Cargando…

Phase-targeted X-ray diffraction

A powder X-ray diffraction (XRD) method to enhance the signal of a specific crystalline phase within a mixture is presented for the first time. Specificity to the targeted phase relies on finding coincidences in the ratios of crystal d spacings and the ratios of elemental characteristic X-ray energi...

Descripción completa

Detalles Bibliográficos
Autor principal: Hansford, G. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5045729/
https://www.ncbi.nlm.nih.gov/pubmed/27738415
http://dx.doi.org/10.1107/S1600576716011936
_version_ 1782457176530354176
author Hansford, G. M.
author_facet Hansford, G. M.
author_sort Hansford, G. M.
collection PubMed
description A powder X-ray diffraction (XRD) method to enhance the signal of a specific crystalline phase within a mixture is presented for the first time. Specificity to the targeted phase relies on finding coincidences in the ratios of crystal d spacings and the ratios of elemental characteristic X-ray energies. Such coincidences can be exploited so that the two crystal planes diffract through the same scattering angle at two different X-ray energies. An energy-resolving detector placed at the appropriate scattering angle will detect a significantly enhanced signal at these energies if the target mineral or phase is present in the sample. When implemented using high scattering angles, for example 2θ > 150°, the method is tolerant to sample morphology and distance on the scale of ∼2 mm. The principle of the method is demonstrated experimentally using Pd Lα(1) and Pd Lβ(1) emission lines to enhance the diffraction signal of quartz. Both a pure quartz powder pellet and an unprepared mudstone rock specimen are used to test and develop the phase-targeted method. The technique is further demonstrated in the sensitive detection of retained austenite in steel samples using a combination of In Lβ(1) and Ti Kβ emission lines. For both these examples it is also shown how the use of an attenuating foil, with an absorption edge close to and above the higher-energy characteristic X-ray line, can serve to isolate to some degree the coincidence signals from other fluorescence and diffraction peaks in the detected spectrum. The phase-targeted XRD technique is suitable for implementation using low-cost off-the-shelf components in a handheld or in-line instrument format.
format Online
Article
Text
id pubmed-5045729
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-50457292016-10-13 Phase-targeted X-ray diffraction Hansford, G. M. J Appl Crystallogr Research Papers A powder X-ray diffraction (XRD) method to enhance the signal of a specific crystalline phase within a mixture is presented for the first time. Specificity to the targeted phase relies on finding coincidences in the ratios of crystal d spacings and the ratios of elemental characteristic X-ray energies. Such coincidences can be exploited so that the two crystal planes diffract through the same scattering angle at two different X-ray energies. An energy-resolving detector placed at the appropriate scattering angle will detect a significantly enhanced signal at these energies if the target mineral or phase is present in the sample. When implemented using high scattering angles, for example 2θ > 150°, the method is tolerant to sample morphology and distance on the scale of ∼2 mm. The principle of the method is demonstrated experimentally using Pd Lα(1) and Pd Lβ(1) emission lines to enhance the diffraction signal of quartz. Both a pure quartz powder pellet and an unprepared mudstone rock specimen are used to test and develop the phase-targeted method. The technique is further demonstrated in the sensitive detection of retained austenite in steel samples using a combination of In Lβ(1) and Ti Kβ emission lines. For both these examples it is also shown how the use of an attenuating foil, with an absorption edge close to and above the higher-energy characteristic X-ray line, can serve to isolate to some degree the coincidence signals from other fluorescence and diffraction peaks in the detected spectrum. The phase-targeted XRD technique is suitable for implementation using low-cost off-the-shelf components in a handheld or in-line instrument format. International Union of Crystallography 2016-09-01 /pmc/articles/PMC5045729/ /pubmed/27738415 http://dx.doi.org/10.1107/S1600576716011936 Text en © G. M. Hansford 2016 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
spellingShingle Research Papers
Hansford, G. M.
Phase-targeted X-ray diffraction
title Phase-targeted X-ray diffraction
title_full Phase-targeted X-ray diffraction
title_fullStr Phase-targeted X-ray diffraction
title_full_unstemmed Phase-targeted X-ray diffraction
title_short Phase-targeted X-ray diffraction
title_sort phase-targeted x-ray diffraction
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5045729/
https://www.ncbi.nlm.nih.gov/pubmed/27738415
http://dx.doi.org/10.1107/S1600576716011936
work_keys_str_mv AT hansfordgm phasetargetedxraydiffraction