Cargando…
Lipiodol retention pattern assessed by cone beam computed tomography during conventional transarterial chemoembolization of hepatocellular carcinoma: accuracy and correlation with response
BACKGROUND: To investigate accuracy of intraprocedural cone beam computed tomography (CBCT) compared to fluoroscopy for detection of lipiodol retention pattern during conventional transarterial chemoembolization (cTACE) of hepatocellular carcinoma (HCC) and its correlation with short-term response....
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5048686/ https://www.ncbi.nlm.nih.gov/pubmed/27716376 http://dx.doi.org/10.1186/s40644-016-0090-4 |
_version_ | 1782457616738287616 |
---|---|
author | Hu, Jungang Maybody, Majid Cao, Guang Wang, Xiao Chen, Hui Zhu, Xu Yang, Renjie Wang, Xiaodong |
author_facet | Hu, Jungang Maybody, Majid Cao, Guang Wang, Xiao Chen, Hui Zhu, Xu Yang, Renjie Wang, Xiaodong |
author_sort | Hu, Jungang |
collection | PubMed |
description | BACKGROUND: To investigate accuracy of intraprocedural cone beam computed tomography (CBCT) compared to fluoroscopy for detection of lipiodol retention pattern during conventional transarterial chemoembolization (cTACE) of hepatocellular carcinoma (HCC) and its correlation with short-term response. METHODS: Between September 2013 and July 2014, 29 patients with HCC underwent chemoembolization of 51 tumors (mean diameter 28.1 mm, range 10.0–136.3 mm). Lipiodol retention pattern was assessed by CBCT at the endpoint of cTACE compared by fluoroscopy. Depending on the pattern of tumor covered by lipiodol three classes were defined: complete (more than 90 %, no peripheral defects), moderate (50–90 %, some with or without peripheral defects), and poor (less than 50 %). Tumor response was assessed by modified Response Evaluation Criteria in Solid Tumors (mRECIST) based on follow-up contrast enhanced (CE) computed tomography (CT) or magnetic resonance imaging (MRI) obtained 4–6 weeks post-cTACE. Correlations between lipiodol retention patterns on CBCT and fluoroscopy as well as tumor response were assessed using multivariate logistic regression. RESULTS: Of 51 hepatic tumors, 40 (78.4 %) had complete response (CR); 8 (15.7 %) had partial response (PR); 1 (2.0 %) had stable disease (SD); and 2 (3.9 %) had progressive disease (PD). The degree of lipiodol retention scored excellent, moderate, and poor, in fluoroscopic images vs CBCT images were 23 (45.1 %) vs 39 (76.5 %), 19 (37.3 %) vs 11 (21.6 %), and 9 (17.6 %) vs 1 (2.0 %), respectively. Lipiodol retention assessment with CBCT (A(z) = 0.75) is more accurate than fluoroscopy (A(z) = 0.54) in predicting target tumor response. Other than lipiodol retention pattern assessed with CBCT (p = 0.01), tumor size (p = 0.04) is an independent predictors of CR. CONCLUSION: CBCT is more accurate than fluoroscopy in classification of lipiodol retention pattern in HCC tumors at the time of cTACE. CBCT could be used as a reliable intra precedural monitoring modality of cTACE. |
format | Online Article Text |
id | pubmed-5048686 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-50486862016-10-12 Lipiodol retention pattern assessed by cone beam computed tomography during conventional transarterial chemoembolization of hepatocellular carcinoma: accuracy and correlation with response Hu, Jungang Maybody, Majid Cao, Guang Wang, Xiao Chen, Hui Zhu, Xu Yang, Renjie Wang, Xiaodong Cancer Imaging Research Article BACKGROUND: To investigate accuracy of intraprocedural cone beam computed tomography (CBCT) compared to fluoroscopy for detection of lipiodol retention pattern during conventional transarterial chemoembolization (cTACE) of hepatocellular carcinoma (HCC) and its correlation with short-term response. METHODS: Between September 2013 and July 2014, 29 patients with HCC underwent chemoembolization of 51 tumors (mean diameter 28.1 mm, range 10.0–136.3 mm). Lipiodol retention pattern was assessed by CBCT at the endpoint of cTACE compared by fluoroscopy. Depending on the pattern of tumor covered by lipiodol three classes were defined: complete (more than 90 %, no peripheral defects), moderate (50–90 %, some with or without peripheral defects), and poor (less than 50 %). Tumor response was assessed by modified Response Evaluation Criteria in Solid Tumors (mRECIST) based on follow-up contrast enhanced (CE) computed tomography (CT) or