Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions

BACKGROUND: Wearable activity monitors such as Fitbit enable users to track various attributes of their physical activity (PA) over time and have the potential to be used in research to promote and measure PA behavior. However, the measurement accuracy of Fitbit in absolute free-living conditions is...

Descripción completa

Detalles Bibliográficos
Autores principales: Dominick, Gregory M, Winfree, Kyle N, Pohlig, Ryan T, Papas, Mia A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5048058/
https://www.ncbi.nlm.nih.gov/pubmed/27644334
http://dx.doi.org/10.2196/mhealth.6281
_version_ 1782457529142345728
author Dominick, Gregory M
Winfree, Kyle N
Pohlig, Ryan T
Papas, Mia A
author_facet Dominick, Gregory M
Winfree, Kyle N
Pohlig, Ryan T
Papas, Mia A
author_sort Dominick, Gregory M
collection PubMed
description BACKGROUND: Wearable activity monitors such as Fitbit enable users to track various attributes of their physical activity (PA) over time and have the potential to be used in research to promote and measure PA behavior. However, the measurement accuracy of Fitbit in absolute free-living conditions is largely unknown. OBJECTIVE: To examine the measurement congruence between Fitbit Flex and ActiGraph GT3X for quantifying steps, metabolic equivalent tasks (METs), and proportion of time in sedentary activity and light-, moderate-, and vigorous-intensity PA in healthy adults in free-living conditions. METHODS: A convenience sample of 19 participants (4 men and 15 women), aged 18-37 years, concurrently wore the Fitbit Flex (wrist) and ActiGraph GT3X (waist) for 1- or 2-week observation periods (n=3 and n=16, respectively) that included self-reported bouts of daily exercise. Data were examined for daily activity, averaged over 14 days and for minutes of reported exercise. Average day-level data included steps, METs, and proportion of time in different intensity levels. Minute-level data included steps, METs, and mean intensity score (0 = sedentary, 3 = vigorous) for overall reported exercise bouts (N=120) and by exercise type (walking, n=16; run or sports, n=44; cardio machine, n=20). RESULTS: Measures of steps were similar between devices for average day- and minute-level observations (all P values > .05). Fitbit significantly overestimated METs for average daily activity, for overall minutes of reported exercise bouts, and for walking and run or sports exercises (mean difference 0.70, 1.80, 3.16, and 2.00 METs, respectively; all P values < .001). For average daily activity, Fitbit significantly underestimated the proportion of time in sedentary and light intensity by 20% and 34%, respectively, and overestimated time by 3% in both moderate and vigorous intensity (all P values < .001). Mean intensity scores were not different for overall minutes of exercise or for run or sports and cardio-machine exercises (all P values > .05). CONCLUSIONS: Fitbit Flex provides accurate measures of steps for daily activity and minutes of reported exercise, regardless of exercise type. Although the proportion of time in different intensity levels varied between devices, examining the mean intensity score for minute-level bouts across different exercise types enabled interdevice comparisons that revealed similar measures of exercise intensity. Fitbit Flex is shown to have measurement limitations that may affect its potential utility and validity for measuring PA attributes in free-living conditions.
format Online
Article
Text
id pubmed-5048058
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-50480582016-10-18 Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions Dominick, Gregory M Winfree, Kyle N Pohlig, Ryan T Papas, Mia A JMIR Mhealth Uhealth Original Paper BACKGROUND: Wearable activity monitors such as Fitbit enable users to track various attributes of their physical activity (PA) over time and have the potential to be used in research to promote and measure PA behavior. However, the measurement accuracy of Fitbit in absolute free-living conditions is largely unknown. OBJECTIVE: To examine the measurement congruence between Fitbit Flex and ActiGraph GT3X for quantifying steps, metabolic equivalent tasks (METs), and proportion of time in sedentary activity and light-, moderate-, and vigorous-intensity PA in healthy adults in free-living conditions. METHODS: A convenience sample of 19 participants (4 men and 15 women), aged 18-37 years, concurrently wore the Fitbit Flex (wrist) and ActiGraph GT3X (waist) for 1- or 2-week observation periods (n=3 and n=16, respectively) that included self-reported bouts of daily exercise. Data were examined for daily activity, averaged over 14 days and for minutes of reported exercise. Average day-level data included steps, METs, and proportion of time in different intensity levels. Minute-level data included steps, METs, and mean intensity score (0 = sedentary, 3 = vigorous) for overall reported exercise bouts (N=120) and by exercise type (walking, n=16; run or sports, n=44; cardio machine, n=20). RESULTS: Measures of steps were similar between devices for average day- and minute-level observations (all P values > .05). Fitbit significantly overestimated METs for average daily activity, for overall minutes of reported exercise bouts, and for walking and run or sports exercises (mean difference 0.70, 1.80, 3.16, and 2.00 METs, respectively; all P values < .001). For average daily activity, Fitbit significantly underestimated the proportion of time in sedentary and light intensity by 20% and 34%, respectively, and overestimated time by 3% in both moderate and vigorous intensity (all P values < .001). Mean intensity scores were not different for overall minutes of exercise or for run or sports and cardio-machine exercises (all P values > .05). CONCLUSIONS: Fitbit Flex provides accurate measures of steps for daily activity and minutes of reported exercise, regardless of exercise type. Although the proportion of time in different intensity levels varied between devices, examining the mean intensity score for minute-level bouts across different exercise types enabled interdevice comparisons that revealed similar measures of exercise intensity. Fitbit Flex is shown to have measurement limitations that may affect its potential utility and validity for measuring PA attributes in free-living conditions. JMIR Publications 2016-09-19 /pmc/articles/PMC5048058/ /pubmed/27644334 http://dx.doi.org/10.2196/mhealth.6281 Text en ©Gregory M Dominick, Kyle N Winfree, Ryan T Pohlig, Mia A Papas. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 19.09.2016. https://creativecommons.org/licenses/by/2.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0/ (https://creativecommons.org/licenses/by/2.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mhealth and uhealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Dominick, Gregory M
Winfree, Kyle N
Pohlig, Ryan T
Papas, Mia A
Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions
title Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions
title_full Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions
title_fullStr Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions
title_full_unstemmed Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions
title_short Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions
title_sort physical activity assessment between consumer- and research-grade accelerometers: a comparative study in free-living conditions
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5048058/
https://www.ncbi.nlm.nih.gov/pubmed/27644334
http://dx.doi.org/10.2196/mhealth.6281
work_keys_str_mv AT dominickgregorym physicalactivityassessmentbetweenconsumerandresearchgradeaccelerometersacomparativestudyinfreelivingconditions
AT winfreekylen physicalactivityassessmentbetweenconsumerandresearchgradeaccelerometersacomparativestudyinfreelivingconditions
AT pohligryant physicalactivityassessmentbetweenconsumerandresearchgradeaccelerometersacomparativestudyinfreelivingconditions
AT papasmiaa physicalactivityassessmentbetweenconsumerandresearchgradeaccelerometersacomparativestudyinfreelivingconditions