Cargando…

Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices

INTRODUCTION: Some cardiovascular devices are licensed based on limited evidence, potentially exposing patients to devices that are not safe or effective. Research is needed to ascertain if the same is true of other types of medical devices. Knee arthroplasty is a widely-used surgical procedure yet...

Descripción completa

Detalles Bibliográficos
Autores principales: Gagliardi, Anna R., Ducey, Ariel, Lehoux, Pascale, Ross, Sue, Trbovich, Patricia, Easty, Anthony, Bell, Chaim, Takata, Julie, Pabinger, Christof, Urbach, David R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5047591/
https://www.ncbi.nlm.nih.gov/pubmed/27695077
http://dx.doi.org/10.1371/journal.pone.0163032
_version_ 1782457443475783680
author Gagliardi, Anna R.
Ducey, Ariel
Lehoux, Pascale
Ross, Sue
Trbovich, Patricia
Easty, Anthony
Bell, Chaim
Takata, Julie
Pabinger, Christof
Urbach, David R.
author_facet Gagliardi, Anna R.
Ducey, Ariel
Lehoux, Pascale
Ross, Sue
Trbovich, Patricia
Easty, Anthony
Bell, Chaim
Takata, Julie
Pabinger, Christof
Urbach, David R.
author_sort Gagliardi, Anna R.
collection PubMed
description INTRODUCTION: Some cardiovascular devices are licensed based on limited evidence, potentially exposing patients to devices that are not safe or effective. Research is needed to ascertain if the same is true of other types of medical devices. Knee arthroplasty is a widely-used surgical procedure yet implant failures are not uncommon. The purpose of this study was to characterize available evidence on the safety and effectiveness of knee implants. METHODS: A review of primary studies included in health technology assessments (HTA) on total (TKA) and unicompartmental knee arthroplasty (UKA) was conducted. MEDLINE, EMBASE, CINAHL, Cochrane Library and Biotechnology & BioEngineering Abstracts were searched from 2005 to 2014, plus journal tables of contents and 32 HTA web sites. Patients were aged 18 and older who underwent primary TKA or UKA assessed in cohort or randomized controlled studies. Summary statistics were used to report study characteristics. RESULTS: A total of 265 eligible primary studies published between 1986 and 2014 involving 59,217 patients were identified in 10 HTAs (2 low, 7 moderate, 1 high risk of bias). Most evaluated TKA (198, 74.5%). The quality of evidence in primary studies was limited. Most studies were industry-funded (23.8%) or offered no declaration of funding or conflict of interest (44.9%); based on uncontrolled single cohorts (58.5%), enrolled fewer than 100 patients (66.4%), and followed patients for 2 years or less (UKA: single cohort 29.8%, comparative cohort 16.7%, randomized trial 25.0%; TKA: single cohort 25.0%, comparative cohort 31.4%, randomized trial 48.6%). Furthermore, most devices were evaluated in only one study (55.3% TKA implants, 61.1% UKA implants). CONCLUSIONS: Patients, physicians, hospitals and payers rely on poor-quality evidence to support decisions about knee implants. Further research is needed to explore how decisions about the use of devices are currently made, and how the evidence base for device safety and effectiveness can be strengthened.
format Online
Article
Text
id pubmed-5047591
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-50475912016-10-27 Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices Gagliardi, Anna R. Ducey, Ariel Lehoux, Pascale Ross, Sue Trbovich, Patricia Easty, Anthony Bell, Chaim Takata, Julie Pabinger, Christof Urbach, David R. PLoS One Research Article INTRODUCTION: Some cardiovascular devices are licensed based on limited evidence, potentially exposing patients to devices that are not safe or effective. Research is needed to ascertain if the same is true of other types of medical devices. Knee arthroplasty is a widely-used surgical procedure yet implant failures are not uncommon. The purpose of this study was to characterize available evidence on the safety and effectiveness of knee implants. METHODS: A review of primary studies included in health technology assessments (HTA) on total (TKA) and unicompartmental knee arthroplasty (UKA) was conducted. MEDLINE, EMBASE, CINAHL, Cochrane Library and Biotechnology & BioEngineering Abstracts were searched from 2005 to 2014, plus journal tables of contents and 32 HTA web sites. Patients were aged 18 and older who underwent primary TKA or UKA assessed in cohort or randomized controlled studies. Summary statistics were used to report study characteristics. RESULTS: A total of 265 eligible primary studies published between 1986 and 2014 involving 59,217 patients were identified in 10 HTAs (2 low, 7 moderate, 1 high risk of bias). Most evaluated TKA (198, 74.5%). The quality of evidence in primary studies was limited. Most studies were industry-funded (23.8%) or offered no declaration of funding or conflict of interest (44.9%); based on uncontrolled single cohorts (58.5%), enrolled fewer than 100 patients (66.4%), and followed patients for 2 years or less (UKA: single cohort 29.8%, comparative cohort 16.7%, randomized trial 25.0%; TKA: single cohort 25.0%, comparative cohort 31.4%, randomized trial 48.6%). Furthermore, most devices were evaluated in only one study (55.3% TKA implants, 61.1% UKA implants). CONCLUSIONS: Patients, physicians, hospitals and payers rely on poor-quality evidence to support decisions about knee implants. Further research is needed to explore how decisions about the use of devices are currently made, and how the evidence base for device safety and effectiveness can be strengthened. Public Library of Science 2016-10-03 /pmc/articles/PMC5047591/ /pubmed/27695077 http://dx.doi.org/10.1371/journal.pone.0163032 Text en © 2016 Gagliardi et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Gagliardi, Anna R.
Ducey, Ariel
Lehoux, Pascale
Ross, Sue
Trbovich, Patricia
Easty, Anthony
Bell, Chaim
Takata, Julie
Pabinger, Christof
Urbach, David R.
Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices
title Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices
title_full Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices
title_fullStr Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices
title_full_unstemmed Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices
title_short Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices
title_sort meta-review of the quantity and quality of evidence for knee arthroplasty devices
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5047591/
https://www.ncbi.nlm.nih.gov/pubmed/27695077
http://dx.doi.org/10.1371/journal.pone.0163032
work_keys_str_mv AT gagliardiannar metareviewofthequantityandqualityofevidenceforkneearthroplastydevices
AT duceyariel metareviewofthequantityandqualityofevidenceforkneearthroplastydevices
AT lehouxpascale metareviewofthequantityandqualityofevidenceforkneearthroplastydevices
AT rosssue metareviewofthequantityandqualityofevidenceforkneearthroplastydevices
AT trbovichpatricia metareviewofthequantityandqualityofevidenceforkneearthroplastydevices
AT eastyanthony metareviewofthequantityandqualityofevidenceforkneearthroplastydevices
AT bellchaim metareviewofthequantityandqualityofevidenceforkneearthroplastydevices
AT takatajulie metareviewofthequantityandqualityofevidenceforkneearthroplastydevices
AT pabingerchristof metareviewofthequantityandqualityofevidenceforkneearthroplastydevices
AT urbachdavidr metareviewofthequantityandqualityofevidenceforkneearthroplastydevices