Cargando…
Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices
INTRODUCTION: Some cardiovascular devices are licensed based on limited evidence, potentially exposing patients to devices that are not safe or effective. Research is needed to ascertain if the same is true of other types of medical devices. Knee arthroplasty is a widely-used surgical procedure yet...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5047591/ https://www.ncbi.nlm.nih.gov/pubmed/27695077 http://dx.doi.org/10.1371/journal.pone.0163032 |
_version_ | 1782457443475783680 |
---|---|
author | Gagliardi, Anna R. Ducey, Ariel Lehoux, Pascale Ross, Sue Trbovich, Patricia Easty, Anthony Bell, Chaim Takata, Julie Pabinger, Christof Urbach, David R. |
author_facet | Gagliardi, Anna R. Ducey, Ariel Lehoux, Pascale Ross, Sue Trbovich, Patricia Easty, Anthony Bell, Chaim Takata, Julie Pabinger, Christof Urbach, David R. |
author_sort | Gagliardi, Anna R. |
collection | PubMed |
description | INTRODUCTION: Some cardiovascular devices are licensed based on limited evidence, potentially exposing patients to devices that are not safe or effective. Research is needed to ascertain if the same is true of other types of medical devices. Knee arthroplasty is a widely-used surgical procedure yet implant failures are not uncommon. The purpose of this study was to characterize available evidence on the safety and effectiveness of knee implants. METHODS: A review of primary studies included in health technology assessments (HTA) on total (TKA) and unicompartmental knee arthroplasty (UKA) was conducted. MEDLINE, EMBASE, CINAHL, Cochrane Library and Biotechnology & BioEngineering Abstracts were searched from 2005 to 2014, plus journal tables of contents and 32 HTA web sites. Patients were aged 18 and older who underwent primary TKA or UKA assessed in cohort or randomized controlled studies. Summary statistics were used to report study characteristics. RESULTS: A total of 265 eligible primary studies published between 1986 and 2014 involving 59,217 patients were identified in 10 HTAs (2 low, 7 moderate, 1 high risk of bias). Most evaluated TKA (198, 74.5%). The quality of evidence in primary studies was limited. Most studies were industry-funded (23.8%) or offered no declaration of funding or conflict of interest (44.9%); based on uncontrolled single cohorts (58.5%), enrolled fewer than 100 patients (66.4%), and followed patients for 2 years or less (UKA: single cohort 29.8%, comparative cohort 16.7%, randomized trial 25.0%; TKA: single cohort 25.0%, comparative cohort 31.4%, randomized trial 48.6%). Furthermore, most devices were evaluated in only one study (55.3% TKA implants, 61.1% UKA implants). CONCLUSIONS: Patients, physicians, hospitals and payers rely on poor-quality evidence to support decisions about knee implants. Further research is needed to explore how decisions about the use of devices are currently made, and how the evidence base for device safety and effectiveness can be strengthened. |
format | Online Article Text |
id | pubmed-5047591 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-50475912016-10-27 Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices Gagliardi, Anna R. Ducey, Ariel Lehoux, Pascale Ross, Sue Trbovich, Patricia Easty, Anthony Bell, Chaim Takata, Julie Pabinger, Christof Urbach, David R. PLoS One Research Article INTRODUCTION: Some cardiovascular devices are licensed based on limited evidence, potentially exposing patients to devices that are not safe or effective. Research is needed to ascertain if the same is true of other types of medical devices. Knee arthroplasty is a widely-used surgical procedure yet implant failures are not uncommon. The purpose of this study was to characterize available evidence on the safety and effectiveness of knee implants. METHODS: A review of primary studies included in health technology assessments (HTA) on total (TKA) and unicompartmental knee arthroplasty (UKA) was conducted. MEDLINE, EMBASE, CINAHL, Cochrane Library and Biotechnology & BioEngineering Abstracts were searched from 2005 to 2014, plus journal tables of contents and 32 HTA web sites. Patients were aged 18 and older who underwent primary TKA or UKA assessed in cohort or randomized controlled studies. Summary statistics were used to report study characteristics. RESULTS: A total of 265 eligible primary studies published between 1986 and 2014 involving 59,217 patients were identified in 10 HTAs (2 low, 7 moderate, 1 high risk of bias). Most evaluated TKA (198, 74.5%). The quality of evidence in primary studies was limited. Most studies were industry-funded (23.8%) or offered no declaration of funding or conflict of interest (44.9%); based on uncontrolled single cohorts (58.5%), enrolled fewer than 100 patients (66.4%), and followed patients for 2 years or less (UKA: single cohort 29.8%, comparative cohort 16.7%, randomized trial 25.0%; TKA: single cohort 25.0%, comparative cohort 31.4%, randomized trial 48.6%). Furthermore, most devices were evaluated in only one study (55.3% TKA implants, 61.1% UKA implants). CONCLUSIONS: Patients, physicians, hospitals and payers rely on poor-quality evidence to support decisions about knee implants. Further research is needed to explore how decisions about the use of devices are currently made, and how the evidence base for device safety and effectiveness can be strengthened. Public Library of Science 2016-10-03 /pmc/articles/PMC5047591/ /pubmed/27695077 http://dx.doi.org/10.1371/journal.pone.0163032 Text en © 2016 Gagliardi et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Gagliardi, Anna R. Ducey, Ariel Lehoux, Pascale Ross, Sue Trbovich, Patricia Easty, Anthony Bell, Chaim Takata, Julie Pabinger, Christof Urbach, David R. Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices |
title | Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices |
title_full | Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices |
title_fullStr | Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices |
title_full_unstemmed | Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices |
title_short | Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices |
title_sort | meta-review of the quantity and quality of evidence for knee arthroplasty devices |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5047591/ https://www.ncbi.nlm.nih.gov/pubmed/27695077 http://dx.doi.org/10.1371/journal.pone.0163032 |
work_keys_str_mv | AT gagliardiannar metareviewofthequantityandqualityofevidenceforkneearthroplastydevices AT duceyariel metareviewofthequantityandqualityofevidenceforkneearthroplastydevices AT lehouxpascale metareviewofthequantityandqualityofevidenceforkneearthroplastydevices AT rosssue metareviewofthequantityandqualityofevidenceforkneearthroplastydevices AT trbovichpatricia metareviewofthequantityandqualityofevidenceforkneearthroplastydevices AT eastyanthony metareviewofthequantityandqualityofevidenceforkneearthroplastydevices AT bellchaim metareviewofthequantityandqualityofevidenceforkneearthroplastydevices AT takatajulie metareviewofthequantityandqualityofevidenceforkneearthroplastydevices AT pabingerchristof metareviewofthequantityandqualityofevidenceforkneearthroplastydevices AT urbachdavidr metareviewofthequantityandqualityofevidenceforkneearthroplastydevices |