Cargando…

Grayscale inversion radiographic view provided improved intra- and inter-observer reliabilities in measuring spinopelvic parameters in asymptomatic adult population

BACKGROUND: Recently, a grayscale inversion view was reported to improve intra- and inter-observer reliabilities in measuring coronal curvature with Cobb and pedicle methods in scoliosis patients. However, the grayscale transformation has never been applied to the measurements of spinopelvic paramet...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Weixiang, Zhou, Jin, Qin, Xiaodong, Xu, Leilei, Yuan, Xinxin, Li, Yang, Qiu, Yong, Zhu, Zezhang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5048461/
https://www.ncbi.nlm.nih.gov/pubmed/27716237
http://dx.doi.org/10.1186/s12891-016-1269-3
_version_ 1782457595679735808
author Sun, Weixiang
Zhou, Jin
Qin, Xiaodong
Xu, Leilei
Yuan, Xinxin
Li, Yang
Qiu, Yong
Zhu, Zezhang
author_facet Sun, Weixiang
Zhou, Jin
Qin, Xiaodong
Xu, Leilei
Yuan, Xinxin
Li, Yang
Qiu, Yong
Zhu, Zezhang
author_sort Sun, Weixiang
collection PubMed
description BACKGROUND: Recently, a grayscale inversion view was reported to improve intra- and inter-observer reliabilities in measuring coronal curvature with Cobb and pedicle methods in scoliosis patients. However, the grayscale transformation has never been applied to the measurements of spinopelvic parameters. The purpose of this study was to compare the measurement reliabilities of the spinoplevic sagittal parameters between the ‘Standard View’ and the ‘Grayscale Inversion View’ in normal adult populations. METHODS: A total of 30 asymptomatic subjects aged between 30 and 40 years were included in this study. Whole-spine posteroanterior radiographs were used to measure the spinoplevic sagittal parameters including thoracic kyphosis (TK), lumbar lordosis (LL), sagittal vertical axis (SVA), pelvic incidence (PI), sacral slope (SS) and pelvic tilt (PT) in both standard view and grayscale inversion view. Two independent observers measured the parameters twice at a 2-week interval. Intra- and inter-observer reliabilities were compared between the two radiographic views. The absolute differences between the two sets of measurements on each view were calculated and compared. RESULTS: The intra-class correlation coefficients (ICCs) of PI, PT and SVA were greater in the grayscale inversion view than in the standard view (0.972 vs 0.817, 0.937 vs 0.833 and 0.964 vs 0.901 for observer 1, respectively; 0.990 vs 0.826, 0.995 vs 0.842 and 0.969 vs 0.919 for observer 2, respectively). Overall, the improvement of ICC was greater in parameters of sagittal pelvic alignment than in those of sagittal spinal alignment. As for the mean absolute differences between two measurements, significant differences existed between the two views in terms of PI, PT and SVA (p = 0.014, 0.016 and 0.011 for observer 1, respectively; p = 0.014, 0.025 and 0.046 for observer 2, respectively). CONCLUSIONS: A grayscale inversion view provided improved intra- and inter-observer reliabilities in measuring spinoplevic alignment when compared with a standard view. This view was more useful in subjects whose pelvic anatomical structures can’t be identified clearly on the standard X-ray view.
