Cargando…

The Prediction of Speech Recognition in Noise With a Semi-Implantable Bone Conduction Hearing System by External Bone Conduction Stimulation With Headband: A Prospective Study

Semi-implantable transcutaneous bone conduction devices are treatment options for conductive and mixed hearing loss (CHL/MHL). For counseling of patients, realistic simulation of the functional result is desirable. This study compared speech recognition in noise with a semi-implantable transcutaneou...

Descripción completa

Detalles Bibliográficos
Autores principales: Ihler, Friedrich, Blum, Jenny, Berger, Max-Ulrich, Weiss, Bernhard G., Welz, Christian, Canis, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5051673/
https://www.ncbi.nlm.nih.gov/pubmed/27698259
http://dx.doi.org/10.1177/2331216516669330
_version_ 1782458122066984960
author Ihler, Friedrich
Blum, Jenny
Berger, Max-Ulrich
Weiss, Bernhard G.
Welz, Christian
Canis, Martin
author_facet Ihler, Friedrich
Blum, Jenny
Berger, Max-Ulrich
Weiss, Bernhard G.
Welz, Christian
Canis, Martin
author_sort Ihler, Friedrich
collection PubMed
description Semi-implantable transcutaneous bone conduction devices are treatment options for conductive and mixed hearing loss (CHL/MHL). For counseling of patients, realistic simulation of the functional result is desirable. This study compared speech recognition in noise with a semi-implantable transcutaneous bone conduction device to external stimulation with a bone conduction device fixed by a headband. Eight German-language adult patients were enrolled after a semi-implantable transcutaneous bone conduction device (Bonebridge, Med-El) was implanted and fitted. Patients received a bone conduction device for external stimulation (Baha BP110, Cochlear) fixed by a headband for comparison. The main outcome measure was speech recognition in noise (Oldenburg Sentence Test). Pure-tone audiometry was performed and subjective benefit was assessed using the Glasgow Benefit Inventory and Abbreviated Profile of Hearing Aid Benefit questionnaires. Unaided, patients showed a mean signal-to-noise ratio threshold of 4.6 ± 4.2 dB S/N for speech recognition. The aided results were −3.3 ± 7.2 dB S/N by external bone conduction stimulation and −1.2 ± 4.0 dB S/N by the semi-implantable bone conduction device. The difference between the two devices was not statistically significant, while the difference was significant between unaided and aided situation for both devices. Both questionnaires for subjective benefit favored the semi-implantable device over external stimulation. We conclude that it is possible to simulate the result of speech recognition in noise with a semi-implantable transcutaneous bone conduction device by external stimulation. This should be part of preoperative counseling of patients with CHL/MHL before implantation of a bone conduction device.
format Online
Article
Text
id pubmed-5051673
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-50516732016-10-18 The Prediction of Speech Recognition in Noise With a Semi-Implantable Bone Conduction Hearing System by External Bone Conduction Stimulation With Headband: A Prospective Study Ihler, Friedrich Blum, Jenny Berger, Max-Ulrich Weiss, Bernhard G. Welz, Christian Canis, Martin Trends Hear Original Article Semi-implantable transcutaneous bone conduction devices are treatment options for conductive and mixed hearing loss (CHL/MHL). For counseling of patients, realistic simulation of the functional result is desirable. This study compared speech recognition in noise with a semi-implantable transcutaneous bone conduction device to external stimulation with a bone conduction device fixed by a headband. Eight German-language adult patients were enrolled after a semi-implantable transcutaneous bone conduction device (Bonebridge, Med-El) was implanted and fitted. Patients received a bone conduction device for external stimulation (Baha BP110, Cochlear) fixed by a headband for comparison. The main outcome measure was speech recognition in noise (Oldenburg Sentence Test). Pure-tone audiometry was performed and subjective benefit was assessed using the Glasgow Benefit Inventory and Abbreviated Profile of Hearing Aid Benefit questionnaires. Unaided, patients showed a mean signal-to-noise ratio threshold of 4.6 ± 4.2 dB S/N for speech recognition. The aided results were −3.3 ± 7.2 dB S/N by external bone conduction stimulation and −1.2 ± 4.0 dB S/N by the semi-implantable bone conduction device. The difference between the two devices was not statistically significant, while the difference was significant between unaided and aided situation for both devices. Both questionnaires for subjective benefit favored the semi-implantable device over external stimulation. We conclude that it is possible to simulate the result of speech recognition in noise with a semi-implantable transcutaneous bone conduction device by external stimulation. This should be part of preoperative counseling of patients with CHL/MHL before implantation of a bone conduction device. SAGE Publications 2016-10-03 /pmc/articles/PMC5051673/ /pubmed/27698259 http://dx.doi.org/10.1177/2331216516669330 Text en © The Author(s) 2016 http://creativecommons.org/licenses/by-nc/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Ihler, Friedrich
Blum, Jenny
Berger, Max-Ulrich
Weiss, Bernhard G.
Welz, Christian
Canis, Martin
The Prediction of Speech Recognition in Noise With a Semi-Implantable Bone Conduction Hearing System by External Bone Conduction Stimulation With Headband: A Prospective Study
title The Prediction of Speech Recognition in Noise With a Semi-Implantable Bone Conduction Hearing System by External Bone Conduction Stimulation With Headband: A Prospective Study
title_full The Prediction of Speech Recognition in Noise With a Semi-Implantable Bone Conduction Hearing System by External Bone Conduction Stimulation With Headband: A Prospective Study
title_fullStr The Prediction of Speech Recognition in Noise With a Semi-Implantable Bone Conduction Hearing System by External Bone Conduction Stimulation With Headband: A Prospective Study
title_full_unstemmed The Prediction of Speech Recognition in Noise With a Semi-Implantable Bone Conduction Hearing System by External Bone Conduction Stimulation With Headband: A Prospective Study
title_short The Prediction of Speech Recognition in Noise With a Semi-Implantable Bone Conduction Hearing System by External Bone Conduction Stimulation With Headband: A Prospective Study
title_sort prediction of speech recognition in noise with a semi-implantable bone conduction hearing system by external bone conduction stimulation with headband: a prospective study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5051673/
https://www.ncbi.nlm.nih.gov/pubmed/27698259
http://dx.doi.org/10.1177/2331216516669330
work_keys_str_mv AT ihlerfriedrich thepredictionofspeechrecognitioninnoisewithasemiimplantableboneconductionhearingsystembyexternalboneconductionstimulationwithheadbandaprospectivestudy
AT blumjenny thepredictionofspeechrecognitioninnoisewithasemiimplantableboneconductionhearingsystembyexternalboneconductionstimulationwithheadbandaprospectivestudy
AT bergermaxulrich thepredictionofspeechrecognitioninnoisewithasemiimplantableboneconductionhearingsystembyexternalboneconductionstimulationwithheadbandaprospectivestudy
AT weissbernhardg thepredictionofspeechrecognitioninnoisewithasemiimplantableboneconductionhearingsystembyexternalboneconductionstimulationwithheadbandaprospectivestudy
AT welzchristian thepredictionofspeechrecognitioninnoisewithasemiimplantableboneconductionhearingsystembyexternalboneconductionstimulationwithheadbandaprospectivestudy
AT canismartin thepredictionofspeechrecognitioninnoisewithasemiimplantableboneconductionhearingsystembyexternalboneconductionstimulationwithheadbandaprospectivestudy
AT ihlerfriedrich predictionofspeechrecognitioninnoisewithasemiimplantableboneconductionhearingsystembyexternalboneconductionstimulationwithheadbandaprospectivestudy
AT blumjenny predictionofspeechrecognitioninnoisewithasemiimplantableboneconductionhearingsystembyexternalboneconductionstimulationwithheadbandaprospectivestudy
AT bergermaxulrich predictionofspeechrecognitioninnoisewithasemiimplantableboneconductionhearingsystembyexternalboneconductionstimulationwithheadbandaprospectivestudy
AT weissbernhardg predictionofspeechrecognitioninnoisewithasemiimplantableboneconductionhearingsystembyexternalboneconductionstimulationwithheadbandaprospectivestudy
AT welzchristian predictionofspeechrecognitioninnoisewithasemiimplantableboneconductionhearingsystembyexternalboneconductionstimulationwithheadbandaprospectivestudy
AT canismartin predictionofspeechrecognitioninnoisewithasemiimplantableboneconductionhearingsystembyexternalboneconductionstimulationwithheadbandaprospectivestudy