Central venous catheter malposition due to dialysis catheter: a case report
A 56-year-old man on maintenance hemodialysis was admitted to the intensive care unit with septic shock and coagulopathy. As there was a dialysis catheter in the right internal jugular vein, the left internal jugular vein was cannulated with a central venous catheter to initiate vasopressor therapy....
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Anesthesiologists
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5047993/ https://www.ncbi.nlm.nih.gov/pubmed/27703638 http://dx.doi.org/10.4097/kjae.2016.69.5.532 |
_version_ | 1782457514329112576 |
---|---|
author | Rao, Parnandi Bhaskar Singh, Neha Samson, Sumanth |
author_facet | Rao, Parnandi Bhaskar Singh, Neha Samson, Sumanth |
author_sort | Rao, Parnandi Bhaskar |
collection | PubMed |
description | A 56-year-old man on maintenance hemodialysis was admitted to the intensive care unit with septic shock and coagulopathy. As there was a dialysis catheter in the right internal jugular vein, the left internal jugular vein was cannulated with a central venous catheter to initiate vasopressor therapy. A chest X-ray showed formation of a catheter loop inside the left brachiocephalic vein, probably due to hindrance by the dialysis catheter. This report describes the hurdles encountered, repeated cannulation attempts, and serial chest X-ray findings required to obtain acceptable placement of the catheter tip. |
format | Online Article Text |
id | pubmed-5047993 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Korean Society of Anesthesiologists |
record_format | MEDLINE/PubMed |
spelling | pubmed-50479932016-10-04 Central venous catheter malposition due to dialysis catheter: a case report Rao, Parnandi Bhaskar Singh, Neha Samson, Sumanth Korean J Anesthesiol Case Report A 56-year-old man on maintenance hemodialysis was admitted to the intensive care unit with septic shock and coagulopathy. As there was a dialysis catheter in the right internal jugular vein, the left internal jugular vein was cannulated with a central venous catheter to initiate vasopressor therapy. A chest X-ray showed formation of a catheter loop inside the left brachiocephalic vein, probably due to hindrance by the dialysis catheter. This report describes the hurdles encountered, repeated cannulation attempts, and serial chest X-ray findings required to obtain acceptable placement of the catheter tip. The Korean Society of Anesthesiologists 2016-10 2016-08-18 /pmc/articles/PMC5047993/ /pubmed/27703638 http://dx.doi.org/10.4097/kjae.2016.69.5.532 Text en Copyright © the Korean Society of Anesthesiologists, 2016 http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Rao, Parnandi Bhaskar Singh, Neha Samson, Sumanth Central venous catheter malposition due to dialysis catheter: a case report |
title | Central venous catheter malposition due to dialysis catheter: a case report |
title_full | Central venous catheter malposition due to dialysis catheter: a case report |
title_fullStr | Central venous catheter malposition due to dialysis catheter: a case report |
title_full_unstemmed | Central venous catheter malposition due to dialysis catheter: a case report |
title_short | Central venous catheter malposition due to dialysis catheter: a case report |
title_sort | central venous catheter malposition due to dialysis catheter: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5047993/ https://www.ncbi.nlm.nih.gov/pubmed/27703638 http://dx.doi.org/10.4097/kjae.2016.69.5.532 |
work_keys_str_mv | AT raoparnandibhaskar centralvenouscathetermalpositionduetodialysiscatheteracasereport AT singhneha centralvenouscathetermalpositionduetodialysiscatheteracasereport AT samsonsumanth centralvenouscathetermalpositionduetodialysiscatheteracasereport |