format Online
Article
Text
id pubmed-5048461
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-50484612016-10-11 Grayscale inversion radiographic view provided improved intra- and inter-observer reliabilities in measuring spinopelvic parameters in asymptomatic adult population Sun, Weixiang Zhou, Jin Qin, Xiaodong Xu, Leilei Yuan, Xinxin Li, Yang Qiu, Yong Zhu, Zezhang BMC Musculoskelet Disord Research Article BACKGROUND: Recently, a grayscale inversion view was reported to improve intra- and inter-observer reliabilities in measuring coronal curvature with Cobb and pedicle methods in scoliosis patients. However, the grayscale transformation has never been applied to the measurements of spinopelvic parameters. The purpose of this study was to compare the measurement reliabilities of the spinoplevic sagittal parameters between the ‘Standard View’ and the ‘Grayscale Inversion View’ in normal adult populations. METHODS: A total of 30 asymptomatic subjects aged between 30 and 40 years were included in this study. Whole-spine posteroanterior radiographs were used to measure the spinoplevic sagittal parameters including thoracic kyphosis (TK), lumbar lordosis (LL), sagittal vertical axis (SVA), pelvic incidence (PI), sacral slope (SS) and pelvic tilt (PT) in both standard view and grayscale inversion view. Two independent observers measured the parameters twice at a 2-week interval. Intra- and inter-observer reliabilities were compared between the two radiographic views. The absolute differences between the two sets of measurements on each view were calculated and compared. RESULTS: The intra-class correlation coefficients (ICCs) of PI, PT and SVA were greater in the grayscale inversion view than in the standard view (0.972 vs 0.817, 0.937 vs 0.833 and 0.964 vs 0.901 for observer 1, respectively; 0.990 vs 0.826, 0.995 vs 0.842 and 0.969 vs 0.919 for observer 2, respectively). Overall, the improvement of ICC was greater in parameters of sagittal pelvic alignment than in those of sagittal spinal alignment. As for the mean absolute differences between two measurements, significant differences existed between the two views in terms of PI, PT and SVA (p = 0.014, 0.016 and 0.011 for observer 1, respectively; p = 0.014, 0.025 and 0.046 for observer 2, respectively). CONCLUSIONS: A grayscale inversion view provided improved intra- and inter-observer reliabilities in measuring spinoplevic alignment when compared with a standard view. This view was more useful in subjects whose pelvic anatomical structures can’t be identified clearly on the standard X-ray view. BioMed Central 2016-10-03 /pmc/articles/PMC5048461/ /pubmed/27716237 http://dx.doi.org/10.1186/s12891-016-1269-3 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Sun, Weixiang
Zhou, Jin
Qin, Xiaodong
Xu, Leilei
Yuan, Xinxin
Li, Yang
Qiu, Yong
Zhu, Zezhang
Grayscale inversion radiographic view provided improved intra- and inter-observer reliabilities in measuring spinopelvic parameters in asymptomatic adult population
title Grayscale inversion radiographic view provided improved intra- and inter-observer reliabilities in measuring spinopelvic parameters in asymptomatic adult population
title_full Grayscale inversion radiographic view provided improved intra- and inter-observer reliabilities in measuring spinopelvic parameters in asymptomatic adult population
title_fullStr Grayscale inversion radiographic view provided improved intra- and inter-observer reliabilities in measuring spinopelvic parameters in asymptomatic adult population
title_full_unstemmed Grayscale inversion radiographic view provided improved intra- and inter-observer reliabilities in measuring spinopelvic parameters in asymptomatic adult population
title_short Grayscale inversion radiographic view provided improved intra- and inter-observer reliabilities in measuring spinopelvic parameters in asymptomatic adult population
title_sort grayscale inversion radiographic view provided improved intra- and inter-observer reliabilities in measuring spinopelvic parameters in asymptomatic adult population
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5048461/
https://www.ncbi.nlm.nih.gov/pubmed/27716237
http://dx.doi.org/10.1186/s12891-016-1269-3
work_keys_str_mv AT sunweixiang grayscaleinversionradiographicviewprovidedimprovedintraandinterobserverreliabilitiesinmeasuringspinopelvicparametersinasymptomaticadultpopulation
AT zhoujin grayscaleinversionradiographicviewprovidedimprovedintraandinterobserverreliabilitiesinmeasuringspinopelvicparametersinasymptomaticadultpopulation
AT qinxiaodong grayscaleinversionradiographicviewprovidedimprovedintraandinterobserverreliabilitiesinmeasuringspinopelvicparametersinasymptomaticadultpopulation
AT xuleilei grayscaleinversionradiographicviewprovidedimprovedintraandinterobserverreliabilitiesinmeasuringspinopelvicparametersinasymptomaticadultpopulation
AT yuanxinxin grayscaleinversionradiographicviewprovidedimprovedintraandinterobserverreliabilitiesinmeasuringspinopelvicparametersinasymptomaticadultpopulation
AT liyang grayscaleinversionradiographicviewprovidedimprovedintraandinterobserverreliabilitiesinmeasuringspinopelvicparametersinasymptomaticadultpopulation
AT qiuyong grayscaleinversionradiographicviewprovidedimprovedintraandinterobserverreliabilitiesinmeasuringspinopelvicparametersinasymptomaticadultpopulation
AT zhuzezhang grayscaleinversionradiographicviewprovidedimprovedintraandinterobserverreliabilitiesinmeasuringspinopelvicparametersinasymptomaticadultpopulation