Cargando…

Validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection

BACKGROUND: Perchlorate salts are relatively stable, soluble in water, and migrate into groundwater sources. Groundwater is an essential source for drinking water suppliers. Perchlorate bears health risks as it is identified to impair normal thyroid function by interfering with iodine uptake by the...

Descripción completa

Detalles Bibliográficos
Autores principales: Seiler, Maike A., Jensen, Detlef, Neist, Udo, Deister, Ursula K., Schmitz, Franz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5044968/
https://www.ncbi.nlm.nih.gov/pubmed/27752451
http://dx.doi.org/10.1186/s12302-016-0086-5
_version_ 1782457030606323712
author Seiler, Maike A.
Jensen, Detlef
Neist, Udo
Deister, Ursula K.
Schmitz, Franz
author_facet Seiler, Maike A.
Jensen, Detlef
Neist, Udo
Deister, Ursula K.
Schmitz, Franz
author_sort Seiler, Maike A.
collection PubMed
description BACKGROUND: Perchlorate salts are relatively stable, soluble in water, and migrate into groundwater sources. Groundwater is an essential source for drinking water suppliers. Perchlorate bears health risks as it is identified to impair normal thyroid function by interfering with iodine uptake by the thyroid gland. The development of a sensitive analytical method for the determination of perchlorate is therefore of the highest interest or public health. Ion chromatography is a sensitive method suitable for perchlorate determinations. This manuscript describes the validation of an ion chromatographic method. Perchlorate is determined by ion chromatography (IC) with conductivity detection after suppression (CD) applying isocratic elution. RESULTS: In this study, the suitability of IC-CD was tested for synthetic samples, selected environmental water, drinking water, and swimming pool water in order to evaluate potential matrix effects on the perchlorate signal even after sample preparation. A sample injection volume of 750 μL was applied to the selected 2-mm-IC column. In untreated samples, the perchlorate peak can be interfered by neighbouring signals from matrix ions like chloride, nitrate, carbonate, and sulphate. Depending on the concentration of the matrix ions, the perchlorate peak can show asymmetric shape in particular when the perchlorate concentration is low. Recovery is reduced with increasing matrix ion concentrations. Dedicated matrix elimination was applied to minimize such effects. A reporting limit of 1.5 μg/L perchlorate and an expanded measurement uncertainty of 13.2 % were achieved. CONCLUSION: The extended method validation proves the applicability of IC based on the EPA 314.0 method for the determination of trace amounts of perchlorate in water samples of different origin. The results support the development of a respective international standard pursued by ISO. The approach evidenced its working robustness and ease of use in terms of eluent preparation, chromatographic resolution, column life time and sample preparation. Due to the simplified analytical workflow of the analytical procedure the application’s integration into the collection of methods of interested laboratories should be facilitated.
format Online
Article
Text
id pubmed-5044968
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-50449682016-10-15 Validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection Seiler, Maike A. Jensen, Detlef Neist, Udo Deister, Ursula K. Schmitz, Franz Environ Sci Eur Research BACKGROUND: Perchlorate salts are relatively stable, soluble in water, and migrate into groundwater sources. Groundwater is an essential source for drinking water suppliers. Perchlorate bears health risks as it is identified to impair normal thyroid function by interfering with iodine uptake by the thyroid gland. The development of a sensitive analytical method for the determination of perchlorate is therefore of the highest interest or public health. Ion chromatography is a sensitive method suitable for perchlorate determinations. This manuscript describes the validation of an ion chromatographic method. Perchlorate is determined by ion chromatography (IC) with conductivity detection after suppression (CD) applying isocratic elution. RESULTS: In this study, the suitability of IC-CD was tested for synthetic samples, selected environmental water, drinking water, and swimming pool water in order to evaluate potential matrix effects on the perchlorate signal even after sample preparation. A sample injection volume of 750 μL was applied to the selected 2-mm-IC column. In untreated samples, the perchlorate peak can be interfered by neighbouring signals from matrix ions like chloride, nitrate, carbonate, and sulphate. Depending on the concentration of the matrix ions, the perchlorate peak can show asymmetric shape in particular when the perchlorate concentration is low. Recovery is reduced with increasing matrix ion concentrations. Dedicated matrix elimination was applied to minimize such effects. A reporting limit of 1.5 μg/L perchlorate and an expanded measurement uncertainty of 13.2 % were achieved. CONCLUSION: The extended method validation proves the applicability of IC based on the EPA 314.0 method for the determination of trace amounts of perchlorate in water samples of different origin. The results support the development of a respective international standard pursued by ISO. The approach evidenced its working robustness and ease of use in terms of eluent preparation, chromatographic resolution, column life time and sample preparation. Due to the simplified analytical workflow of the analytical procedure the application’s integration into the collection of methods of interested laboratories should be facilitated. Springer Berlin Heidelberg 2016-06-07 2016 /pmc/articles/PMC5044968/ /pubmed/27752451 http://dx.doi.org/10.1186/s12302-016-0086-5 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Seiler, Maike A.
Jensen, Detlef
Neist, Udo
Deister, Ursula K.
Schmitz, Franz
Validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection
title Validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection
title_full Validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection
title_fullStr Validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection
title_full_unstemmed Validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection
title_short Validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection
title_sort validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5044968/
https://www.ncbi.nlm.nih.gov/pubmed/27752451
http://dx.doi.org/10.1186/s12302-016-0086-5
work_keys_str_mv AT seilermaikea validationdataforthedeterminationofperchlorateinwaterusingionchromatographywithsuppressedconductivitydetection
AT jensendetlef validationdataforthedeterminationofperchlorateinwaterusingionchromatographywithsuppressedconductivitydetection
AT neistudo validationdataforthedeterminationofperchlorateinwaterusingionchromatographywithsuppressedconductivitydetection
AT deisterursulak validationdataforthedeterminationofperchlorateinwaterusingionchromatographywithsuppressedconductivitydetection
AT schmitzfranz validationdataforthedeterminationofperchlorateinwaterusingionchromatographywithsuppressedconductivitydetection