834
_version_ 1782457013636169728
author Tsai, Tai-Hsin
Wu, Dong-Syuan
Su, Yu-Feng
Wu, Chieh-Hsin
Lin, Chih-Lung
author_facet Tsai, Tai-Hsin
Wu, Dong-Syuan
Su, Yu-Feng
Wu, Chieh-Hsin
Lin, Chih-Lung
author_sort Tsai, Tai-Hsin
collection PubMed
description This purpose of this retrospective study is validation of an intraoperative robotic grading classification system for assessing the accuracy of Kirschner-wire (K-wire) placements with the postoperative computed tomography (CT)-base classification system for assessing the accuracy of pedicle screw placements. We conducted a retrospective review of prospectively collected data from 35 consecutive patients who underwent 176 robotic assisted pedicle screws instrumentation at Kaohsiung Medical University Hospital from September 2014 to November 2015. During the operation, we used a robotic grading classification system for verifying the intraoperative accuracy of K-wire placements. Three months after surgery, we used the common CT-base classification system to assess the postoperative accuracy of pedicle screw placements. The distributions of accuracy between the intraoperative robot-assisted and various postoperative CT-based classification systems were compared using kappa statistics of agreement. The intraoperative accuracies of K-wire placements before and after repositioning were classified as excellent (131/176, 74.4% and 133/176, 75.6%, respectively), satisfactory (36/176, 20.5% and 41/176, 23.3%, respectively), and malpositioned (9/176, 5.1% and 2/176, 1.1%, respectively) In postoperative CT-base classification systems were evaluated. No screw placements were evaluated as unacceptable under any of these systems. Kappa statistics revealed no significant differences between the proposed system and the aforementioned classification systems (P <0.001). Our results revealed no significant differences between the intraoperative robotic grading system and various postoperative CT-based grading systems. The robotic grading classification system is a feasible method for evaluating the accuracy of K-wire placements. Using the intraoperative robot grading system to classify the accuracy of K-wire placements enables predicting the postoperative accuracy of pedicle screw placements.
format Online
Article
Text
id pubmed-5044894
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-50448942016-10-06 A retrospective study to validate an intraoperative robotic classification system for assessing the accuracy of kirschner wire (K-wire) placements with postoperative computed tomography classification system for assessing the accuracy of pedicle screw placements Tsai, Tai-Hsin Wu, Dong-Syuan Su, Yu-Feng Wu, Chieh-Hsin Lin, Chih-Lung Medicine (Baltimore) 7100 This purpose of this retrospective study is validation of an intraoperative robotic grading classification system for assessing the accuracy of Kirschner-wire (K-wire) placements with the postoperative computed tomography (CT)-base classification system for assessing the accuracy of pedicle screw placements. We conducted a retrospective review of prospectively collected data from 35 consecutive patients who underwent 176 robotic assisted pedicle screws instrumentation at Kaohsiung Medical University Hospital from September 2014 to November 2015. During the operation, we used a robotic grading classification system for verifying the intraoperative accuracy of K-wire placements. Three months after surgery, we used the common CT-base classification system to assess the postoperative accuracy of pedicle screw placements. The distributions of accuracy between the intraoperative robot-assisted and various postoperative CT-based classification systems were compared using kappa statistics of agreement. The intraoperative accuracies of K-wire placements before and after repositioning were classified as excellent (131/176, 74.4% and 133/176, 75.6%, respectively), satisfactory (36/176, 20.5% and 41/176, 23.3%, respectively), and malpositioned (9/176, 5.1% and 2/176, 1.1%, respectively) In postoperative CT-base classification systems were evaluated. No screw placements were evaluated as unacceptable under any of these systems. Kappa statistics revealed no significant differences between the proposed system and the aforementioned classification systems (P <0.001). Our results revealed no significant differences between the intraoperative robotic grading system and various postoperative CT-based grading systems. The robotic grading classification system is a feasible method for evaluating the accuracy of K-wire placements. Using the intraoperative robot grading system to classify the accuracy of K-wire placements enables predicting the postoperative accuracy of pedicle screw placements. Wolters Kluwer Health 2016-09-23 /pmc/articles/PMC5044894/ /pubmed/27661024 http://dx.doi.org/10.1097/MD.0000000000004834 Text en Copyright © 2016 the Author(s). Published by Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by/4.0 This is an open access article distributed under the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0
