Cargando…

Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study

BACKGROUND: Nowadays, mini screws are used in orthodontic tooth movement to obtain maximum or absolute anchorage. They have gained popularity among orthodontists for en masse retraction of anterior teeth after first premolar extraction in maximum anchorage cases. The purpose of this study was to det...

Descripción completa

Detalles Bibliográficos
Autores principales: Hedayati, Zohreh, Shomali, Mehrdad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5045917/
https://www.ncbi.nlm.nih.gov/pubmed/27667816
http://dx.doi.org/10.1186/s40510-016-0143-z
_version_ 1782457193413476352
author Hedayati, Zohreh
Shomali, Mehrdad
author_facet Hedayati, Zohreh
Shomali, Mehrdad
author_sort Hedayati, Zohreh
collection PubMed
description BACKGROUND: Nowadays, mini screws are used in orthodontic tooth movement to obtain maximum or absolute anchorage. They have gained popularity among orthodontists for en masse retraction of anterior teeth after first premolar extraction in maximum anchorage cases. The purpose of this study was to determine the type of anterior tooth movement during the time when force was applied from different mini screw placements to the anterior power arm with various heights. METHODS: A finite element method was used for modeling maxillary teeth and bone structure. Brackets, wire, and hooks were also designed for modeling. Two appropriate positions for mini screw in the mesial and distal of the second premolar were designed as fixed nodes. Forces were applied from the mini screw to four different levels of anterior hook height: 0, 3, 6, and 9 mm. Initial tooth movement in eight different conditions was analyzed and calculated with ANSYS software. RESULTS: Rotation of anterior dentition was decreased with a longer anterior power arm and the mesial placement of the mini screw. Bodily movements occurred with the 9-mm height of the power arm in both mini screw positions. Intrusion or extrusion of the anterior teeth segment depended on the level of the mini screw and the edge of the power arm on the Z axis. CONCLUSIONS: According to the findings of this study, the best control in the sagittal plane during anterior en masse retraction was achieved by mesial placement of the mini screw and the 9-mm height of the anterior power arm. Where control in the vertical plane was concerned, distal placement of the mini screw with the 6-mm power arm height had minimum adverse effect on anterior dentition.
format Online
Article
Text
id pubmed-5045917
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-50459172016-10-18 Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study Hedayati, Zohreh Shomali, Mehrdad Prog Orthod Research BACKGROUND: Nowadays, mini screws are used in orthodontic tooth movement to obtain maximum or absolute anchorage. They have gained popularity among orthodontists for en masse retraction of anterior teeth after first premolar extraction in maximum anchorage cases. The purpose of this study was to determine the type of anterior tooth movement during the time when force was applied from different mini screw placements to the anterior power arm with various heights. METHODS: A finite element method was used for modeling maxillary teeth and bone structure. Brackets, wire, and hooks were also designed for modeling. Two appropriate positions for mini screw in the mesial and distal of the second premolar were designed as fixed nodes. Forces were applied from the mini screw to four different levels of anterior hook height: 0, 3, 6, and 9 mm. Initial tooth movement in eight different conditions was analyzed and calculated with ANSYS software. RESULTS: Rotation of anterior dentition was decreased with a longer anterior power arm and the mesial placement of the mini screw. Bodily movements occurred with the 9-mm height of the power arm in both mini screw positions. Intrusion or extrusion of the anterior teeth segment depended on the level of the mini screw and the edge of the power arm on the Z axis. CONCLUSIONS: According to the findings of this study, the best control in the sagittal plane during anterior en masse retraction was achieved by mesial placement of the mini screw and the 9-mm height of the anterior power arm. Where control in the vertical plane was concerned, distal placement of the mini screw with the 6-mm power arm height had minimum adverse effect on anterior dentition. Springer Berlin Heidelberg 2016-10-03 /pmc/articles/PMC5045917/ /pubmed/27667816 http://dx.doi.org/10.1186/s40510-016-0143-z Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Hedayati, Zohreh
Shomali, Mehrdad
Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study
title Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study
title_full Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study
title_fullStr Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study
title_full_unstemmed Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study
title_short Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study
title_sort maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3d finite element study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5045917/
https://www.ncbi.nlm.nih.gov/pubmed/27667816
http://dx.doi.org/10.1186/s40510-016-0143-z
work_keys_str_mv AT hedayatizohreh maxillaryanteriorenmasseretractionusingdifferentanteroposteriorpositionofminiscrewa3dfiniteelementstudy
AT shomalimehrdad maxillaryanteriorenmasseretractionusingdifferentanteroposteriorpositionofminiscrewa3dfiniteelementstudy