Cargando…
Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study
BACKGROUND: Nowadays, mini screws are used in orthodontic tooth movement to obtain maximum or absolute anchorage. They have gained popularity among orthodontists for en masse retraction of anterior teeth after first premolar extraction in maximum anchorage cases. The purpose of this study was to det...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5045917/ https://www.ncbi.nlm.nih.gov/pubmed/27667816 http://dx.doi.org/10.1186/s40510-016-0143-z |
_version_ | 1782457193413476352 |
---|---|
author | Hedayati, Zohreh Shomali, Mehrdad |
author_facet | Hedayati, Zohreh Shomali, Mehrdad |
author_sort | Hedayati, Zohreh |
collection | PubMed |
description | BACKGROUND: Nowadays, mini screws are used in orthodontic tooth movement to obtain maximum or absolute anchorage. They have gained popularity among orthodontists for en masse retraction of anterior teeth after first premolar extraction in maximum anchorage cases. The purpose of this study was to determine the type of anterior tooth movement during the time when force was applied from different mini screw placements to the anterior power arm with various heights. METHODS: A finite element method was used for modeling maxillary teeth and bone structure. Brackets, wire, and hooks were also designed for modeling. Two appropriate positions for mini screw in the mesial and distal of the second premolar were designed as fixed nodes. Forces were applied from the mini screw to four different levels of anterior hook height: 0, 3, 6, and 9 mm. Initial tooth movement in eight different conditions was analyzed and calculated with ANSYS software. RESULTS: Rotation of anterior dentition was decreased with a longer anterior power arm and the mesial placement of the mini screw. Bodily movements occurred with the 9-mm height of the power arm in both mini screw positions. Intrusion or extrusion of the anterior teeth segment depended on the level of the mini screw and the edge of the power arm on the Z axis. CONCLUSIONS: According to the findings of this study, the best control in the sagittal plane during anterior en masse retraction was achieved by mesial placement of the mini screw and the 9-mm height of the anterior power arm. Where control in the vertical plane was concerned, distal placement of the mini screw with the 6-mm power arm height had minimum adverse effect on anterior dentition. |
format | Online Article Text |
id | pubmed-5045917 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-50459172016-10-18 Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study Hedayati, Zohreh Shomali, Mehrdad Prog Orthod Research BACKGROUND: Nowadays, mini screws are used in orthodontic tooth movement to obtain maximum or absolute anchorage. They have gained popularity among orthodontists for en masse retraction of anterior teeth after first premolar extraction in maximum anchorage cases. The purpose of this study was to determine the type of anterior tooth movement during the time when force was applied from different mini screw placements to the anterior power arm with various heights. METHODS: A finite element method was used for modeling maxillary teeth and bone structure. Brackets, wire, and hooks were also designed for modeling. Two appropriate positions for mini screw in the mesial and distal of the second premolar were designed as fixed nodes. Forces were applied from the mini screw to four different levels of anterior hook height: 0, 3, 6, and 9 mm. Initial tooth movement in eight different conditions was analyzed and calculated with ANSYS software. RESULTS: Rotation of anterior dentition was decreased with a longer anterior power arm and the mesial placement of the mini screw. Bodily movements occurred with the 9-mm height of the power arm in both mini screw positions. Intrusion or extrusion of the anterior teeth segment depended on the level of the mini screw and the edge of the power arm on the Z axis. CONCLUSIONS: According to the findings of this study, the best control in the sagittal plane during anterior en masse retraction was achieved by mesial placement of the mini screw and the 9-mm height of the anterior power arm. Where control in the vertical plane was concerned, distal placement of the mini screw with the 6-mm power arm height had minimum adverse effect on anterior dentition. Springer Berlin Heidelberg 2016-10-03 /pmc/articles/PMC5045917/ /pubmed/27667816 http://dx.doi.org/10.1186/s40510-016-0143-z Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Hedayati, Zohreh Shomali, Mehrdad Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study |
title | Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study |
title_full | Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study |
title_fullStr | Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study |
title_full_unstemmed | Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study |
title_short | Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study |
title_sort | maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3d finite element study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5045917/ https://www.ncbi.nlm.nih.gov/pubmed/27667816 http://dx.doi.org/10.1186/s40510-016-0143-z |
work_keys_str_mv | AT hedayatizohreh maxillaryanteriorenmasseretractionusingdifferentanteroposteriorpositionofminiscrewa3dfiniteelementstudy AT shomalimehrdad maxillaryanteriorenmasseretractionusingdifferentanteroposteriorpositionofminiscrewa3dfiniteelementstudy |