spellingShingle 7100
Tsai, Tai-Hsin
Wu, Dong-Syuan
Su, Yu-Feng
Wu, Chieh-Hsin
Lin, Chih-Lung
A retrospective study to validate an intraoperative robotic classification system for assessing the accuracy of kirschner wire (K-wire) placements with postoperative computed tomography classification system for assessing the accuracy of pedicle screw placements
title A retrospective study to validate an intraoperative robotic classification system for assessing the accuracy of kirschner wire (K-wire) placements with postoperative computed tomography classification system for assessing the accuracy of pedicle screw placements
title_full A retrospective study to validate an intraoperative robotic classification system for assessing the accuracy of kirschner wire (K-wire) placements with postoperative computed tomography classification system for assessing the accuracy of pedicle screw placements
title_fullStr A retrospective study to validate an intraoperative robotic classification system for assessing the accuracy of kirschner wire (K-wire) placements with postoperative computed tomography classification system for assessing the accuracy of pedicle screw placements
title_full_unstemmed A retrospective study to validate an intraoperative robotic classification system for assessing the accuracy of kirschner wire (K-wire) placements with postoperative computed tomography classification system for assessing the accuracy of pedicle screw placements
title_short A retrospective study to validate an intraoperative robotic classification system for assessing the accuracy of kirschner wire (K-wire) placements with postoperative computed tomography classification system for assessing the accuracy of pedicle screw placements
title_sort retrospective study to validate an intraoperative robotic classification system for assessing the accuracy of kirschner wire (k-wire) placements with postoperative computed tomography classification system for assessing the accuracy of pedicle screw placements
topic 7100
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5044894/
https://www.ncbi.nlm.nih.gov/pubmed/27661024
http://dx.doi.org/10.1097/MD.0000000000004834
work_keys_str_mv AT tsaitaihsin aretrospectivestudytovalidateanintraoperativeroboticclassificationsystemforassessingtheaccuracyofkirschnerwirekwireplacementswithpostoperativecomputedtomographyclassificationsystemforassessingtheaccuracyofpediclescrewplacements
AT wudongsyuan aretrospectivestudytovalidateanintraoperativeroboticclassificationsystemforassessingtheaccuracyofkirschnerwirekwireplacementswithpostoperativecomputedtomographyclassificationsystemforassessingtheaccuracyofpediclescrewplacements
AT suyufeng aretrospectivestudytovalidateanintraoperativeroboticclassificationsystemforassessingtheaccuracyofkirschnerwirekwireplacementswithpostoperativecomputedtomographyclassificationsystemforassessingtheaccuracyofpediclescrewplacements
AT wuchiehhsin aretrospectivestudytovalidateanintraoperativeroboticclassificationsystemforassessingtheaccuracyofkirschnerwirekwireplacementswithpostoperativecomputedtomographyclassificationsystemforassessingtheaccuracyofpediclescrewplacements
AT linchihlung aretrospectivestudytovalidateanintraoperativeroboticclassificationsystemforassessingtheaccuracyofkirschnerwirekwireplacementswithpostoperativecomputedtomographyclassificationsystemforassessingtheaccuracyofpediclescrewplacements
AT tsaitaihsin retrospectivestudytovalidateanintraoperativeroboticclassificationsystemforassessingtheaccuracyofkirschnerwirekwireplacementswithpostoperativecomputedtomographyclassificationsystemforassessingtheaccuracyofpediclescrewplacements
AT wudongsyuan retrospectivestudytovalidateanintraoperativeroboticclassificationsystemforassessingtheaccuracyofkirschnerwirekwireplacementswithpostoperativecomputedtomographyclassificationsystemforassessingtheaccuracyofpediclescrewplacements
AT suyufeng retrospectivestudytovalidateanintraoperativeroboticclassificationsystemforassessingtheaccuracyofkirschnerwirekwireplacementswithpostoperativecomputedtomographyclassificationsystemforassessingtheaccuracyofpediclescrewplacements
AT wuchiehhsin retrospectivestudytovalidateanintraoperativeroboticclassificationsystemforassessingtheaccuracyofkirschnerwirekwireplacementswithpostoperativecomputedtomographyclassificationsystemforassessingtheaccuracyofpediclescrewplacements
AT linchihlung retrospectivestudytovalidateanintraoperativeroboticclassificationsystemforassessingtheaccuracyofkirschnerwirekwireplacementswithpostoperativecomputedtomographyclassificationsystemforassessingtheaccuracyofpediclescrewplacements