Cargando…

Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T

BACKGROUND: T1 mapping based on cardiovascular magnetic resonance (CMR) is a novel approach using the magnetic relaxation T1 time as a quantitative marker for myocardial tissue composition. Various T1 mapping sequences are being used, with different strengths and weaknesses. Data comparing different...

Descripción completa

Detalles Bibliográficos
Autores principales: Teixeira, Tiago, Hafyane, Tarik, Stikov, Nikola, Akdeniz, Cansu, Greiser, Andreas, Friedrich, Matthias G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5050636/
https://www.ncbi.nlm.nih.gov/pubmed/27716344
http://dx.doi.org/10.1186/s12968-016-0286-6
_version_ 1782457920576815104
author Teixeira, Tiago
Hafyane, Tarik
Stikov, Nikola
Akdeniz, Cansu
Greiser, Andreas
Friedrich, Matthias G.
author_facet Teixeira, Tiago
Hafyane, Tarik
Stikov, Nikola
Akdeniz, Cansu
Greiser, Andreas
Friedrich, Matthias G.
author_sort Teixeira, Tiago
collection PubMed
description BACKGROUND: T1 mapping based on cardiovascular magnetic resonance (CMR) is a novel approach using the magnetic relaxation T1 time as a quantitative marker for myocardial tissue composition. Various T1 mapping sequences are being used, with different strengths and weaknesses. Data comparing different sequences head to head however are sparse. METHODS: We compared three T1 mapping sequences, ShMOLLI, MOLLI and SASHA in phantoms and in a mid-ventricular slice of 40 healthy individuals (mean age 59 ± 7 years, 45 % male) with low (68 %) or moderate cardiovascular risk. We calculated global and segmental T1 in vivo through exponential curve fitting and subsequent parametric mapping. We also analyzed image quality and inter-observer reproducibility. RESULTS: There was no association of T1 with cardiovascular risk groups. T1 however differed significantly depending on the sequence, with SASHA providing consistently higher mean values than ShMOLLI and MOLLI (1487 ± 36 ms vs. 1174 ± 37 ms and 1199 ± 28 ms, respectively; p < 0.001). This difference between sequences was much smaller in phantom measurements. In patients, segmental values were lower in the anterior wall for all sequences. Image quality, in general good for the steady-state-free-precession readouts in all sequences, was lower for SASHA parametric maps. On multivariate regression analysis, a longer T1 measured by MOLLI was correlated with lower ejection fraction and female gender. Inter-observer variability as assessed by intra-class correlation coefficients was excellent for all sequences (ShMOLLI: 0.995; MOLLI: 0.991; SASHA: 0.961; all p < 0.001). CONCLUSION: In a cross-sectional population with low to moderate cardiovascular risk, we observed a variation in T1 mapping results between inversion-recovery vs. saturation-recovery sequences in vivo, which were less evident in phantom images, despite a small interobserver variability. Thus, physiological factors, most likely related to B1 inhomogeneities, and tissue-specific properties, like magnetization transfer, that impact T1 values in vivo, render phantom validation insufficient, and have to be further investigated for a better understanding of the clinical utility of different T1 mapping approaches. TRIAL REGISTRATION: “Canadian Alliance For Healthy Hearts and Minds” – ClinicalTrials.gov NCT02220582; registered August 18, 2014.
format Online
Article
Text
id pubmed-5050636
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-50506362016-10-05 Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T Teixeira, Tiago Hafyane, Tarik Stikov, Nikola Akdeniz, Cansu Greiser, Andreas Friedrich, Matthias G. J Cardiovasc Magn Reson Research BACKGROUND: T1 mapping based on cardiovascular magnetic resonance (CMR) is a novel approach using the magnetic relaxation T1 time as a quantitative marker for myocardial tissue composition. Various T1 mapping sequences are being used, with different strengths and weaknesses. Data comparing different sequences head to head however are sparse. METHODS: We compared three T1 mapping sequences, ShMOLLI, MOLLI and SASHA in phantoms and in a mid-ventricular slice of 40 healthy individuals (mean age 59 ± 7 years, 45 % male) with low (68 %) or moderate cardiovascular risk. We calculated global and segmental T1 in vivo through exponential curve fitting and subsequent parametric mapping. We also analyzed image quality and inter-observer reproducibility. RESULTS: There was no association of T1 with cardiovascular risk groups. T1 however differed significantly depending on the sequence, with SASHA providing consistently higher mean values than ShMOLLI and MOLLI (1487 ± 36 ms vs. 1174 ± 37 ms and 1199 ± 28 ms, respectively; p < 0.001). This difference between sequences was much smaller in phantom measurements. In patients, segmental values were lower in the anterior wall for all sequences. Image quality, in general good for the steady-state-free-precession readouts in all sequences, was lower for SASHA parametric maps. On multivariate regression analysis, a longer T1 measured by MOLLI was correlated with lower ejection fraction and female gender. Inter-observer variability as assessed by intra-class correlation coefficients was excellent for all sequences (ShMOLLI: 0.995; MOLLI: 0.991; SASHA: 0.961; all p < 0.001). CONCLUSION: In a cross-sectional population with low to moderate cardiovascular risk, we observed a variation in T1 mapping results between inversion-recovery vs. saturation-recovery sequences in vivo, which were less evident in phantom images, despite a small interobserver variability. Thus, physiological factors, most likely related to B1 inhomogeneities, and tissue-specific properties, like magnetization transfer, that impact T1 values in vivo, render phantom validation insufficient, and have to be further investigated for a better understanding of the clinical utility of different T1 mapping approaches. TRIAL REGISTRATION: “Canadian Alliance For Healthy Hearts and Minds” – ClinicalTrials.gov NCT02220582; registered August 18, 2014. BioMed Central 2016-10-04 /pmc/articles/PMC5050636/ /pubmed/27716344 http://dx.doi.org/10.1186/s12968-016-0286-6 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Teixeira, Tiago
Hafyane, Tarik
Stikov, Nikola
Akdeniz, Cansu
Greiser, Andreas
Friedrich, Matthias G.
Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
title Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
title_full Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
title_fullStr Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
title_full_unstemmed Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
title_short Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T
title_sort comparison of different cardiovascular magnetic resonance sequences for native myocardial t1 mapping at 3t
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5050636/
https://www.ncbi.nlm.nih.gov/pubmed/27716344
http://dx.doi.org/10.1186/s12968-016-0286-6
work_keys_str_mv AT teixeiratiago comparisonofdifferentcardiovascularmagneticresonancesequencesfornativemyocardialt1mappingat3t
AT hafyanetarik comparisonofdifferentcardiovascularmagneticresonancesequencesfornativemyocardialt1mappingat3t
AT stikovnikola comparisonofdifferentcardiovascularmagneticresonancesequencesfornativemyocardialt1mappingat3t
AT akdenizcansu comparisonofdifferentcardiovascularmagneticresonancesequencesfornativemyocardialt1mappingat3t
AT greiserandreas comparisonofdifferentcardiovascularmagneticresonancesequencesfornativemyocardialt1mappingat3t
AT friedrichmatthiasg comparisonofdifferentcardiovascularmagneticresonancesequencesfornativemyocardialt1mappingat3t