magnetic resonance imaging (MRI) obtained 4–6 weeks post-cTACE. Correlations between lipiodol retention patterns on CBCT and fluoroscopy as well as tumor response were assessed using multivariate logistic regression. RESULTS: Of 51 hepatic tumors, 40 (78.4 %) had complete response (CR); 8 (15.7 %) had partial response (PR); 1 (2.0 %) had stable disease (SD); and 2 (3.9 %) had progressive disease (PD). The degree of lipiodol retention scored excellent, moderate, and poor, in fluoroscopic images vs CBCT images were 23 (45.1 %) vs 39 (76.5 %), 19 (37.3 %) vs 11 (21.6 %), and 9 (17.6 %) vs 1 (2.0 %), respectively. Lipiodol retention assessment with CBCT (A(z) = 0.75) is more accurate than fluoroscopy (A(z) = 0.54) in predicting target tumor response. Other than lipiodol retention pattern assessed with CBCT (p = 0.01), tumor size (p = 0.04) is an independent predictors of CR. CONCLUSION: CBCT is more accurate than fluoroscopy in classification of lipiodol retention pattern in HCC tumors at the time of cTACE. CBCT could be used as a reliable intra precedural monitoring modality of cTACE. BioMed Central 2016-10-03 /pmc/articles/PMC5048686/ /pubmed/27716376 http://dx.doi.org/10.1186/s40644-016-0090-4 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Hu, Jungang Maybody, Majid Cao, Guang Wang, Xiao Chen, Hui Zhu, Xu Yang, Renjie Wang, Xiaodong Lipiodol retention pattern assessed by cone beam computed tomography during conventional transarterial chemoembolization of hepatocellular carcinoma: accuracy and correlation with response |
title | Lipiodol retention pattern assessed by cone beam computed tomography during conventional transarterial chemoembolization of hepatocellular carcinoma: accuracy and correlation with response |
title_full | Lipiodol retention pattern assessed by cone beam computed tomography during conventional transarterial chemoembolization of hepatocellular carcinoma: accuracy and correlation with response |
title_fullStr | Lipiodol retention pattern assessed by cone beam computed tomography during conventional transarterial chemoembolization of hepatocellular carcinoma: accuracy and correlation with response |
title_full_unstemmed | Lipiodol retention pattern assessed by cone beam computed tomography during conventional transarterial chemoembolization of hepatocellular carcinoma: accuracy and correlation with response |
title_short | Lipiodol retention pattern assessed by cone beam computed tomography during conventional transarterial chemoembolization of hepatocellular carcinoma: accuracy and correlation with response |
title_sort | lipiodol retention pattern assessed by cone beam computed tomography during conventional transarterial chemoembolization of hepatocellular carcinoma: accuracy and correlation with response |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5048686/ https://www.ncbi.nlm.nih.gov/pubmed/27716376 http://dx.doi.org/10.1186/s40644-016-0090-4 |
work_keys_str_mv | AT hujungang lipiodolretentionpatternassessedbyconebeamcomputedtomographyduringconventionaltransarterialchemoembolizationofhepatocellularcarcinomaaccuracyandcorrelationwithresponse AT maybodymajid lipiodolretentionpatternassessedbyconebeamcomputedtomographyduringconventionaltransarterialchemoembolizationofhepatocellularcarcinomaaccuracyandcorrelationwithresponse AT caoguang lipiodolretentionpatternassessedbyconebeamcomputedtomographyduringconventionaltransarterialchemoembolizationofhepatocellularcarcinomaaccuracyandcorrelationwithresponse AT wangxiao lipiodolretentionpatternassessedbyconebeamcomputedtomographyduringconventionaltransarterialchemoembolizationofhepatocellularcarcinomaaccuracyandcorrelationwithresponse AT chenhui lipiodolretentionpatternassessedbyconebeamcomputedtomographyduringconventionaltransarterialchemoembolizationofhepatocellularcarcinomaaccuracyandcorrelationwithresponse AT zhuxu lipiodolretentionpatternassessedbyconebeamcomputedtomographyduringconventionaltransarterialchemoembolizationofhepatocellularcarcinomaaccuracyandcorrelationwithresponse AT yangrenjie lipiodolretentionpatternassessedbyconebeamcomputedtomographyduringconventionaltransarterialchemoembolizationofhepatocellularcarcinomaaccuracyandcorrelationwithresponse AT wangxiaodong lipiodolretentionpatternassessedbyconebeamcomputedtomographyduringconventionaltransarterialchemoembolizationofhepatocellularcarcinomaaccuracyandcorrelationwithresponse |